Simple completion Bentall procedure of preserving aortic bioprosthesis after aortic valve replacement.

Soichiro Henmi1,2, Raffaele Scaffa1, Giulio Folino1,3, Ruggero De Paulis1.   

Abstract

Entities:  

Year:  2022        PMID: 35967236      PMCID: PMC9366610          DOI: 10.1016/j.xjtc.2022.04.020

Source DB:  PubMed          Journal:  JTCVS Tech        ISSN: 2666-2507


× No keyword cloud information.
Simple and feasible completion Bentall procedure preserving aortic bioprosthesis. Bioprosthesis-preserving aortic root replacement is an extremely rare situation. The size of the Valsalva graft should be decided after measuring the “true” external sewing ring diameter. The “completion Bentall” is a redo procedure that consists in replacing the aortic root with reimplantation of coronary ostia in the case of a previously implanted normally functioning aortic prosthesis. Bioprosthesis-preserving completion Bentall operation in particular is an extremely rare situation.2, 3, 4, 5 We describe a simple and feasible technique of completion Bentall procedure preserving aortic bioprosthesis after aortic valve replacement.

Clinical Scenario

In this specific situation, after 4 years from an implantation of a 21-mm Carpentier-Edwards Magna pericardial prosthesis (Edwards Lifesciences), we were faced with a 60-mm aortic root aneurysm due to chronic aortic dissection. At the time of initial surgery, the aortic root and the ascending aorta were macroscopically unremarkable. There were no signs of paravalvular leakage or structural valve deterioration in the preoperative transesophageal echocardiogram.

Surgical Technique

Completion Bentall procedure preserving the previously implanted aortic bioprosthesis was performed as shown in Video 1. The aortic arch and the right atrium were canulated to initiate cardiopulmonary bypass. Following the clamping of the aorta, myocardial protection was achieved by blood cardioplegia in the aortic root. After cardiac arrest, the aneurysmal aortic wall was completely removed. A limited entry tear was found just above the orifice of the left coronary artery. Visual aspect revealed an intact bioprosthesis without leaflet calcifications, tears, infection, or thrombus (Figure 1, A). Each coronary ostium was detached. The external sewing ring diameter of the implanted 21-mm Carpentier-Edwards Magna pericardial prosthesis was exactly 28 mm measured with the unlabeled cylindric sizer (Figure 1, B). Eleven interrupted single sutures of 2-0 CV-25 braided polyester (Covidien) were placed on the outer edge of the bioprosthesis sewing ring (Figures 1, A, and 2). The aortic root was replaced using a 28-mm Valsalva graft (Terumo Aortic, Vascutek Ltd). The collar at the bottom of the graft was trimmed to a length of 4 mm (approximately 4 crimps) and connected to the prosthesis sewing ring. Each coronary ostia were reattached to the graft by using the button technique. After distal graft anastomosis, the aortic clamping was removed. There was no bleeding at the proximal anastomosis. Aortic crossclamp time was 78 minutes and cardiopulmonary bypass time was 86 minutes. Blood transfusion was not necessary. The postoperative course was uneventful without complications.
Figure 1

Intraoperative picture. A, Eleven interrupted single sutures were placed on the lateral area in the sewing ring. B, Measuring the “true” external sewing ring diameter by the 28-mm sizer.

Figure 2

The operative techniques in the simple completion Bentall procedure of preserving bioprosthesis.

Intraoperative picture. A, Eleven interrupted single sutures were placed on the lateral area in the sewing ring. B, Measuring the “true” external sewing ring diameter by the 28-mm sizer. The operative techniques in the simple completion Bentall procedure of preserving bioprosthesis.

Discussion

Whether to remove or preserve the bioprosthesis is still matter of controversy. Removal and reimplantation of the new bioprosthesis might offer extended durability; however, it also necessitates prolonged operative time and reimplantation into a damaged aortic annulus, which can cause further complications such as bleeding. Urbanski and colleagues reported that removing a previously implanted aortic prosthesis led to considerable damage of annular tissue with an increase of mortality up to 12%. In addition, in the present case the bioprosthesis was implanted only 4 years ago and was considered in very good condition. Therefore, it was preserved. In this procedure, although it is theoretically possible to suture the graft to a rim of aortic tissue above the annulus, this approach will expose the patient to additional risk, like tissue tearing with bleeding or pseudoaneurysm formation or flow stagnation between the sewing ring and the Valsalva graft. By securing the graft to the prosthesis's sewing ring, we reproduce the standard situation of a Bentall procedure, minimizing complications. We believe that optimized size selection for the Dacron graft plays a key role in this approach. A wrong graft size may lead to complications such as uncontrollable bleeding and future occurrence of pseudoaneurysm. Generally, in the primary Bentall procedure, biological conduits are customized by selecting a Valsalva graft 3-5 mm larger than the aortic prosthesis size. In the described case, the “true” external sewing ring diameter of the 21-mm bioprosthesis, measured using an unlabeled cylindric sizer, was 28 mm (2 mm larger than the reported size). This can be speculated to be due to the enlargement of the prosthesis sewing ring by the compressing sutures of the initial operation. Thus, a direct and precise intraoperative measurement is strongly advised. By virtue of a careful sizing, the collar of the Valsalva graft covers comfortably the entire valve sewing ring ensuring excellent hemostatic property. The size of the Valsalva graft should be decided after measuring the “true” external sewing ring diameter of the prosthesis. We have obtained written informed consent from this patient for reporting. The institutional review board deemed the study exempt because the same technique was already used in the presence of mechanical valve.
  5 in total

1.  Facilitated aortic root substitution after aortic valve replacement: technique and results of the prosthesis-sparing operation.

Authors:  Nicola Luciani; Amedeo Anselmi; Raphael de Geest; Franco Glieca; Gianfederico Possati
Journal:  J Thorac Cardiovasc Surg       Date:  2009-05-31       Impact factor: 5.209

2.  The completion Bentall procedure.

Authors:  Ramin Malekan; David Spielvogel; Paul C Saunders; Steven L Lansman; Randall B Griepp
Journal:  Ann Thorac Surg       Date:  2011-07       Impact factor: 4.330

3.  Optimized use of the "skirt" of the Valsalva graft for the completion Bentall.

Authors:  Raffaele Scaffa; Andrea Salica; Luca Weltert; Francesco Giosuè Irace; Lorenzo Guerrieri Wolf; Salvo D'Aleo; Alessandro Bellisario; Ruggero De Paulis
Journal:  Ann Thorac Surg       Date:  2021-03-06       Impact factor: 4.330

4.  Bentall procedure after previous aortic valve or complete root replacement: Usefulness of self-assembled aortic valve conduit.

Authors:  Paul P Urbanski; Fitsum Lakew; Witold Dinstak; Nicolas Heinz; Michael Zacher; Vadim Irimie; Wilko Reents
Journal:  J Thorac Cardiovasc Surg       Date:  2018-03-11       Impact factor: 5.209

5.  Aortic root substitution after aortic valve replacement: a prosthesis-sparing operation.

Authors:  Davide Pacini; Emmanuel Villa; Sofia Martin-Suarez; Roberto Di Bartolomeo
Journal:  Eur J Cardiothorac Surg       Date:  2005-04       Impact factor: 4.191