Bentall procedure after previous aortic valve or complete root replacement: Usefulness of self-assembled aortic valve conduit.

Paul P Urbanski1, Fitsum Lakew2, Witold Dinstak2, Nicolas Heinz2, Michael Zacher2, Vadim Irimie2, Wilko Reents2.   

Abstract

OBJECTIVES: The aim of this study was to evaluate surgical results of complete aortic root replacement using self-assembled valve composite graft in the setting of destroyed aortic annulus after previous valve replacement.
METHODS: Aortic root pathology being addressed by complete root replacement was combined with partial or complete absence of annular tissue in 112 consecutive patients. Eighty-eight had undergone a previous replacement of the aortic valve and 24 had undergone root replacement with a valved conduit. Altogether, 31 patients (27.7%) presented with acute endocarditis, which was the indication for surgery in 75% of patients with prior root replacement. In all patients, the root replacement or re-replacement was performed with a self-assembled valved conduit using mechanical (n = 74) or, in patients with an advanced age, biological (n = 38) valve prostheses.
RESULTS: In-hospital mortality was 11.6%, including a 30-day mortality of 6.3%. Resternotomy for bleeding was necessary in 5.4% of patients and about one-quarter did not need any blood transfusion. Estimated survival at 1, 5, and 10 years was 84.8% ± 3.4%, 75.7% ± 4.3%, and 57.1% ± 6.5%, respectively. Freedom from any valve-related events at 10 years was 86.2% ± 4.1%. During the follow-up time (mean, 63 ± 47 months), there was only 1 reoperation necessary 9 years after surgery (replacement of deteriorated biological valve prosthesis within the vascular tube leaving the conduit untouched).
CONCLUSIONS: A self-assembled composite graft allows safe proximal fixation of the conduit in patients with destroyed aortic annulus, resulting in sufficient proximal anastomosis and a very low incidence of aorta-related reoperations.
Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  aortic redo surgery; aortic root; aortic valve; composite graft; endocarditis

Mesh:

Year:  2018        PMID: 29609891     DOI: 10.1016/j.jtcvs.2018.01.105

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  2 in total

1.  Simple completion Bentall procedure of preserving aortic bioprosthesis after aortic valve replacement.

Authors:  Soichiro Henmi; Raffaele Scaffa; Giulio Folino; Ruggero De Paulis
Journal:  JTCVS Tech       Date:  2022-04-27

2.  Clinical analysis of redo aortic root replacement after cardiac surgery: a retrospective study.

Authors:  Jianying Deng; Qianjin Zhong
Journal:  J Cardiothorac Surg       Date:  2021-07-28       Impact factor: 1.637

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.