Commentary: Without missing a beat-Is preserving pulsatility the most important feature of the advanced ventricular assist device?

David D Yuh1.   

Abstract

Entities:  

Year:  2020        PMID: 36003860      PMCID: PMC9390600          DOI: 10.1016/j.xjon.2020.07.003

Source DB:  PubMed          Journal:  JTCVS Open        ISSN: 2666-2736


× No keyword cloud information.
David D. Yuh, MD, FACS, FACC The novel sliding rotor mechanism of the advanced ventricular assist device prototype shows promise in addressing several perennial limitations of current long-term circulatory assist devices. See Article page 140. The advanced ventricular assist device (VAD) prototype Miyamoto and colleagues have developed addresses several important limitations with current VAD technologies, relevant to the broader clinical applications of long-term mechanical circulatory support. Of central interest is the novel sliding rotor mechanism of the advanced VAD that preserves arterial pulsatility with direct beat-to-beat dynamic coupling of pump flow with the native ventricles, optimizing diastolic preload and systolic afterload. Certainly, inducing pulsatility has been accomplished in other continuous-flow left ventricular assist devices through rotational speed modulation of the pump impeller; however, this appears to be a less “physiologic” modality that would not appear to be as sensitive to dynamic changes in pre- and afterload conditions. That said, the clinical importance of maintaining arterial pulsatility remains uncertain and controversial. There is no lack of published evidence supporting the deleterious long-term physiologic consequences of diminished or absent pulsatility and greater shear-stress forces upon the peripheral microcirculation,, including thrombogenesis (eg, diminished circulating von Willebrand factor), endothelial nitric oxide bioavailability, and end-organ function. However, clinically significant consequences of these largely theoretical manifestations have not been consistently observed in patients with end-stage heart failure supported by continuous-flow devices and certainly do not outweigh the markedly improved quality of life and prognoses conferred by these devices, including their pulsatile predecessors. The intrinsic shut-off feature of the advanced VAD preventing regurgitant flow during pump stoppage is a valuable weaning feature of the sliding rotor mechanism, particularly since several centers have successfully weaned and explanted continuous-flow VADs in small-but-significant numbers of patients using different strategies to predict success., The ability to temporarily subtract VAD circulatory support may prompt more aggressive VAD-weaning trials. It is worth noting that cessation of pump flow for appreciable amounts of time during such weaning trials with this device may require special anticoagulation considerations, given the heightened risk of pump thrombosis. Regarding device durability, adding the sliding mechanism to the rotational action of the impeller might introduce an additional point of mechanical failure or vulnerability to thrombosis. For example, could fibrin deposition interfere with the sliding surfaces of the rotor within the pump housing, potentially leading to a fixed low-flow state? Right ventricular failure following VAD implantation continues to be a vexing problem that is associated with significant perioperative mortality and morbidity. Although temporary right ventricular assist device (RVAD) support has been successfully used in instances of unexpected right ventricular failure, a significant number of these patients have failed weaning in several series and delayed RVAD implantation has been associated with high mortality rates. As a dedicated long-term RVAD has yet to be developed, the wider performance range of the advanced universal VAD presents a device more well suited to accommodate the lower-flow requirements and greater thrombosis risk of right-sided support. Miyamoto and colleagues are to be congratulated for this in vivo “proof of concept” report of a novel adaptive advanced VAD mechanism that seeks to address some of the most persistent and challenging issues in long-term circulatory support.
  6 in total

1.  Further Peripheral Vascular Dysfunction in Heart Failure Patients With a Continuous-Flow Left Ventricular Assist Device: The Role of Pulsatility.

Authors:  Melissa A H Witman; Ryan S Garten; Jayson R Gifford; H Jonathan Groot; Joel D Trinity; Josef Stehlik; Jose N Nativi; Craig H Selzman; Stavros G Drakos; Russell S Richardson
Journal:  JACC Heart Fail       Date:  2015-08-12       Impact factor: 12.035

2.  Outcomes from a recovery protocol for patients with continuous-flow left ventricular assist devices.

Authors:  Jan Knierim; Roland Heck; Marina Pieri; Felix Schoenrath; Sajjad Soltani; Philipp Stawowy; Stephan Dreysse; Julia Stein; Marcus Müller; Johanna Mulzer; Michael Dandel; Volkmar Falk; Thomas Krabatsch; Evgenij Potapov
Journal:  J Heart Lung Transplant       Date:  2018-11-15       Impact factor: 10.247

3.  Rotational speed modulation used with continuous-flow left ventricular assist device provides good pulsatility.

Authors:  Noritsugu Naito; Takashi Nishimura; Kei Iizuka; Yoshiaki Takewa; Akihide Umeki; Masahiko Ando; Minoru Ono; Eisuke Tatsumi
Journal:  Interact Cardiovasc Thorac Surg       Date:  2018-01-01

4.  Ventricular reconditioning and pump explantation in patients supported by continuous-flow left ventricular assist devices.

Authors:  O H Frazier; Andrew C W Baldwin; Zumrut T Demirozu; Ana Maria Segura; Ruben Hernandez; Heinrich Taegtmeyer; Hari Mallidi; William E Cohn
Journal:  J Heart Lung Transplant       Date:  2014-09-28       Impact factor: 10.247

5.  Outcome of unplanned right ventricular assist device support for severe right heart failure after implantable left ventricular assist device insertion.

Authors:  Koji Takeda; Yoshifumi Naka; Jonathan A Yang; Nir Uriel; Paolo C Colombo; Ulrich P Jorde; Hiroo Takayama
Journal:  J Heart Lung Transplant       Date:  2013-08-06       Impact factor: 10.247

6.  Arterial Pulsatility and Circulating von Willebrand Factor in Patients on Mechanical Circulatory Support.

Authors:  Flavien Vincent; Antoine Rauch; Valentin Loobuyck; Emmanuel Robin; Christoph Nix; André Vincentelli; David M Smadja; Pascal Leprince; Julien Amour; Gilles Lemesle; Hugues Spillemaeker; Nicolas Debry; Christian Latremouille; Piet Jansen; Antoine Capel; Mouhamed Moussa; Natacha Rousse; Guillaume Schurtz; Cédric Delhaye; Camille Paris; Emmanuelle Jeanpierre; Annabelle Dupont; Delphine Corseaux; Mickaël Rosa; Yoann Sottejeau; Svenja Barth; Claudia Mourran; Valérie Gomane; Augustin Coisne; Marjorie Richardson; Claudine Caron; Cristian Preda; Alexandre Ung; Alain Carpentier; Thomas Hubert; Cécile Denis; Bart Staels; Peter J Lenting; Eric Van Belle; Sophie Susen
Journal:  J Am Coll Cardiol       Date:  2018-05-15       Impact factor: 24.094

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.