Literature DB >> 3606263

Disc immobilization of Björk-Shiley and Medtronic Hall valves during and immediately after valve replacement.

G P Pai, R G Ellison, J W Rubin, H V Moore, M V Kamath.   

Abstract

During the last fourteen years, 377 unileaflet tilting-disc prosthetic valves (Björk-Shiley and Medtronic Hall) have been used for single or multiple valve replacements with and without concomitant coronary artery by-pass grafting. In the past five years, five instances of disc immobilization (three in the mitral and two in the aortic position) occurred either at the time of weaning from cardiopulmonary bypass or immediately thereafter. When the implanted site of the prosthetic valve was the mitral position, reexploration in 2 patients revealed chordal remnants in the subannular area stuck between the disc occluder and the valve ring, thereby immobilizing the disc. In the third instance, the free movement of the disc was impeded by the left ventricular myocardium. In the aortic position, an unraveled suture impacted between the disc occluder and the valve ring immobilized the disc in 1 patient. In the other patient, the cause of the malfunction could not be determined at the time of reexploration. The 1 death among these 5 patients was directly related to the malfunction of the prosthesis. The mechanism, recognition, treatment, and prevention of this catastrophic malfunction of tilting-disc valves are discussed.

Entities:  

Mesh:

Year:  1987        PMID: 3606263     DOI: 10.1016/s0003-4975(10)62361-2

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  6 in total

1.  Pressure damping, a "billowing" septum, and an eerie silence: perioperative, intermittent obstruction of a mitral valve prosthesis.

Authors:  W Keeble; S M Cobbe
Journal:  Heart       Date:  2000-09       Impact factor: 5.994

Review 2.  Dynamics of proteins in Golgi membranes: comparisons between mammalian and plant cells highlighted by photobleaching techniques.

Authors:  T H Ward; F Brandizzi
Journal:  Cell Mol Life Sci       Date:  2004-01       Impact factor: 9.261

3.  [Mechanical versus biological heart valves].

Authors:  J Ennker; A Lauruschkat
Journal:  Z Kardiol       Date:  2001-12

4.  Obstruction of mechanical mitral valves by preserved posterior leaflet remnants.

Authors:  Ugur Coskun; Onur Baydar; Gurkan Cetin; Mehmet Serdar Kucukoglu
Journal:  J Echocardiogr       Date:  2012-11-11

Review 5.  [Heart valve and myocardial tissue engineering].

Authors:  Serghei Cebotari; Igor Tudorache; Tobias Schilling; Axel Haverich
Journal:  Herz       Date:  2010-08       Impact factor: 1.443

6.  Aortic valve replacement with 31- and 33-mm mechanical prostheses: early results.

Authors:  Gaurav Gupta; Ambuj Roy; A Sampath Kumar
Journal:  Tex Heart Inst J       Date:  2004
  6 in total