Literature DB >> 36127611

Quantitation of Renin Activity in Plasma Using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS).

J Grace van der Gugten1,2, Daniel T Holmes3,4.   

Abstract

Accurate determination of plasma renin activity (PRA) is essential for the development and maintenance of an effective screening program for primary aldosteronism (PA). PRA measurement can also be useful in the investigation of renal artery stenosis, syndrome of mineralocorticoid excess, Addison's disease, congenital adrenal hyperplasia, Bartters and Gitelman syndromes, and for inherited defects in the renin angiotensin aldosterone system (RAAS). We describe a semiautomated and simple method for the accurate and precise measurement of PRA from 500 μL of plasma (250 μL if blank subtraction is omitted, as discussed) using a liquid chromatography and tandem mass spectrometry (LC-MS/MS) method for angiotensin I (AngI) in 96-well format. After a 3 h AngI generation step at 37 °C in buffering conditions at pH 6, the reaction is quenched with 10% formic acid containing AngI internal standard. Sample preparation then proceeds with offline solid phase extraction, two wash steps, and methanol elution followed by injection into the LC-MS/MS system. Quantitation is performed against a 7-point calibration linear curve prepared in buffer. The assay calibration range is 0.34-30.0 ng/mL, which corresponds to PRA values of 0.11-10.0 ng/mL/h: much wider than was possible using traditional competitive antibody-based methods. Total precision in clinical production has been observed to be 5.8-5.0% for BioRad Hypertension Control materials having nominal PRA values ranging from 1.73 to 12.43 ng/mL/h. At AngI concentrations of 0.06 ng/L (corresponding to a PRA of 0.02 ng/mL/h), signal-to-noise ratio is 50:1, indicating that the limit of quantitation is well below the level required for clinical use.
© 2022. The Author(s), under exclusive license to Springer Science+Business Media, LLC, part of Springer Nature.

Entities:  

Keywords:  Angiotensin I; Hypokalemia; Mass spectrometry; Mineralocorticoid hypertension; Plasma renin activity; Primary aldosteronism; Secondary hypertension

Mesh:

Substances:

Year:  2022        PMID: 36127611     DOI: 10.1007/978-1-0716-2565-1_39

Source DB:  PubMed          Journal:  Methods Mol Biol        ISSN: 1064-3745


  9 in total

1.  Plasma Renin Activity: The Importance of Correct Sample Type.

Authors:  Shannon Haymond; Nigel J Clarke; Richard E Reitz; Michael J McPhaul; Zengru Wu
Journal:  Clin Chem       Date:  2015-12-04       Impact factor: 8.327

Review 2.  Plasma renin and aldosterone measurements in low renin hypertensive states.

Authors:  Jean E Sealey; Richard D Gordon; Franco Mantero
Journal:  Trends Endocrinol Metab       Date:  2005-04       Impact factor: 12.015

3.  Reversible cryoactivation of recombinant human prorenin.

Authors:  T M Pitarresi; S Rubattu; R Heinrikson; J E Sealey
Journal:  J Biol Chem       Date:  1992-06-15       Impact factor: 5.157

4.  Radioimmunoassay of plasma renin activity.

Authors:  J E Sealey; J H Laragh
Journal:  Semin Nucl Med       Date:  1975-04       Impact factor: 4.446

Review 5.  Laboratory challenges in primary aldosteronism screening and diagnosis.

Authors:  Muhammad Rehan; Joshua E Raizman; Etienne Cavalier; Andrew C Don-Wauchope; Daniel T Holmes
Journal:  Clin Biochem       Date:  2015-01-22       Impact factor: 3.281

6.  A widely applicable plasma renin activity assay by LC-MS/MS with offline solid phase extraction.

Authors:  Laura J Owen; Joanne Adaway; Karen Morris; Stephen Lockhart; Brian G Keevil
Journal:  Ann Clin Biochem       Date:  2014-02-25       Impact factor: 2.057

7.  Plasma renin activity by LC-MS/MS: development of a prototypical clinical assay reveals a subpopulation of human plasma samples with substantial peptidase activity.

Authors:  Cory E Bystrom; Wael Salameh; Richard Reitz; Nigel J Clarke
Journal:  Clin Chem       Date:  2010-08-25       Impact factor: 8.327

8.  A liquid chromatography tandem mass spectrometry assay for plasma renin activity using online solid-phase extraction.

Authors:  S Carter; L J Owen; M N Kerstens; R P F Dullaart; B G Keevil
Journal:  Ann Clin Biochem       Date:  2012-09-27       Impact factor: 2.057

Review 9.  Activity assays and immunoassays for plasma Renin and prorenin: information provided and precautions necessary for accurate measurement.

Authors:  Duncan J Campbell; Juerg Nussberger; Michael Stowasser; A H Jan Danser; Alberto Morganti; Erik Frandsen; Joël Ménard
Journal:  Clin Chem       Date:  2009-03-05       Impact factor: 8.327

  9 in total