| Literature DB >> 35992049 |
Abstract
The introduction of SARS-CoV-2 into water bodies via sewage raises public health concerns. For the assessment of public health risks, it is necessary to know the presence and persistence of infectious SARS-CoV-2 in water and wastewater. The present mini-review documents the occurrence and decay rates of viable infectious SARS-CoV-2 and SARS-CoV-2 RNA in different water matrices including wastewater, river water, groundwater, tap water, and seawater. Persistence of viable SARS-CoV-2 is mainly temperature dependent. A rapid inactivation of infectious SARS-CoV-2 is found in river water, sea water, and wastewater compared to tap water. SARS-CoV-2 RNA was found to be considerably more stable than infectious SARS-CoV-2, indicating that the environmental detection of RNA alone does not prove risk of infection. Persistence assays need to consider physicochemical and biological water composition as well as the effect of detergents, enzymes, and filtering particulate matter.Entities:
Keywords: Decay rate; SARS-CoV-2; Stability; Wastewater; Water
Year: 2022 PMID: 35992049 PMCID: PMC9382236 DOI: 10.1016/j.coesh.2022.100385
Source DB: PubMed Journal: Curr Opin Environ Sci Health ISSN: 2468-5844
Figure 1Boxplots of detection of SARS-CoV-2 in different compartment of wastewater treatment facilities, river water and groundwater from data previously reported in the literature (modified and updated from the study by Yang et al. [13]).
Best fitting models and T90 estimates using SARS-CoV-2 and SARS-CoV-2 RNA in different water matrices
| Article | Virus | Matrix | Temperature (°C) | Best fit model | R2 of | RMSE | T90 (days) | Data location in the mentioned article | |
|---|---|---|---|---|---|---|---|---|---|
| [ | SARS-CoV-2 RNA | Raw wastewater | 4 | First order | −0.13 | 0.74 | – | 17.17 | Table 2 |
| Raw wastewater | 26 | First order | −0.27 | 0.99 | – | 7.68 | Table 2 | ||
| [ | SARS-CoV-2 | River water (filter sterilized) | 4 | First order | 0.61 | 0.93 | 0.57 | 3.8 | Table 2 |
| River water (filter sterilized) | 20 | First order | 1.01 | 0.92 | 0.66 | 2.3 | Table 2 | ||
| Seawater (filter sterilized) | 4 | First order | 1.07 | 0.91 | 0.73 | 2.2 | Table 2 | ||
| Seawater (filter sterilized) | 20 | First order | 2.02 | 0.99 | 0.28 | 1.1 | Table 2 | ||
| SARS-CoV-2 RNA | Seawater (filter sterilized) | 20 | First order | 0.14 | 0.80 | 0.3 | 16.6 | Tables 4 and 5 | |
| Seawater (non-filter sterilized) | 20 | First order | 0.26 | 0.46 | 1.08 | 8.9 | Tables 4 and 5 | ||
| [ | SARS-CoV-2 | River water | 24 | First order/Weibull | −0.37 | 0.65 | 0.049 | 1.9 | Table 4 |
| River water | 4 | First order/Weibull | −0.16 | 0.76 | 0.064 | 7.7 | Table 4 | ||
| River water (filtered) | 24 | First order/Weibull | −0.32 | 0.82 | 0.067 | 3.3 | Table 4 | ||
| Wastewater | 24 | First order/Weibull | −0.83 | 0.79 | 0.022 | 1.2 | Table 4 | ||
| Wastewater | 4 | First order/Weibull | −0.19 | 0.75 | 0.062 | 5.5 | Table 4 | ||
| Wastewater (filtered) | 24 | First order/Weibull | −0.80 | 0.80 | 0.052 | 1.5 | Table 4 | ||
| [ | SARS-CoV-2 RNA | Raw wastewater | 37 | First order | 0.29 | 0.74 | 1.10 | 8.04 | Table 3 |
| Raw wastewater | 25 | First order | 0.18 | 0.87 | 0.67 | 12.6 | Table 3 | ||
| Raw wastewater | 15 | First order | 0.11 | 0.71 | 0.59 | 20.4 | Table 3 | ||
| Raw wastewater | 4 | First order | 0.08 | 0.79 | 0.37 | 27.8 | Table 3 | ||
| Autoclaved wastewater | 37 | First order | 0.41 | 0.94 | 0.59 | 5.71 | Table 3 | ||
| Autoclaved wastewater | 25 | First order | 0.17 | 0.93 | 0.48 | 13.5 | Table 3 | ||
| Autoclaved wastewater | 15 | First order | 0.08 | 0.85 | 0.32 | 29.9 | Table 3 | ||
| Autoclaved wastewater | 4 | First order | 0.05 | 0.95 | 0.14 | 43.2 | Table 3 | ||
| Tap water | 37 | First order | 0.04 | 0.88 | 0.86 | 9.4 | Table 3 | ||
| Tap water | 25 | First order | 0.05 | 0.78 | 0.68 | 15.2 | Table 3 | ||
| Tap water | 15 | First order | 0.15 | 0.28 | 0.33 | 51.2 | Table 3 | ||
| Tap water | 4 | First order | 0.25 | 0.83 | 0.17 | 58.6 | Table 3 | ||
| [ | SARS-CoV-2 | Wastewater (low titer) | 20 | First order | 1.4 | 0.71 | 1.8 | 1.6 | Table 1 |
| Wastewater (high titer) | 20 | First order | 1.1 | 0.54 | 1.2 | 2.1 | Table 1 | ||
| Tap water (high titer) | 20 | First order | 1.2 | 0.88 | 1.2 | 1.7 | Table 1 | ||
| Wastewater | 50 | First order | 0.15 min−1 | 0.68 | 1.4 | 15 min | Table 1 | ||
| Wastewater | 70 | First order | 1.0 min−1 | 0.88 | 1.9 | 2.2 min | Table 1 |