Literature DB >> 36061217

An Iterative Least Squares Method for Proton CT Image Reconstruction.

Don F DeJongh1, Ethan A DeJongh1.   

Abstract

Clinically useful proton Computed Tomography images will rely on algorithms to find the three-dimensional proton stopping power distribution that optimally fits the measured proton data. We present a least squares iterative method with many features to put proton imaging into a more quantitative framework. These include the definition of a unique solution that optimally fits the protons, the definition of an iteration vector that takes into account proton measurement uncertainties, the definition of an optimal step size for each iteration individually, the ability to simultaneously optimize the step sizes of many iterations, the ability to divide the proton data into arbitrary numbers of blocks for parallel processing and use of graphical processing units, and the definition of stopping criteria to determine when to stop iterating. We find that it is possible, for any object being imaged, to provide assurance that the image is quantifiably close to an optimal solution, and the optimization of step sizes reduces the total number of iterations required for convergence. We demonstrate the use of these algorithms on real data.

Entities:  

Keywords:  iterative algorithm; least squares; parallel processing; proton computed tomography; proton imaging; relaxation coefficient; stopping criterion

Year:  2021        PMID: 36061217      PMCID: PMC9432481          DOI: 10.1109/trpms.2021.3079140

Source DB:  PubMed          Journal:  IEEE Trans Radiat Plasma Med Sci        ISSN: 2469-7303


  14 in total

1.  Density resolution of proton computed tomography.

Authors:  Reinhard W Schulte; Vladimir Bashkirov; Márgio C Loss Klock; Tianfang Li; Andrew J Wroe; Ivan Evseev; David C Williams; Todd Satogata
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

2.  Filtered backprojection proton CT reconstruction along most likely paths.

Authors:  Simon Rit; George Dedes; Nicolas Freud; David Sarrut; Jean Michel Létang
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

3.  Fast reconstruction of low dose proton CT by sinogram interpolation.

Authors:  David C Hansen; Thomas Sangild Sørensen; Simon Rit
Journal:  Phys Med Biol       Date:  2016-07-22       Impact factor: 3.609

Review 4.  Myths and realities of range uncertainty.

Authors:  Antony John Lomax
Journal:  Br J Radiol       Date:  2019-12-23       Impact factor: 3.039

5.  An Improved Method of Total Variation Superiorization Applied to Reconstruction in Proton Computed Tomography.

Authors:  Blake Schultze; Yair Censor; Paniz Karbasi; Keith E Schubert; Reinhard W Schulte
Journal:  IEEE Trans Med Imaging       Date:  2019-04-16       Impact factor: 10.048

6.  A comparison of proton stopping power measured with proton CT and x-ray CT in fresh postmortem porcine structures.

Authors:  Don F DeJongh; Ethan A DeJongh; Victor Rykalin; Greg DeFillippo; Mark Pankuch; Andrew W Best; George Coutrakon; Kirk L Duffin; Nicholas T Karonis; Caesar E Ordoñez; Christina Sarosiek; Reinhard W Schulte; John R Winans; Alec M Block; Courtney L Hentz; James S Welsh
Journal:  Med Phys       Date:  2021-11-18       Impact factor: 4.071

Review 7.  Review of medical radiography and tomography with proton beams.

Authors:  Robert P Johnson
Journal:  Rep Prog Phys       Date:  2018-01

8.  Analysis of characteristics of images acquired with a prototype clinical proton radiography system.

Authors:  Christina Sarosiek; Ethan A DeJongh; George Coutrakon; Don F DeJongh; Kirk L Duffin; Nicholas T Karonis; Caesar E Ordoñez; Mark Pankuch; Victor Rykalin; John R Winans; James S Welsh
Journal:  Med Phys       Date:  2021-03-22       Impact factor: 4.071

9.  Software platform for simulation of a prototype proton CT scanner.

Authors:  Valentina Giacometti; Vladimir A Bashkirov; Pierluigi Piersimoni; Susanna Guatelli; Tia E Plautz; Hartmut F-W Sadrozinski; Robert P Johnson; Andriy Zatserklyaniy; Thomas Tessonnier; Katia Parodi; Anatoly B Rosenfeld; Reinhard W Schulte
Journal:  Med Phys       Date:  2017-03       Impact factor: 4.506

View more