Ana Mallo-López1,2,3, Pilar Fernández-González4, Patricia Sánchez-Herrera-Baeza4, Alicia Cuesta-Gómez4, Francisco Molina-Rueda4, Ángela Aguilera-Rubio3.
Abstract
BACKGROUND: Improving balance remains a challenge in stroke rehabilitation. The technological development has allowed the design of more accessible and user-friendly systems for assessing postural control.Entities:
Keywords: assessment; balance; devices; postural control; stroke; technology
Mesh:
Year: 2022 PMID: 36078665 PMCID: PMC9517772 DOI: 10.3390/ijerph191710948
Source DB: PubMed Journal: Int J Environ Res Public Health ISSN: 1660-4601 Impact factor: 4.614
Figure 1Flow chart.
Summary of the results.
| Author | Type of Study | Sample Characteristics | Outcome Measures | Type of Device |
|---|---|---|---|---|
| Choi et al. (2021) [ | RCT | Chronic stroke (N = 24) | BBT | BIORescue (analysis system by biofeedback, RM INGENIERIE, Rodez, France) |
| Choi et al. (2020) [ | RCT | Chronic stroke (N = 36) | PASS | BIORescue (analysis system by biofeedback, RM INGENIERIE, Rodez, France) |
| Maguire et al. (2020) [ | CT | Chronic stroke (N = 4) | FGA | SwayStar Balance System: two angular velocity sensors |
| Choi et al. (2019) [ | RCT | Chronic stroke (N = 24) | TUG | BIORescue (analysis system by biofeedback, RM INGENIERIE, Rodez, France) |
| Sahin et al. (2019) [ | CT | Chronic stroke (N = 50) | BESTest | Biodex-BioSway Balance System (SD 950-340, Biodex Medical Systems, Inc., Shirley, NY, USA) |
| van Meulen et al. (2016) [ | CT | Chronic stroke (N = 13) | BBT | Xsens ForceShoes™ (Xsens Technologies B.V., Enschede, The Netherlands) additionally equipped with |
| Afzal et al. (2015) [ | CT | Chronic stroke (N = 8) | Trunk tilt angles | Smartphone application |
* Median (25–75 IQR, interquartile range); CT: Clinical trial; RCT: Randomized clinical trial; CG: Control group; IG: Intervention group; PG: Paretic group; NPG: Non-paretic group; St: Stick; AFO: Ankle foot orthosis; OS: Orthopedic shoes; M: Male; F: Female; PASS: Postural Assessment Scale for Stroke; BBT: Berg Balance Test; TUG: Time Up and Go test; COP: Center of pressure; COL: Center of loading; LOS: Limit of stability; FGA: Functional Gait Assessment; ABC: Activities-Specific Balance Confidence Scale; PST: Postural Stability Test; MSOT: Modified Sensory Organization Test; COM: Center of mass; TB: Tinetti Balance test; FM: Fugl–Meyer.
PEDro scale.
| Ítem | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | Total |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Author-Year | ||||||||||||
| Choi et al. (2021) [ | - | 1 | 1 | 1 | 0 | 0 | 1 | 1 | 1 | 1 | 1 | 8/11 |
| Choi et al. (2020) [ | - | 1 | 1 | 1 | 0 | 0 | 1 | 1 | 1 | 1 | 1 | 8/11 |
| Maguire et al. (2020) [ | - | 1 | 0 | 0 | 0 | 0 | 0 | 1 | 1 | 1 | 1 | 5/11 |
| Choi et al. (2019) [ | - | 1 | 1 | 1 | 0 | 1 | 1 | 1 | 1 | 1 | 1 | 9/11 |
| Sahin et al. (2019) [ | - | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 1 | 1 | 1 | 4/11 |
| Van Meulen et al. (2016) [ | - | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 1 | 1 | 1 | 4/11 |
| Afzal et al. (2015) [ | - | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 1 | 1 | 1 | 4/11 |
Scoring: 0 = the assessment criterion is not achieved; 1 = the evaluation criterion is achieved.
Clinical utility of the selected measurement tools.
| Measurement Tool | Time | Cost | Specialist Equipment | Portability | Total (Max = 10) |
|---|---|---|---|---|---|
| BIORescue | 3 | 0 | 1 | 2 | 6 |
| SwayStar Balance System | 3 | 0 | 2 | 2 | 7 |
| Biodex-BioSway Balance System | 3 | 0 | 1 | 1 | 5 |
| Xsens ForceShoesTM | 3 | 0 | 2 | 2 | 7 |
| Smarthphone | 3 | 3 | 2 | 2 | 10 |
Oxford Scale.
| Article | Level of Evidence | Level of Recommendation |
|---|---|---|
| Choi et al. (2021) [ | 2b | B |
| Choi et al. (2020) [ | 1b | A |
| Maguire et al. (2020) [ | 4 | C |
| Choi et al. (2019) [ | 2b | B |
| Sahin et al. (2019) [ | 2b | B |
| Van Meulen et al. (2016) [ | 4 | C |
| Afzal et al. (2015) [ | 3b | B |
Figure 2Risk of bias [24,25,26,27,28,29,30].