| Literature DB >> 35956198 |
Stefan Soltesz1, Jan Thomas1, Michael Anapolski2, Guenter Karl Noé2.
Abstract
The new acceleromyograph TOF 3D was compared with the established TOF Watch SX in patients undergoing elective laparoscopic gynecological surgery. Neuromuscular transmission was assessed by simultaneous recording with both devices. Measurements were performed simultaneously at the left and the right M. adductor pollicis (Group A, 25 patients), or the M. corrugator supercilii (Group CS, 25 patients). The repeatability, time course, and limits of agreement (Bland-Altman) were compared. The primary endpoint was the 90% train-of-four recovery time (TOFR 0.9). Other endpoints included onset time of block, maximum T1 depression, time to 25% T1 recovery, the recovery time course of T1 response, and TOF ratio, respectively. In group CS, the repeatability coefficient of the TOF 3D was lower (4.66 (1.6)) than of the TOF Watch SX (6.02 (1.9); p = 0.026). In group A, the onset of the block was faster when measured by the TOF 3D (98.7 (30) s vs. 112.2 (36) s (mean (SD)); p = 0.032). In group A, time to recovery to a TOFR of 90% was measured earlier by the TOF 3D (bias -0.71 min, limits of agreement from -8.94 to +7.51 min). The TOF 3D provides adequate information with high precision and sensitivity. It is suitable even for measurement sites with small muscle contractions such as the M. corrugator supercilii.Entities:
Keywords: acceleromyography; neuromuscular block; neuromuscular monitoring
Year: 2022 PMID: 35956198 PMCID: PMC9369732 DOI: 10.3390/jcm11154583
Source DB: PubMed Journal: J Clin Med ISSN: 2077-0383 Impact factor: 4.964
Figure 1Consort flow diagram of the patients.
Baseline responses.
| Group | n | Stimulation (mA) | Stimulation (mA) | Baseline TOFR | Baseline TOFR | Repeatability | Repeatability |
|---|---|---|---|---|---|---|---|
| M. adductor | 25 | 48.8 ± 10.3 | 48.5 ± 10.0 | 108.8 ± 6.1 | 106.5 ± 5.7 | 4.08 ± 1.3 | 3.95 ± 1.2 |
| M. corrugator | 25 | 48.0 ± 14.5 | 41.5 ± 9.7 | 109.3 ± 13.5 | 113.0 ± 9.9 | 6.02 ± 1.9 | 4.66 ± 1.6 * |
TOFR: Train-of-four Rate; *: p = 0.026 for SX vs. 3D. Values are presented as mean ± SD.
Time course of the neuromuscular block: Reappearance of T1 –T4, DUR 25%, TOFR 90%, TOFR 100%. Values are presented in min ± SD.
| Group | T1
| T1
| T2
| T2
| T3
| T3 | T4
| T4
| DUR | DUR | TOFR | TOFR | TOFR 100% | TOFR |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| M. adductor | 26.3 | 24.9 | 31.5 | 29,7 | 34.7 | 32.9 | 36.1 | 34.1 | 42.1 | 39.9 | 59.1 | 55.3 | 61.0 | 61.5 |
| P value for SX vs. 3D | 0.005 | 0.005 | 0.003 | 0.011 | < 0.001 | |||||||||
| M. corrugator | 17.0 | 15.4 | 23.3 | 22.9 | 27.3 | 26.2 | 36.1 | 34.1 | 31.5 | 31.3 | 45.0 | 43.7 | 45.7 | 47.7 |
| P value for SX vs. 3D | 0.043 | 0.039 | 0.011 | |||||||||||
T1–T4: Time between injection of rocuronium and reappearance of T1, T2, T3 or T4; DUR25%: time between injection of rocuronium and recovery to 25% twitch height; TOFR 90% and TOFR 100%: time between injection of rocuronium to 90% or 100% train-of-four recovery, respectively.
Figure 2(a,b) Time course of train-of-four ratio (TOFR) vs. time for both acceleromyographs at the M. adductor pollicis (a) and the M. corrugator supercilii (b). Rocuronium was injected at time “0”. Black dots: TOF Watch SX. White dots: TOF 3D. *: p = 0.043 for 3D vs. SX. #: p = 0.0028 for 3D vs. SX.
Figure 3(a–c). Bland-Altman plots of the differences between TOF Watch SX and TOF 3D. Black horizontal line in the middle: bias; blue upper and lower line: limits of agreement (±1.96 SD); (a) Onset: time (min) between the beginning of injection of rocuronium and maximum T1 depression; (b) DUR25%: time (min) between administration of rocuronium and recovery to 25% twitch height; (c) TOFR 90%: time (min) from an injection of rocuronium to 90% train-of-four recovery.