Literature DB >> 17672190

Trans-aortic counterpulsation: a viable alternative?

Bharat Datt1, Lisa Hutchison, Charles Peniston.   

Abstract

Transthoracic intra-aortic balloon pump (IABP) insertion has been a relatively rare and uncommon procedure. However, it is an established beneficial option in patients with severe peripheral vascular disease (PVD) accompanied with bi-lateral femoral arterial occlusion. There are several viable alternatives to trans-aortic IABP insertion, including trans-axillary or in abdominal aorta (requiring a laparotomy). Cardiac surgery has the advantage of an open sternum, facilitating effortless direct intra-aortic balloon (IAB) insertion into the aorta. The IAB can be inserted either through a 9-mm graft or directly into the ascending aorta. During cardiac surgery, direct insertion into the ascending aorta with the balloon tip lying distally in the abdominal aorta is facilitated with an open sternum. The base of the balloon lies approximately 2 cm below the left subclavian and can be confirmed through a trans-esophageal echocardiogram (TEE). Elimination of a graft insertion saves the team from time-consuming maneuvers and additional hemorrhagic complications. In our experience, postoperative vasoplegic syndrome coupled with myocardial edema contributed to patent instability and was treated with vasopressin and transthoracic IAB insertion. The CS 100 (Datascope Corp., Mahwah, NJ) console allowed the ability to time the balloon accurately. This case report details our experience with one such patient and establishes trans-aortic counter-pulsation as a safe and viable option in patients with severe PVD, where percutaneous insertion is precluded or has failed.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17672190      PMCID: PMC4680673     

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  10 in total

1.  Transthoracic intra-aortic balloon pump in open heart operations: techniques and outcome.

Authors:  O E Arafa; O R Geiran; J L Svennevig
Journal:  Scand Cardiovasc J       Date:  2001-02       Impact factor: 1.589

2.  The hemodynamic effects of methylene blue when administered at the onset of cardiopulmonary bypass.

Authors:  Andrew D Maslow; Gary Stearns; Parag Butala; Parag Batula; Carl S Schwartz; Jeffrey Gough; Arun K Singh
Journal:  Anesth Analg       Date:  2006-07       Impact factor: 5.108

3.  Intraoperative placement of the percutaneous intraaortic balloon pump through the ascending aorta.

Authors:  K N Melvin; B S Goldman
Journal:  Ann Thorac Surg       Date:  1982-06       Impact factor: 4.330

4.  Vasoplegic syndrome after off-pump coronary artery bypass surgery: an unusual complication.

Authors:  Shahzad G Raja; Gilles D Dreyfus
Journal:  Tex Heart Inst J       Date:  2004

5.  Transthoracic intraaortic balloon pump support: experience in 39 patients.

Authors:  W McGeehin; F Sheikh; J S Donahoo; M J Lechman; H MacVaugh
Journal:  Ann Thorac Surg       Date:  1987-07       Impact factor: 4.330

6.  Vasoplegic syndrome after open heart surgery.

Authors:  W J Gomes; A C Carvalho; J H Palma; C A Teles; J N Branco; M G Silas; E Buffolo
Journal:  J Cardiovasc Surg (Torino)       Date:  1998-10       Impact factor: 1.888

7.  Methylene blue reduces mortality and morbidity in vasoplegic patients after cardiac surgery.

Authors:  Ricardo L Levin; Marcela A Degrange; Gustavo F Bruno; Carlos D Del Mazo; Daniel J Taborda; Jorge J Griotti; Fernando J Boullon
Journal:  Ann Thorac Surg       Date:  2004-02       Impact factor: 4.330

8.  Experience in 100 transthoracic balloon pumps.

Authors:  S R Hazelrigg; J E Auer; P E Seifert
Journal:  Ann Thorac Surg       Date:  1992-09       Impact factor: 4.330

9.  Juxtaaortic counterpulsation: comparison with intraaortic counterpulsation in an animal model of acute heart failure.

Authors:  Edmundo I Cabrera Fischer; Eduardo de Forteza; Marcelo R Risk; Guido A Nicolini; Juan M Camus; Franco M Pessana
Journal:  ASAIO J       Date:  2004 Jul-Aug       Impact factor: 2.872

10.  Transascending aortic intraaortic balloon insertion with delayed sternal closure: A retrospective analysis.

Authors:  Clement C. Ugorji; Stephen A. Turner; Michael G. McGee; Thomas M. Fuhrman; Denton A. Cooley; John C. Norman
Journal:  Cardiovasc Dis       Date:  1980-09
  10 in total
  2 in total

1.  Anatomical advantage to percutaneous insertion of the intra-aortic balloon through the left brachial artery over the right brachial artery.

Authors:  Bharat Datt; Steve Miner
Journal:  J Extra Corpor Technol       Date:  2013-03

2.  Transaortic intra-aortic balloon pump catheter insertion through a separate saphenous vein graft in patients with severe aortoiliac disease.

Authors:  Faruk Toktas; Senol Yavuz; Cuneyt Eris; Suleyman Surer
Journal:  ScientificWorldJournal       Date:  2014-01-02
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.