| Literature DB >> 35991791 |
Niveditha Bhupanapadu1, Mohammed A Sattar1, Arpita Deb2.
Abstract
Aim: To evaluate nanoleakage depth and pattern of cervical restorations bonded with different adhesive systems. Materials and methods: Thirty-six extracted human premolar teeth were used for the study and grouped according to different bonding agents.Group I: fifth generation dentin bonding agent-ONE COAT SL.Group II: sixth generation dentin bonding agent-PARABOND.Group III: seventh generation dentin bonding agent-ONE COAT 7.0.For nanoleakage depth evaluation, 36 teeth were divided into three groups of 12 teeth each, according to adhesive systems used. For each adhesive system, teeth were subdivided into three subgroups of four teeth each, according to storage period, 24 hours, 1 month, and 3 months before the examination. In each tooth, two cavities were prepared (buccal and lingual), each cavity was lined with different adhesive systems and restored using a nanohybrid composite. The restored teeth were then immersed in water bath at temperature 37oC for intended period of time and then stored in 50% silver nitrate for 24 hours and photo developing solution for 8 hours. After this, the teeth were cut in buccolingual direction and subjected to scanning electron microscope (SEM) analysis for nanoleakage depth analysis.Entities:
Keywords: Dentinbonding; Hybrid layer; Nanoleakage
Year: 2022 PMID: 35991791 PMCID: PMC9357532 DOI: 10.5005/jp-journals-10005-2391
Source DB: PubMed Journal: Int J Clin Pediatr Dent ISSN: 0974-7052
Fig. 1Armamentarium
Fig. 2Prepared cavity on buccal aspect
Fig. 3Restored buccal cavity
Fig. 4Sectioning of tooth
Mean and standard deviation of groups I, II, and III at 24 hours, 1 month, and 3 months
|
|
|
|
| ||||
|---|---|---|---|---|---|---|---|
|
|
|
|
|
|
| ||
| 24 hours | 0.2506 | 0. 02323 | 0.6106 | 0. 02863 | 0.2869 | 0. 01740 | 0.000 |
| 1 month | 0.4069 | 0. 04771 | 0.9113 | 0. 03096 | 0.3838 | 0.0161 | 0.000 |
| 3 months | 0.7313 | 0. 05427 | 0.9113 | 0. 03096 | 0.5544 | 0. 01788 | 0.000 |
Fig. 5After 24 hours group II shows maximum leakage, followed by group III and group I
Fig. 6After 1 month, group II shows maximum leakage, not much difference in mean of group I and group III
Fig. 7After 3 months, group III showed least leakage. Group II showed highest, followed by group I
Fig. 8SEM image of sample stored for 24 hours showing “circular dot” pattern
Fig. 9SEM image of sample stored for 3 months showing reticular pattern