Identifying Calcaneal Anatomical Regions of Interest (ROI) for Quantitative Ultrasound Application in Subadults.

Connor S Blythe1, Mikaela S Reynolds2, Laura S Gregory2.   

Abstract

Whilst quantitative ultrasound can be reliably used to assess bone health in adults, the fixed location of the transducers in current devices may result in inaccurate and unreliable measurements in bone assessment in children due to the variation in foot size during growth. To improve positioning for paediatric assessment, Jaworski et al. (1995) created an anatomical method to identify the region of interest (ROI), however, there have been no medical imaging studies to confirm that the Jaworski method results in consistent placement of the transducer on the centre of the calcaneal body to avoid edge artefacts. In this study, computed tomography scans of the tarsus were collected from 498 individuals (258 females; 240 males) aged 2 to 20 years and used to create three novel anatomical methods to identify ROI on the calcaneus using palpable landmarks. In addition, the established Jaworski method was applied to the same scans and compared to our novel methods. The maximum ROI significantly increased with age with males having significantly greater diameters, supporting the recommendation that ½ inch diameter transducers should be used on individuals younger than 7 years of age. We identified that 79% of the 'Jaworski points' lied anterosuperior to the ROI centre point identified in this study, with 10% of the points lying outside the ROI. Of the three novel methods, only the calcaneal insertion method demonstrated small measurement variance between individuals of the same age in each sex and is therefore the preferred method for ultrasound clinical application.
© 2022. The Author(s).

Entities:  

Keywords:  Calcaneus; Computed tomography; Pediatric development; Quantitative ultrasound; Region of interest

Year:  2022        PMID: 36044069     DOI: 10.1007/s00223-022-01018-3

Source DB:  PubMed          Journal:  Calcif Tissue Int        ISSN: 0171-967X            Impact factor:   4.000


  20 in total

1.  Dual-photon absorptiometry for determination of bone mineral content in the calcaneus with correction for fat.

Authors:  R Jonson; L G Månsson; A Rundgren; J Szücs
Journal:  Phys Med Biol       Date:  1990-07       Impact factor: 3.609

2.  Ultrasound and dual X-ray absorptiometry measurement of the calcaneus: influence of region of interest location.

Authors:  K Brooke-Wavell; P R Jones; D W Pye
Journal:  Calcif Tissue Int       Date:  1995-07       Impact factor: 4.333

3.  Preliminary evaluation of a new ultrasound bone densitometer.

Authors:  B Lees; J C Stevenson
Journal:  Calcif Tissue Int       Date:  1993-09       Impact factor: 4.333

4.  Normative calcaneal quantitative ultrasound data as an estimation of skeletal development in Swedish children and adolescents.

Authors:  Gayani Alwis; Björn Rosengren; Jan Ake Nilsson; Susanna Stenevi-Lundgren; Martin Sundberg; Ingemar Sernbo; Magnus K Karlsson
Journal:  Calcif Tissue Int       Date:  2010-10-20       Impact factor: 4.333

5.  Topographical distribution of trabecular bone strength in the human os calcanei.

Authors:  N C Jensen; L P Madsen; F Linde
Journal:  J Biomech       Date:  1991       Impact factor: 2.712

6.  Bone densitometry in Canadian children 8-17 years of Age.

Authors:  R A Faulkner; D A Bailey; D T Drinkwater; H A McKay; C Arnold; A A Wilkinson
Journal:  Calcif Tissue Int       Date:  1996-11       Impact factor: 4.333

7.  Quantitative ultrasound assessment in children with fractures.

Authors:  Johannes Schalamon; Georg Singer; Gerold Schwantzer; Yrjänä Nietosvaara
Journal:  J Bone Miner Res       Date:  2004-04-05       Impact factor: 6.741

8.  Effect of region of interest location on ultrasound measurements of the calcaneus.

Authors:  J Damilakis; K Perisinakis; E Vagios; D Tsinikas; N Gourtsoyiannis
Journal:  Calcif Tissue Int       Date:  1998-10       Impact factor: 4.333

9.  Ultrasound bone measurement in pediatric subjects.

Authors:  M Jaworski; M Lebiedowski; R S Lorenc; J Trempe
Journal:  Calcif Tissue Int       Date:  1995-05       Impact factor: 4.333

10.  Calcaneus ultrasound measurements in a convenience sample of healthy youth.

Authors:  A Sawyer; S Moore; K T Fielding; D A Nix; J Kiratli; L K Bachrach
Journal:  J Clin Densitom       Date:  2001       Impact factor: 2.963

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.