Literature DB >> 3606257

Transthoracic intraaortic balloon pump support: experience in 39 patients.

W McGeehin, F Sheikh, J S Donahoo, M J Lechman, H MacVaugh.   

Abstract

From June, 1982, through July, 1985, 39 (1.5%) of 2,570 patients undergoing open-heart procedures required insertion of a transthoracic intraaortic balloon pump (IABP). In all of these patients, a percutaneous attempt failed or was contraindicated. There were 24 (62%) men and 15 (38%) women. The mean age was 64.9 years. Five patients (13%) sustained complications potentially related to the transthoracic IABP. They included mediastinal infection in 1 patient (2.5%), balloon rupture in 2 patients (5%), and cerebrovascular accidents in 4 patients (10%). The overall survival was 44%. Survival for the group of patients weaned from transthoracic IABP support was 17 (81%) of 21. There were no deaths directly related to the transthoracic IABP. The transthoracic IABP was removed under local anesthesia without sternotomy in 19 (90%) of the patients weaned and with formal sternotomy in the remaining 2 (9%). In a select group of patients requiring intraaortic balloon counterpulsation, the use of the transthoracic IABP is a reasonable second choice for patients in whom other methods of balloon support are not feasible.

Entities:  

Mesh:

Year:  1987        PMID: 3606257     DOI: 10.1016/s0003-4975(10)62350-8

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  6 in total

1.  Coronary artery revascularization concomitant with vascular surgery.

Authors:  T Isomura; K Hisatomi; N Hayashida; T Sato; H Maruyama; K Yamana; K Kosuga; S Aoyagi
Journal:  Surg Today       Date:  1997       Impact factor: 2.549

2.  Trans-aortic counterpulsation: a viable alternative?

Authors:  Bharat Datt; Lisa Hutchison; Charles Peniston
Journal:  J Extra Corpor Technol       Date:  2007-06

3.  Six years' experience with closed-chest decannulation of transthoracically inserted cardiac-assist balloon catheters.

Authors:  F Robicsek
Journal:  Tex Heart Inst J       Date:  1992

Review 4.  Retained intraaortic balloon. Case report and review of the literature.

Authors:  A M Grande; L Martinelli; A Graffigna; M Viganò
Journal:  Tex Heart Inst J       Date:  1995

Review 5.  Intra aortic balloon pump: literature review of risk factors related to complications of the intraaortic balloon pump.

Authors:  Haralabos Parissis; Alan Soo; Bassel Al-Alao
Journal:  J Cardiothorac Surg       Date:  2011-11-02       Impact factor: 1.637

6.  Transaortic intra-aortic balloon pump catheter insertion through a separate saphenous vein graft in patients with severe aortoiliac disease.

Authors:  Faruk Toktas; Senol Yavuz; Cuneyt Eris; Suleyman Surer
Journal:  ScientificWorldJournal       Date:  2014-01-02
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.