Biomechanical comparative analysis of effects of dynamic and rigid fusion on lumbar motion with different sagittal parameters: An in vitro study.

Wei Wang1,2, Chao Kong1,2, Fumin Pan1,2, Yu Wang1,2, Xueqing Wu3, Baoqing Pei3, Shibao Lu1,2.   

Abstract

Background: Although the management of the lumbar disease is highly dependent on the severity of the patient's condition, optimal surgical techniques to reduce the risk of adjacent degeneration disease (ADS) remain elusive. Based on in vitro biomechanical tests of the cadaver spine, this study aimed to comparatively analyze the kinematic responses of the spine with dynamic and rigid fixations (i.e., Coflex fixation and posterolateral fusion) after single-or double-level lumbar fusion in daily activities.
Methods: Six human lumbar specimens (L1-S1) were selected for this experiment, and the sagittal parameters of each lumbar specimen were measured in the 3D model. The specimens were successively reconstructed into five groups of models: intact model, single-level L4-5 Coflex fixation model, single-level L4-5 Fusion (posterior pedicle screw fixation) model, double-level L4-5 Coflex + L5-S1 Fusion model; and double-level L4-5 Fusion + L5-S1 Fusion model. The pure moment was applied to the specimen model to simulate physiological activities in daily life through a custom-built robot testing device with an optical tracking system.
Results: For single-level lumbar fusion, compared to the traditional Fusion fixation, the Coflex dynamic fixation mainly restricted the extension of L4-L5, partially retained the range of motion (ROM) of the L4-L5 segment, and reduced the motion compensation of the upper adjacent segment. For the double-level lumbar fixation, the ROM of adjacent segments in the Coflex + Fusion was significantly decreased compared to the Fusion + Fusion fixation, but there was no significant difference. In addition, PT was the only sagittal parameter of the preoperative lumbar associated with the ROM under extension loading. The Coflex fixation had little effect on the original sagittal alignment of the lumbar spine.
Conclusion: The Coflex was an effective lumbar surgical technique with a less altering kinematic motion of the lumbar both at the index segment and adjacent segments. However, when the Coflex was combined with the fusion fixation, this ability to protect adjacent segments remained elusive in slowing the accelerated degradation of adjacent segments.
Copyright © 2022 Wang, Kong, Pan, Wang, Wu, Pei and Lu.

Entities:  

Keywords:  Coflex interspinous stabilization; adjacent segment degeneration; lumbar fusion; range of motion; sagittal parameter

Year:  2022        PMID: 36061438      PMCID: PMC9437262          DOI: 10.3389/fbioe.2022.943092

Source DB:  PubMed          Journal:  Front Bioeng Biotechnol        ISSN: 2296-4185


Introduction

Lumbar fusion with posterior instrumentation has been the gold standard for lumbar spine intervention treatment. Traditional lumbar fusion has intrinsic issues in some cases, such as longer operational time, higher blood loss, and greater stiffness, and may result in over-treatment of the patient. The longitudinal retrospective investigation of lumbar fusion, on the other hand, found that rigid fixation accelerated secondary degeneration of adjacent segments (Whitecloud et al., 1994; Louie et al., 2019; Wang et al., 2021). Spine fusions disrupt the mechanical environment inside the vertebral body, affect blood oxygen and nourishment delivery, and cause postoperative complications of adjacent segments after spinal fusion (Zhou et al., 2016). The high incidence of secondary accelerated degenerative diseases at adjacent levels after lumbar fusion is still a problem for orthopedic surgeons. To overcome the limits of traditional fusion, emerging non-fusion techniques with motion preservation are designed to achieve sufficient stability and slow the degeneration process by restoring partially segmental kinematics, allowing for more physiological load transmission (Sangiorgio et al., 2011; Zhou et al., 2020; Zheng et al., 2021). A Coflex interspinous stabilization, as the third joint offloads the two facets, provides neutral equilibrium of lumbar disorders and minimizes stress concentration in adjacent segments, preventing the occurrence of ASD. Several previous studies have suggested that the Coflex system is safe and effective (Zhao et al., 2018; Shen et al., 2021). Zheng et al. (2021) compared the radiographic outcomes of patients after single-level Coflex stabilization and traditional posterior fusion for a minimum of 8 years and found no significant difference between the two groups at each time point. The superiority of that dynamic, flexible surgical stabilization over traditional fusions, however, remains elusive, especially considering that the selection of surgery is highly dependent on the severity of the patient’s condition. The key to maintaining the static and dynamic balance of the human body is sagittal spine alignment, which minimizes the energy consumption of the trunk in daily activities. Clinical studies have suggested that sagittal balance is important in developing therapeutic strategies for a variety of spinal disorders (Ferrero et al., 2016; Sebaaly et al., 2018; Sebaaly et al., 2020). Spinopelvic radiographs have gradually become the standard in clinic for giving information on pathological diagnosis or preoperative planning (Roussouly et al., 2005; Bari et al., 2020; Sebaaly et al., 2020). Roussouly et al. (2005) proposed four types of sagittal alignment of the normal spine, which was defined by several sagittal parameters of the lumbar spine, such as pelvic incidence (PI), sacral inclination (SS), pelvic tilt (PT), lumbar lordosis (LL), etc. The optimum spinal surgery treatment should alleviate focal segmental illness and restore lumbar spine stability. Simultaneously, surgical procedures aim to minimize the impact on the overall biomechanical stability of the lumbar spine, especially in adjacent segments. Many patients with lumbar degeneration have some degree of movement instability and obstacles (Kettler et al., 2012; Pieler-Bruha, 2016). The in vivo and in vitro kinematic study of the human spine is still a challenging task. There have been few studies on assessing the effect of dynamic or rigid fixation on spinal motion on a laboratory platform considering the sagittal alignment of the spine due to a shortage of human donor cadaver spines and complicated experimental procedures. The goal of this study was to establish an experimental assessment method for spinal biomechanics research after lumbar fusion, considering spinal kinematics and sagittal alignment. We investigated how the dynamic Coflex and traditional fusions and fixed segments (single or double-level lumbar fusion) influenced the range of motion (ROM) of the lumbar, especially on adjacent segments. This study also tried to find out whether normal sagittal parameters before fusion correlated with the ROM of the spine after different lumbar fusions. These results partially bridged the gap in understanding the biomechanical response of the spine to dynamic and traditional fixation devices and provide references for understanding the accelerated degeneration of adjacent segments and optimizing the application of spinal internal fixation.

Materials and methods

Specimen preparation

Approved by the Bioethics and Medical Ethics Committee, Beihang University (No.: BM20190009), Six donated human lumbar spines (L1–S1 segments, three females, three males, 32–64 years of age) were enrolled in the experimental study. The spiral computed tomography (CT) with a slice thickness of 0.6 mm (Light Speed Pro16, GE, Waukesha, WI, United States) was conducted to exclude the lumbar spines with disc degeneration, bony defects, scoliosis, tumors, a history of back surgery, or prolonged bed rest before death. Muscles around the lumbar spine were removed to gain the osteoligamentous structure, but be careful to preserve discs, facets and ligaments (Wilke et al., 1998). The specimens were partially frozen and wrapped in cling film before testing to reduce water loss.

Parameters measurement

A 3D model of the lumbar was reconstructed using CT images to measure the sagittal parameters. Duval-Beaupère et al. (1992), Roussouly et al. (2005) defined sagittal parameters. The lumbo-pelvic sagittal parameters included pelvic incidence (PI), sacral slope (SS), pelvic tilt (PT), lumbar lordosis (LL), the apex of lordosis (Apex), lumbar title angle (LTA), upper_arc, and the number of vertebrae in lordosis (NVL), as shown in Figure 1. The five observers measured each radiograph twice with 1 week between rounds.
FIGURE 1

Measurement of sagittal parameters in the 3D lumbo-pelvic model.

Measurement of sagittal parameters in the 3D lumbo-pelvic model.

Construction of the lumbar fusion model

Each specimen was successively reconstructed into five groups of models, as shown in Figure 2. 1) Normal: intact model; 2) L4-L5 Coflex: single-level L4-5 Coflex fixation model; 3) L4-L5 Fusion: single-level L4-5 pedicle screw fixation model; 4) Coflex + Fusion: double-level L4-5 Coflex + L5-S1 pedicle screw fixation model; 5) Fusion + Fusion: double-level L4-5 Coflex™ + L5-S1 pedicle screw fixation model. All the above models were made by experienced orthopedic doctors in Xuanwu Hospital.
FIGURE 2

Schematic diagram of the in vitro experimental sample. (A) Normal; (B) L4-L5 Coflex; (C) L4-L5 Fusion; (D) Coflex + Fusion (L4-L5 Coflex + L5-S1 Fusion); (E) Fusion + Fusion (L4-L5 Fusion + L5-S1 Fusion). There were six samples in each group. (F) Implanted devices; (G) the robotic testing device; (H) 3D optoelectronic camera system.

Schematic diagram of the in vitro experimental sample. (A) Normal; (B) L4-L5 Coflex; (C) L4-L5 Fusion; (D) Coflex + Fusion (L4-L5 Coflex + L5-S1 Fusion); (E) Fusion + Fusion (L4-L5 Fusion + L5-S1 Fusion). There were six samples in each group. (F) Implanted devices; (G) the robotic testing device; (H) 3D optoelectronic camera system.

Testing protocol and device

A robotic testing device (NX100MH6, Kabushiki-gaisha Yasukawa Denki, Kitakyushu, Japan) published in our previous literature was performed to measure the force-displacement behavior of lumbar segments (Kong et al., 2015) (Figure 2). A force-moment sensor (Gamma, ATI Industrial Automation, Ontario, Canada) was mounted on the robot’s arm to record force and then provide feedback. Polymethylmethacrylate (PMMA) was used to fix both the L1 and S1 vertebra ends for installation in the custom-made containers (Figure 2). The 3D optoelectronic camera system (Optotrak Certus, Northern Digital Inc., Waterloo, Canada) recorded the vertebrae movement by tracking the location of five markers. The markers were attached to L1, L2, L3, L4, and L5 vertebrae, respectively. According to the International Society of Biomechanics (ISB), the coordinating axes between adjacent vertebral bodies as shown in Figure 3. The test protocol consisted of six pure moment loads at a constant loading rate of 1.0°/s (Panjabi et al., 1992), including the flexion and extension load of 7.5 Nm, a lateral bending load of 7.5 Nm and axial rotation of 5 Nm. The robotic system automatically optimized the loading path, increasing the target load by 10% (7.5/5 Nm). In order to minimize the viscoelastic effect (Panjabi, 1998; Panjabi, 2007), the first 1.5 loading cycles were used and the following three loading cycles were recorded for analysis. During the test, the specimens were kept moist with saline (0.9%). First, Normal specimens were tested using the above method and then soaked in 0.9% saline water for 30 min. The normal specimen was implanted with the Coflex at the L4-5 segment to reconstruct the L4-5 Coflex specimen. The L4-5 Coflex specimen then repeated the above experimental steps and recovered. Similarly, L4-L5 Fusion, Coflex + Fusion, and Fusion + Fusion specimens were sequentially reconstructed and tested. In this study, the same spine specimen was reused five times. O’Connell et al. (2007) demonstrated that, in the in vitro tests, the original mechanical properties of the spine could be restored when soaking in a physiological saline bath for 3–4 times longer than the loading time.
FIGURE 3

The coordinate system of two adjacent vertebral bodies.

The coordinate system of two adjacent vertebral bodies.

Data analysis

Data analysis was performed using SPSS software (IBM Corp, Armonk, NY, United States). Inter-rater and intra-rater reliability was assessed using intra-class correlation (ICC) coefficients. The ROM of the specimens in all the groups was measured under different loading conditions. Paired t-tests were used to compare the ROM of the same specimens in the different model groups. Spearman’s correlations were used to compare the relationships between the sagittal parameters and the ROM in the different Model groups under all loading conditions. Correlations were assumed to be strong (r = 0.80–1.00), moderate (r = 0.50–0.79), weak (r = 0.20–0.49), or not relevant (r < 0.20). p < 0.05 was considered statistically significant.

Results

Sagittal parameters

The sagittal parameters of the intact specimens before fusion were shown in Table 1. The average value of LL, PI, PT SS, Upper_arc and LTA was 46.88 ± 7.74°, 10.67 ± 0.92°, 36.22 ± 7.06°, 49.37 ± 6.18°, 14.90 ± 0.91°, and −4.75 ± 0.97°, respectively. The inflection point from kyphosis to lordosis almost appeared at the T12-L1 segments with an NVL of 5.01. The Apex of lumbar lordosis was located near the lower endplate L3 to the upper endplate S1. The ICC of all the parameters ranged from 0.83 to 0.97.
TABLE 1

Sample information.

SexAgePI (°)PT (°)SS (°)LL (°)Upper arc (°)LTA (°)ApexNVL
Sample 1Female5336.99.427.540.314−5.2Upper L54.3
Sample 2Male3239.610.229.443.213.9−4.4Base L44.6
Sample 3Male5544.211.432.848.215.4−4.2Base L44.9
Sample 4Female6447.510.137.452.414.8−5.7Middle L45
Sample 5Male5954.110.743.453.914.7−5.9Middle L44.8
Sample 6Female425912.246.858.216.6−3.07Base L35
Sample information.

Overall range of motion in a single-level lumbar fixation model

Under different loading conditions, the overall ROM of L1-S1 segments in the two single-level lumbar fixation models (L4-L5 Coflex and L4-L5 Fusion) was shown in Figure 4. The overall ROM change in the L4-5 Coflex was minimal, essentially less than 0.3°. As shown in Table 2, the single-level Coflex fixation had a significant effect on the ROM in flexion and extension (p < 0.05), compared to the ROM in the Normal, but there was no significant change in the ROM in lateral bending and axial rotation loading (p > 0.05). For the L4-L5 Fusion model, the overall ROM decreased significantly under all loading conditions (p < 0.05). The ROM decreased from 1.19° to 2.91° in flexion, 0.13°–1.16° in extension, 0.60°–2.37° in lateral bending, and 0.61°–3.31° in axial rotation, respectively. The L4-L5 Fusion had a larger effect on the ROM than the L4-L5 Coflex in flexion, lateral bending, and axial rotation (p < 0.05). Although the decrease in ROM in the L4-L5 Fusion was larger than that in the L4-L5 Coflex under extension loading, there was no significant difference between them (p > 0.05).
FIGURE 4

Preoperative and postoperative differences in the overall range of motion of each specimen. C: L4-L5 Coflex fixation group; F: L4-L5 Fusion fixation group.

TABLE 2

Significant difference in the range of motion of single-level fusion under different loading.

Normal VS. L4-L5 CoflexNormal VS. L4-L5 FusionL4-L5 Coflex VS. L4-L5 Fusion
Flexion0.036*0.001*0.003*
Extension0.006*0.022*0.052
Left-bending0.1520.005*0.007*
Right-bending0.3880.007*0.01*
Left-rotation0.930.002*0.003*
Right-rotation0.540.001*0.001*

*Significant difference p < 0.05.

Preoperative and postoperative differences in the overall range of motion of each specimen. C: L4-L5 Coflex fixation group; F: L4-L5 Fusion fixation group. Significant difference in the range of motion of single-level fusion under different loading. *Significant difference p < 0.05.

Intervertebral rotation distribution in a single-level fixation model

The distribution of the ROM of each vertebra in the L4-L5 Coflex and L4-L5 Fusion was shown in Figure 5. The Coflex dynamic fixation reduced ROM from 36.71% to 55.68% in extension, 17.73%–28.61% in flexion, and about 10% in lateral bending and axial rotation at the L4-L5 level. The increase in ROM in adjacent segments of the specimens after L4-L5 Coflex was minimal, ranging from 0.06% to 14.19%. In extension, the increase in ROM of adjacent segments was significantly greater than that under other loading conditions, indicating that the Coflex implant greatly inhibited extension movement. In the L4-L5 Fusion, the ROM of adjacent segments increased much more than in the L4-L5 Coflex, ranging from 0.05% to 27.34%.
FIGURE 5

Percentage increment of the range of motion in each segment of samples after single-level L4-L5 Coflex fixation (A) Sample # 1; (B) Sample # 2; (C) Sample # 3; (D) Sample # 4; (E) Sample # 5 and (F) Sample # 6.

Percentage increment of the range of motion in each segment of samples after single-level L4-L5 Coflex fixation (A) Sample # 1; (B) Sample # 2; (C) Sample # 3; (D) Sample # 4; (E) Sample # 5 and (F) Sample # 6. Under all loading conditions, the ROM significantly increased in the L4-L5 Coflex and the L4-L5 Fusion for the upper L3-L4 adjacent segment (p < 0.05), with an increase in the L4-L5 Fusion being much greater than that in the L4-L5 Coflex (p < 0.05), as shown in Figure 6 and Table 3. For the L2-L3 adjacent segments, the ROM in the L4-L5 Coflex and the L4-L5 Fusion increased significantly in flexion, extension, and lateral bending p < 0.05), and there was a significant difference between the two single-level fixation models (p < 0.05). However, for the L1-L2 adjacent segment, both single-level fixations had a significant effect on ROM in flexion and extension, with no significant difference (p > 0.05). Furthermore, neither the L4-L5 Coflex nor the L4-L5 Fusion had a significant effect on the ROM of the inferior L5-S1 adjacent segment.
FIGURE 6

Percentage increment of the range of motion in each segment of samples after single-level L4-L5 Fusion fixation (A) Sample # 1; (B) Sample # 2; (C) Sample # 3; (D) Sample # 4; (E) Sample # 5 and (F) Sample # 6.

TABLE 3

Significant difference in the range of motion of adjacent segments after single-level fusion under different loading.

Normal VS. CoflexNormal VS. FusionCoflex VS. FusionNormal VS. CoflexNormal VS. FusionCoflex VS. Fusion
L3-L4L5-S1
 Extension0.006*0.002*0.017* Extension0.9630.7170.281
 Left-bending0.004*0.007*0.015* Left-bending0.9390.3980.004*
 Right-bending0.001*0.002*0.029* Right-bending0.0510.550.001*
 Left-rotation0.023*0.004*0.058 Left-rotation0.8410.6240.503
 Right-rotation0.015*0.001*0.001* Right-rotation0.9450.170.091
L2-L3L2-L1
 Flexion0.001*0.001*0.008* Flexion0.009*0.003*0.064
 Extension0.004*0.003*0.116 Extension0.014*0.013*0.75
 Left-bending0.019*0.006*0.016* Left-bending0.120.1210.626
 Right-bending0.001*0.001*0.045* Right-bending0.110.0680.034*
 Left-rotation0.3340.3750.754 Left-rotation0.230.0620.833
 Right-rotation0.780.8430.957 Right-rotation0.1620.007*0.204

*Significant difference p < 0.05.

Percentage increment of the range of motion in each segment of samples after single-level L4-L5 Fusion fixation (A) Sample # 1; (B) Sample # 2; (C) Sample # 3; (D) Sample # 4; (E) Sample # 5 and (F) Sample # 6. Significant difference in the range of motion of adjacent segments after single-level fusion under different loading. *Significant difference p < 0.05.

Range of motion in a two-level lumbar fixation model

Under different loading conditions, the overall ROM of L1-S1 segments in the double-level lumbar fixation models (L4-L5 Coflex and L4-L5 Fusion) was shown in Figure 7. Both the Coflex + Fusion and Fusion + Fusion showed no significant influence on the ROM of the inferior L5-S1 adjacent segment (p < 0.05), with the former having less effect in flexion, lateral bending, and axial rotation than the latter (p < 0.05) (Table 4). The ROM differences between the two fixation models were as follows: 1.31°–3.68° in flexion, 0.36°–2.45° in extension, 0.29°–3.93° in lateral bending, and 0.65°–1.99° in axial rotation.
FIGURE 7

Preoperative and postoperative differences in the overall range of motion of each sample. C+F: L4-L5 Coflex + L5-S1 Fusion fixation group; F+F: L4-L5 Fusion + L5-S1 Fusion fixation group.

TABLE 4

Significant difference in the range of motion of two-level fusion under different loading.

Normal VS. Coflex + FusionNormal VS. Fusion + FusionCoflex + Fusion VS. Fusion + Fusion
Flexion0.002*0.001*0.007*
Extension0.001*0.001*0.001*
Left-bending0.004*0.001*0.002*
Right-bending0.015*0.002*0.004*
Left-rotation0.004*0.002*0.009*
Right-rotation0.013*0.006*0.013*

*Significant difference p < 0.05.

Preoperative and postoperative differences in the overall range of motion of each sample. C+F: L4-L5 Coflex + L5-S1 Fusion fixation group; F+F: L4-L5 Fusion + L5-S1 Fusion fixation group. Significant difference in the range of motion of two-level fusion under different loading. *Significant difference p < 0.05.

3.5 Intervertebral rotation distribution in a two-level fixation model

The Coflex dynamic fixation maintained the partial ROM at the L4-L5 level, with a decrease in extension of 40.28%–60.01%, in flexion of 13.09%–26.30%, in lateral bending of 5.48%–20.89%, and in axial rotation of 5.54%–17.59% (Figure 8). In the Coflex + Fusion, the ROM of adjacent segments increased by 4.79%–28.88% in flexion, 1.28%–19.25% in lateral bend, and −3.08% to 12.80% in axial rotation, respectively. In extension, the increase in ROM of adjacent segments was significantly larger than that in other loading conditions, ranging from 9.96% to 30.60%. In the Fusion + Fusion, the ROM of adjacent segments increased by 10.57%–36.17% in flexion, 5.92%–32.40% in extension, 4.78%–29.31% in lateral bend, and −3.12% to 24.70% in axial rotation, respectively. The ROM of adjacent segments in the Fusion + Fusion was significantly larger than that of adjacent segments in the Coflex + Fusion (p < 0.05).
FIGURE 8

Percentage increment of the range of motion in each segment of samples after two-level Coflex + Fusion fixation (A) Sample # 1; (B) Sample # 2; (C) Sample # 3; (D) Sample # 4; (E) Sample # 5 and (F) Sample # 6.

Percentage increment of the range of motion in each segment of samples after two-level Coflex + Fusion fixation (A) Sample # 1; (B) Sample # 2; (C) Sample # 3; (D) Sample # 4; (E) Sample # 5 and (F) Sample # 6. For the upper L3-L4 adjacent segment, the ROM significantly increased in the Coflex + Fusion and the Fusion + Fusion under all loading conditions (p < 0.05), while there was a significant difference only in flexion and lateral bending (p < 0.05), as shown in Figure 9 and Table 5. Similarly, for the L1-L2 and L2-L3 adjacent segments, the double-level fixation had a significant effect on the ROM in flexion, extension and lateral bending, with a significant difference only in flexion and lateral bending (p > 0.05).
FIGURE 9

Percentage increment of the range of motion in each segment of samples after two-level Fusion + Fusion fixation (A) Sample # 1; (B) Sample # 2; (C) Sample # 3; (D) Sample # 4; (E) Sample # 5 and (F) Sample # 6.

TABLE 5

Significant difference in the range of motion of adjacent segments after single-level fusion under different loading.

Normal VS. C+FNormal VS. F+FC+F VS. F+FNormal VS. C+FNormal VS. F+FC+F VS. F+F
L3-L4L2-L3
 Flexion0.001*0.001*0.001* Flexion0.001*0.001*0.017*
 Extension0.001*0.003*0.052 Extension0.002*0.002*0.066
 Left-bending0.005*0.005*0.006* Left-bending0.003*0.003*0.01*
 Right-bending0.001*0.003*0.044* Right-bending0.001*0.002*0.011*
 Left-rotation0.013*0.02*0.32 Left-rotation0.2820.1020.085
 Right-rotation0.003*0.001*0.767 Right-rotation0.0610.0530.611
L2-L1
 Flexion0.002*0.001*0.003* Extension0.007*0.054*0.113
 Left-bending0.005*0.001*0.021* Right-bending0.001*0.001*0.081
 Left-rotation0.0550.8610.389 Right-rotation0.0510.0710.082

*Significant difference p < 0.05; C+F: L4-L5 Coflex + L5-S1 Fusion fixation group; F+F: L4-L5 Fusion + L5-S1 Fusion fixation group.

Percentage increment of the range of motion in each segment of samples after two-level Fusion + Fusion fixation (A) Sample # 1; (B) Sample # 2; (C) Sample # 3; (D) Sample # 4; (E) Sample # 5 and (F) Sample # 6. Significant difference in the range of motion of adjacent segments after single-level fusion under different loading. *Significant difference p < 0.05; C+F: L4-L5 Coflex + L5-S1 Fusion fixation group; F+F: L4-L5 Fusion + L5-S1 Fusion fixation group.

Correlation analysis

The correlation between the original sagittal parameters of the lumbar-pelvis and the ROM in the different fixation models under different loading conditions was shown in Table 6. Only in the L4-L5 Coflex in flexion, the ROM was correlated with four parameters, including PI (r = 0.943), SS (r = 0.943), LL (r = 0.943) and Apex (r = −0.883). In extension, PT had a strong correlation with the ROM both in the single- and double-level fusions. There was no correlation between other sagittal parameters of the normal specimens and the ROM under all loading conditions.
TABLE 6

Correlation between the lumbar-pelvic parameter and the range of motion after fusion under different loading.

FusionLoadingPIPTSSLLApexUpper arcLTANVL
L4-L5 CoflexFlexion 0.943*0.600 0.943* 0.943* −0.883*0.7710.0290.725
Extension0.371 0.886*0.3710.371−0.2940.5430.7140.406
Left-bending0.600−0.0860.6000.600−0.6180.086−0.6570.290
Right-bending0.600−0.0860.6000.600−0.7060.086−0.5430.493
Left-rotation0.143−0.1430.1430.143−0.2650.1430.2570.145
Right-rotation−0.140.143−0.143−0.1430.0880.1430.771−0.087
L4-L5 FusionFlexion−0.0860.543−0.086−0.0860.118−0.0860.600−0.174
Extension0.371 0.886*0.3710.371−0.2940.5430.7140.406
Left-bending0.2000.5430.2000.200−0.2060.7140.7710.638
Right-bending−0.0290.371−0.029−0.0290.0880.6570.7710.319
Left-rotation−0.714−0.143−0.714−0.7140.706−0.5430.429−0.725
Right-rotation0.3710.6000.3710.371−0.1470.6000.1430.203
Coflex + FusionFlexion0.1430.7140.1430.143−0.0880.2570.6000.203
Extension0.771 0.829*0.7710.771−0.736 0.943*0.543 0.899*
Left-bending0.7710.2570.7710.771−0.7940.371−0.1430.435
Right-bending0.543−0.2000.5430.543−0.6180.143−0.6000.435
Left-rotation0.029−0.3710.0290.029−0.0880.029−0.086−0.058
Right-rotation−0.200 −0.829*−0.200−0.2000.088−0.429−0.771−0.145
Fusion + FusionFlexion0.0860.6000.0860.0860.0000.0860.3140.058
Extension0.543 0.943*0.5430.543−0.5000.6000.7710.493
Left-bending0.7140.1430.7140.714−0.7060.200−0.4290.290
Right-bending0.029−0.3710.0290.029−0.0880.029−0.086−0.058
Left-rotation0.174−0.2320.1740.174−0.2390.1450.0000.074
Right-rotation−0.543−0.943*−0.543−0.5430.500−0.600−0.771−0.493

*Significant difference p < 0.05. PI: pelvic incidence; PT, pelvic tilt; SS, sacral slope; LL, lumbar lordosis; Apex, the apex of lordosis; LTA, lumbar title angle; NVL, the number of vertebrae in lordosis.

Correlation between the lumbar-pelvic parameter and the range of motion after fusion under different loading. *Significant difference p < 0.05. PI: pelvic incidence; PT, pelvic tilt; SS, sacral slope; LL, lumbar lordosis; Apex, the apex of lordosis; LTA, lumbar title angle; NVL, the number of vertebrae in lordosis.

Discussion

In this study, we evaluated the kinetic response of the lumbar after different fusion techniques and fixed segments, especially adjacent segments, in combination with in vitro biomechanical testing and spinopelvic radiographic parameters. Both single or double-level spinal fusion had the greatest effect on the ROM of the lumbar under flexion loading, followed by lateral bending, extension and axial rotation loading. The upper adjacent segment was the most influenced by the implant in all fusion models, with the most significant compensatory movement, while the effect diminished as the distance between the adjacent segments increased. The implant, it was thought, altered the geometry of the spine and reconstructed the sagittal parameters match. As a result, neither after single-level lumbar fusion nor after double-level lumbar fusion, most sagittal parameters in the normal spine before fusion correlated with the ROM of the spine. The Coflex dynamic implantation for single-level fixation remained partial movement of the target segment, affecting only the range of movement under extension loading. These findings were consistent with the previous research. Wilke et al. (1998) demonstrated that Coflex dynamic fixation reduced the ROM in the posterior extension of the lumbar spine by approximately 50% compared to the intact lumbar spine, and the ROM was not significantly affected in flexion, lateral bending, and rotation. Pan et al. (2016) also found no significant effects on adjacent segments in the lumbar model after Coflex fixation. The Fusion fixation had a greater effect on the ROM than that of the Coflex fixation, but both limited the extension movement. The ROM of the upper L3-l4 adjacent segment was affected by both fusion methods, however, there was no significant effect on the ROM of the inferior L5-S1 adjacent segment. The result was consistent with the clinical cases, that upper adjacent segments were more prone to secondary accelerated degeneration. For double-segment internal fixation, although Coflex + Fusion fixation had less effect on the motion of adjacent segments than that of Fusion + Fusion fixation, the ROM of adjacent segments also significantly increased. Similar results were reported by Mageswaran et al. (2012) that the ROM of adjacent segments in an in vitro experimental model significantly increased in flexion, extension, and axial rotation after L3-L4 semi-rigid screw dynamic fixation + L4-L5 fusion fixation. Strube et al. (2010) also showed that, after dynamic fixation combined with fusion fixation, the ROM of the upper adjacent segments still increased significantly. It was worth noting that the protection of adjacent segments by this dynamic fixation method may not delay the degeneration of adjacent segments in the case of double-segment fixation. Sagittal alignment plays a critical role in the biomechanical adaptation and compensation of the spine. Our previous study suggested that sagittal parameters were mainly correlated to the ROM response of the lumbar spine under sagittal (flexion and extension) loading, but had little effect on the ROM under lateral flexion and axial rotation loads. In this study, the preoperative lumbar PT was the only sagittal parameter associated with the overall ROM after single or double-level spinal fusions under extension loading. Roussouly and Nnadi (2010), Roussouly and Pinheiro-Franco (2011) advised that PT reflected the ability of the pelvis to rotate around the femoral head. Our results found that most sagittal parameters of the original lumbar before fusion did not correlated with the ROM after both single or double-level lumbar fusion. Traditional internal fixation with stiffness higher than vertebrae completely alters the original structure and shape of the lumbar, putting patients at risk of overtreatment. For the Coflex dynamic fixation, the ROM after fusion was still associated with PI, SS, LL, and Apex in flexion. That indicated that Coflex dynamic fixation had less interference with the original morphology of the lumbar spine, but, in the Coflex + Fusion fixation, such retention of the original morphology disappeared. There were several limitations to the current study. Firstly, the number of samples in this study was limited due to the difficulty in obtaining qualified lumbar spine specimens. These data did not support a correlation analysis between the lumbar sagittal classification of lumbar vertebrae and ROM. Secondly, in vitro testing protocols and facilities for similar studies are complex and diverse. Our data cannot be directly compared with published results from other experiments. Thirdly, muscles and other soft tissues of the spine were not considered in this biomechanical testing. The results are somewhat different from the real state of the human lumbar spine. Despite these limitations, our study can provide insights into how single or double-level spinal fusion affects lumbar motion and a better understanding of the correlation between preoperative sagittal parameters and lumbar movements after different lumbar internal fixation techniques.

Conclusion

Our findings revealed the different kinetic characteristics of the dynamic Coflex and rigid fusion devices for single and double-level lumbar fusion. The Coflex exhibited its advantage in single-level lumbar fusion that preserved partial movement of the target segment and lowered motion compensation in the upper adjacent segment. For the double-level lumbar fixation, although the range of motion of adjacent segments in the Coflex + Fusion fixation was smaller than that in the Fusion + Fusion fixation, there was no significant difference. PT was the only preoperative lumbar sagittal parameter associated with the range of motion after single and double-level fusions in extension. Coflex dynamic fixation showed the ability to reduce interference in the lumbar spine’s original shape. This study proposed a preliminary experimental assessment approach for studying the effects of various surgical implants on the biomechanical response of patients with a range of preoperative lumbar sagittal parameters.
  28 in total

1.  Optimal Reconstruction of Sagittal Alignment According to Global Alignment And Proportion Score Can Reduce Adjacent Segment Degeneration After Lumbar Fusion.

Authors:  Muyi Wang; Liang Xu; Xi Chen; Qingshuang Zhou; Changzhi Du; Bo Yang; Zezhang Zhu; Bin Wang; Yong Qiu; Xu Sun
Journal:  Spine (Phila Pa 1976)       Date:  2021-02-15       Impact factor: 3.468

2.  Hybrid dynamic stabilization: a biomechanical assessment of adjacent and supraadjacent levels of the lumbar spine.

Authors:  Prasath Mageswaran; Fernando Techy; Robb W Colbrunn; Tara F Bonner; Robert F McLain
Journal:  J Neurosurg Spine       Date:  2012-07-27

3.  Description of the sagittal alignment of the degenerative human spine.

Authors:  Amer Sebaaly; Pierre Grobost; Lisa Mallam; Pierre Roussouly
Journal:  Eur Spine J       Date:  2017-11-24       Impact factor: 3.134

Review 4.  Biomechanical analysis of the spino-pelvic organization and adaptation in pathology.

Authors:  Pierre Roussouly; João Luiz Pinheiro-Franco
Journal:  Eur Spine J       Date:  2011-08-02       Impact factor: 3.134

Review 5.  Adjacent segment degeneration after lumbar spinal fusion compared with motion-preservation procedures: a meta-analysis.

Authors:  Aixing Pan; Yong Hai; Jincai Yang; Lijin Zhou; Xiaolong Chen; Hui Guo
Journal:  Eur Spine J       Date:  2016-03-11       Impact factor: 3.134

6.  Classification of the normal variation in the sagittal alignment of the human lumbar spine and pelvis in the standing position.

Authors:  Pierre Roussouly; Sohrab Gollogly; Eric Berthonnaud; Johanes Dimnet
Journal:  Spine (Phila Pa 1976)       Date:  2005-02-01       Impact factor: 3.468

7.  Operative treatment of the degenerated segment adjacent to a lumbar fusion.

Authors:  T S Whitecloud; J M Davis; P M Olive
Journal:  Spine (Phila Pa 1976)       Date:  1994-03-01       Impact factor: 3.468

8.  Paraspinal muscle, facet joint, and disc problems: risk factors for adjacent segment degeneration after lumbar fusion.

Authors:  Jong Yeol Kim; Dal Sung Ryu; Ho Kyu Paik; Sang Soak Ahn; Moo Sung Kang; Kyung Hyun Kim; Jeong Yoon Park; Dong Kyu Chin; Keun Su Kim; Yong Eun Cho; Sung Uk Kuh
Journal:  Spine J       Date:  2016-03-09       Impact factor: 4.166

Review 9.  Cervical spine models for biomechanical research.

Authors:  M M Panjabi
Journal:  Spine (Phila Pa 1976)       Date:  1998-12-15       Impact factor: 3.468

10.  A Barycentremetric study of the sagittal shape of spine and pelvis: the conditions required for an economic standing position.

Authors:  G Duval-Beaupère; C Schmidt; P Cosson
Journal:  Ann Biomed Eng       Date:  1992       Impact factor: 3.934

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.