Literature DB >> 35967227

Atrioesophageal fistula-A focus on preventing a devastating complication.

Christopher Joseph1, Jose Nazari2, Mark Metzl2.   

Abstract

Entities:  

Year:  2022        PMID: 35967227      PMCID: PMC9366206          DOI: 10.1016/j.xjtc.2022.03.003

Source DB:  PubMed          Journal:  JTCVS Tech        ISSN: 2666-2507


× No keyword cloud information.
To the Editor: C.J. reported internship with Attune Medical. M.M. reported honoraria and consulting from Abbott, Biosense Webster, Attune Medical, Medtronic, Sanofi Aventis, and Philips. J.Z. reported no conflicts of interest. The Journal policy requires editors and reviewers to disclose conflicts of interest and to decline handling or reviewing manuscripts for which they may have a conflict of interest. The editors and reviewers of this article have no conflicts of interest. In their case report, Felmly and Gibney illustrate the devastating consequences of uncontrolled thermal ablation for atrial fibrillation, but with a successful outcome due to high-quality management. Although rare, as emphasized in the commentaries by Shen and by Alvarado and Worrell, atrioesophageal (AE) fistulas represent a significant threat to patient mortality following catheter ablation for atrial fibrillation. AE fistulas represent 15.6% of patient deaths within 30 days of catheter ablation. As mentioned by Shen, with the nearly 10-fold rise in performed catheter ablations for the treatment of atrial fibrillation between 2000 and 2013, there will likely be hundreds of AE fistulas yearly., Given the report presented by Felmly and Gibney and recent trends in electrophysiology, it is clear that prevention of AE fistulas should be a priority for both electrophysiologists and thoracic surgeons alike. AE fistulas present a unique challenge, as they are difficult to diagnose, leading to late management and worsened prognosis, thus demanding proactive safety measures to prevent such a devastating complication. Active cooling has recently been shown to offer greater protection against thermal ablation injury as compared with the industry standards such as esophageal temperature monitoring or balloon deviation. The IMPACT study demonstrated a significant reduction in thermal esophageal injury, and thousands of uses have now been performed without the development of an AE fistula., Therefore, broader use of active cooling would reduce the burden of AE fistula resulting from thermal ablation. In the case of management, the complexity of repair often coincides with the size of fistula as well as the time to diagnosis. As seen in recent repair technique literature, a larger defect likely necessitates multiple repair attempts as well as a possible esophageal diversion. Consequently, it is reasonable to assume that reduction in the degree of thermal injury through evidence-based techniques such as active cooling of the esophagus will lead to both a reduction in the incidence of AE fistulas as well as a reduction of the severity of the defect. Given the aforementioned evidence, the use of active cooling to compensate for the thermal insult of catheter ablation should be advocated for by electrophysiologists and thoracic surgeons alike as this preventative measure will reduce incidence and severity of AE fistulas.
  8 in total

1.  Catheter Ablation for Cardiac Arrhythmias: Utilization and In-Hospital Complications, 2000 to 2013.

Authors:  Seyed Mohammadreza Hosseini; Guy Rozen; Ahmed Saleh; Jeena Vaid; Yitschak Biton; Kasra Moazzami; E Kevin Heist; Moussa C Mansour; M Ihsan Kaadan; Mark Vangel; Jeremy N Ruskin
Journal:  JACC Clin Electrophysiol       Date:  2017-08-02

2.  Prevalence and causes of fatal outcome in catheter ablation of atrial fibrillation.

Authors:  Riccardo Cappato; Hugh Calkins; Shih-Ann Chen; Wyn Davies; Yoshito Iesaka; Jonathan Kalman; You-Ho Kim; George Klein; Andrea Natale; Douglas Packer; Allan Skanes
Journal:  J Am Coll Cardiol       Date:  2009-05-12       Impact factor: 24.094

3.  Commentary: How far would you go?

Authors:  Christine E Alvarado; Stephanie G Worrell
Journal:  J Thorac Cardiovasc Surg       Date:  2021-07-01       Impact factor: 5.209

4.  Active esophageal cooling for the prevention of thermal injury during atrial fibrillation ablation: a randomized controlled pilot study.

Authors:  Cory M Tschabrunn; Sara Attalla; Jonathan Salas; David S Frankel; Matthew C Hyman; Emily Simon; Tiffany Sharkoski; David J Callans; Gregory E Supple; Saman Nazarian; David Lin; Robert D Schaller; Sanjay Dixit; Francis E Marchlinski; Pasquale Santangeli
Journal:  J Interv Card Electrophysiol       Date:  2021-02-23       Impact factor: 1.900

5.  Commentary: The rising storm of atrioesophageal fistulae after catheter ablation for atrial fibrillation.

Authors:  K Robert Shen
Journal:  JTCVS Tech       Date:  2020-12-25

6.  Randomized comparison of oesophageal protection with a temperature control device: results of the IMPACT study.

Authors:  Lisa W M Leung; Abhay Bajpai; Zia Zuberi; Anthony Li; Mark Norman; Riyaz A Kaba; Zaki Akhtar; Banu Evranos; Hanney Gonna; Idris Harding; Manav Sohal; Nawaf Al-Subaie; John Louis-Auguste; Jamal Hayat; Mark M Gallagher
Journal:  Europace       Date:  2021-02-05       Impact factor: 5.214

7.  Atrioesophageal fistula from percutaneous ablation for atrial fibrillation.

Authors:  Lloyd M Felmly; Barry C Gibney
Journal:  JTCVS Tech       Date:  2020-11-26

8.  Surgical technique for atrial-esophageal fistula repair after catheter ablation: An underrecognized complication.

Authors:  Brandon A Guenthart; Beatrice Sun; Andreas De Biasi; Michael P Fischbein; Douglas Z Liou
Journal:  JTCVS Tech       Date:  2020-08-05
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.