Purpose: Nowadays the Implantable Collamer Lens (ICL - STAAR Surgical. Monrovia. CA) is a refractive surgical technique offered not only when laser corneal correction is not possible but also when the patient requires premium quality indexes and when dry eye is a concern. The use of ICL phakic lenses in low myopic patients is an emanate factor to study and analyze in order to determine treatment predictability and stability in such patients. In this paper, we conducted a 1-year follow-up study on patients with myopia below -3.5D implanted with ICL lenses.Entities:
Keywords: low myopia; phakic intraocular low power lens; refractive surgery
Year: 2022 PMID: 36081600 PMCID: PMC9447455 DOI: 10.2147/OPTH.S373378
Source DB: PubMed Journal: Clin Ophthalmol ISSN: 1177-5467
Descriptive Statistics of Sample
| N=82 | Mean ± SD | Range |
|---|---|---|
| Age (years) | 35.06 ± 8.46 | 21 to 56 |
| UDVA (decimal) | 0.22 ± 0.15 | 0.00 to 0.60 |
| Sphere preop (D) | −1.94 ± 0.84 | −3.50 to +0.00 |
| Cyl Preop (D) | −1.21 ± 0.96 | 0.00 to −5.50 |
| SEQ Preop (D) | −2.34 ± 0.82 | −5.50 to −1.00 |
| CDVA preop (decimal) | 1.02 ± 0.10 | 0.75 to 1.25 |
| ACD preop (mm) | 3.24 ± 0.26 | 2.79 to 3.90 |
| WTW preop (mm) | 11.98 ± 0.33 | 11.20 to 12.60 |
| CCT preop (µm) | 543.32 ± 32.40 | 462 to 620 |
| IOP preop (mmHg) | 15.67 ± 2.76 | 9 to 23 |
| MeanK preop (D) | 43.52 ± 1.44 | 38.75 to 45.95 |
| ICL Sphere (D) | −3.04 ± 0.79 | −4.50 to −1.25 |
| Toric ICL Cyl (D) | 1.64 ± 0.64 | +0.50 to +3.00 |
Abbreviations: UDVA, uncorrected distance visual acuity; SEQ, spherical equivalent; D, diopters; CDVA, corrected distance visual acuity; ACD, anterior chamber depth; WTW, white-to-white distance; CCT, central corneal thickness; IOP, intraocular pressure.
Refractive and Visual Outcomes at 1, 6 and 12 Months after Surgery
| N=82 | 1 Month | 6 Months | 12 Months | p value |
|---|---|---|---|---|
| Mean ± SD | Mean ± SD | Mean ± SD | ||
| UDVA (decimal) | 1.09 ± 0.18 (0.55 to 1.50) | 1.07 ± 0.13 (0.75 to 1.25) | 1.07 ± 0.14 (0.75 to 1.25) | >0.05 |
| Sphere (D) | −0.01 ± 0.14 (−0.75 to 0.50) | −0.03 ± 0.13 (−0.75 to 0.00) | −0.02 ± 0.12 (−0.50 to +0.25) | >0.05 |
| Cylinder (D) | −0.05 ± 0.15 (−0.75 to 0.00) | −0.07 ± 0.21 (−0.75 to 0.00) | −0.02 ± 0.18 (−0.50 to 0.75) | >0.05 |
| Spherical equivalent (D) | −0.04 ± 0.15 (−0.75 to 0.13) | −0.07 ± 0.16 (−0.75 to 0.00) | −0.03 ± 0.16 (−0.75 to +0.38) | >0.05 |
| CDVA (decimal) | 1.09 ± 0.14 (0.55 to 1.50) | 1.07 ± 0.12 (0.80 to 1.25) | 1.09 ± 0.13 (0.80 to 1.25) | >0.05 |
| Vault (microns) | 573.33 ± 239.77 (150 to 1204)† | 544.67 ± 260.98 (0 to 1210)‡ | 513.78 ± 262.87 (0 to 1180)§ | * |
| IOP (mmHg) | 15.68 ± 2.68 (10 to 22) | 15.17 ± 2.69 (10 to 21) | 15.63 ± 2.17 (11 to 21) | >0.05 |
| Efficacy Index | 1.07 ± 0.17 (0.58 to 1.50) | 1.06 ± 0.14 (0.75 to 1.33) | 1.07 ± 0.15 (0.75 to 1.33) | >0.05 |
| Security Index | 1.09 ± 0.17 (0.58 to 1.50) | 1.07 ± 0.12 (1.00 to 1.33) | 1.09 ± 0.13 (0.83 to 1.33) | >0.05 |
Notes: *Mean Vault p value: †1 month–6-months p=0.009; §1 month–12 months p=0.0010; ‡6 months–12 months p=0.191.
Figure 1Mean spherical equivalent and cylinder predictability at 12 months. R2 = 0.965 and 0.928 for SEQ and CYL, respectably.
Figure 2Vault evolution, and vault correlation between vault measurement at 1 month and at 12 months.
Figure 3Refractive stability at 12-month follow-up.