Literature DB >> 36008733

Comparison of image quality and depiction of microscopic fat at 2-D and 3-D T1-Weighted (T1W) chemical shift (dual-echo) MRI for evaluation of adrenal adenomas.

Hana Alfaleh1, Gerd Melkus2, Khalid Alo Nasiyabi1, Matthew D F McInnes1, Nicola Schieda3.   

Abstract

OBJECTIVE: To compare image quality and detection of microscopic fat in adrenal adenomas imaged with 2-D and 3-D chemical shift imaging (CSI) and, to derive parameters which best match 2-D and 3-D-CSI.
METHODS: This two-phase, retrospective, and phantom + prospective study was IRB approved. First, a retrospective assessment of 50 consecutive adrenal adenomas imaged at 1.5 T with 2-D (TR minimum, Flip Angle [FA] 70°, TE 2.2/4.4 ms.) and 3-D (TR minimum, FA 10°, TE 2.2/4.4 ms.] CSI was performed. Second, phantom (varied fat: water concentration) experiments guided a prospective assessment of 12 consecutive adrenal adenomas imaged at 1.5 T with 3-D CSI (FA 10°, 18°). Two blinded radiologists independently evaluated: image quality, signal intensity (SI) cancellation (5-point Likert scale), and CSI-index ([SI.In.Phase-SI.Opposed.Phase/SI.In.Phase]*100).
RESULTS: 2-D-CSI yielded higher image quality (p < 0.001) and, subjectively (p < 0.001) and quantitatively (p < 0.001) had more SI cancellation from microscopic fat. Proportion of adenomas with no detectable microscopic fat (3-D; 26-36% subjectively, 18-24% quantitatively [CSI-index < 16.5%] versus 2-D; 20-22% subjectively, 6-8% quantitatively) differed (p = 0.008-0.08 subjectively, 0.008-0.03 quantitatively) by CSI technique. Phantom experiments indicated 18°FA 3-D-CSI compared favorably to 70° 2-D-CSI for fat detection between 5% and 50%. In vivo, there was no differences in subjective or quantitative SI cancellation comparing 18°3D-CSI and 2D-CSI (p = 0.16-0.56 and 0.73-0.60). Greater SI cancellation occurred with 18°3D compared to 10°3D-CSI evaluated subjectively (p = 0.003-0.01).
CONCLUSION: 2-D CSI has subjectively higher image quality and shows more signal intensity loss from microscopic fat in adrenal adenomas compared to 10° flip angle 3-D-CSI. Increasing the 3-D flip angle to 18° more closely matches depiction of microscopic fat to 2-D-CSI at 1.5 T.
© 2022. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.

Entities:  

Keywords:  Adenoma; Adrenal; Chemical Shift; Fat; MRI

Mesh:

Substances:

Year:  2022        PMID: 36008733     DOI: 10.1007/s00261-022-03648-5

Source DB:  PubMed          Journal:  Abdom Radiol (NY)


  3 in total

Review 1.  Multiparametric MRI of solid renal masses: pearls and pitfalls.

Authors:  N K Ramamurthy; B Moosavi; M D F McInnes; T A Flood; N Schieda
Journal:  Clin Radiol       Date:  2014-12-01       Impact factor: 2.350

2.  Prevalence of Malignancy in Adrenal Nodules With Heterogeneous Microscopic Fat on Chemical-Shift MRI: A Multiinstitutional Study.

Authors:  Myles T Taffel; Robert D Petrocelli; Danielle Rigau; Nicola Schieda; Sumaya Al-Rasheed; Benjamin W Carney; Ryan Chung; Michael L Yao; Michael A Blake; Khaled M Elsayes; Mohamed Badawy; Sergio Klimkowski; Erick M Remer; Adam Wetzel; Amit Pandya; Elaine M Caoili; Michael T Corwin
Journal:  AJR Am J Roentgenol       Date:  2022-10-19       Impact factor: 6.582

3.  Fat-Water Phantoms for Magnetic Resonance Imaging Validation: A Flexible and Scalable Protocol.

Authors:  Emily C Bush; Aliya Gifford; Crystal L Coolbaugh; Theodore F Towse; Bruce M Damon; E Brian Welch