Three-Dimensional Echocardiography Based on Automation and Machine Learning Principles and the Renaissance of Cardiac Morphometry.

Andrea Barbieri1, Mauro Pepi2.   

Abstract

Today, the core component of all transthoracic echocardiography reports is the quantification of cardiac chamber size and function using advanced echocardiography modalities such as three-dimensional echocardiography (3DE), in line with the rising demand for quantifications of cardiac chambers with high measurement accuracy and reproducibility [...].

Entities:  

Year:  2022        PMID: 35955974      PMCID: PMC9369091          DOI: 10.3390/jcm11154357

Source DB:  PubMed          Journal:  J Clin Med        ISSN: 2077-0383            Impact factor:   4.964


Today, the core component of all transthoracic echocardiography reports is the quantification of cardiac chamber size and function using advanced echocardiography modalities such as three-dimensional echocardiography (3DE), in line with the rising demand for quantifications of cardiac chambers with high measurement accuracy and reproducibility. Competing against this need is the additional constraints on the echocardiography laboratory’s time and resources, such as the rise in the average study’s image acquisition rate and the requirement to include new measures. There is an understandable tendency to forego traditional image capturing due to concerns about missing corroborating information, as highlighted in a recent EACVI Scientific Initiatives Committee survey. Surprisingly, several centers that do not regularly employ 3DE in the morpho-functional evaluation of cardiac patients reported that they did not think the 3DE technique added any extra value [1]. Against this background, the real question is how automated morphology and function assessment with the assistance of artificial intelligence technology will change our practice, considering that in many cases, cardiac morphometry is still estimated qualitatively by eye or quantitatively using conventional bi-dimensional echocardiography (2DE). It is always helpful to remind ourselves that the visual interpretation of cardiac chamber volumes and function has well-known shortcomings, independent of the operators’ experience [2]. As a result, referring physicians increasingly expect quantitative assessments. However, reading several echocardiograms is time-consuming and laborious because of the vast volume of information. Notably, manual measurements are known to differ significantly amongst readers. The poor acoustic window, the need for geometric modeling, and errors caused by foreshortened views, mistiming end-systole, or mistracing of the endocardial border represent notable limitations of conventional 2DE. Even minor variations affect downstream calculations of cardiac chambers [3]. Despite filtering out every known source of error, one of the critical factors of interobserver variability is the operator’s impression of the blood–tissue interface, with the existence of trabeculation being the primary source of disagreement, considering that trabeculae and papillary muscles accounted for as much as 23% of left ventricular (LV) volume [4]. Indeed, the LV volume assessment does change significantly depending on whether the operator draws the boundary by the blood tissue interface (i.e., at the tip of the trabeculation) or on the compact myocardium [5]. The latter value is more similar to the mean value determined by cardiac magnetic resonance imaging, which is presently regarded as the gold standard for quantifying heart chambers [6]. Delineation errors in these anatomic features can significantly impact LV and right ventricular (RV) volume and mass assessments, depending on how readily trabeculae and papillary muscles can be distinguished from myocardial tissue. Of note, differences as small as 1 mm in tracing the LV border produced 11% differences in volume measurements [4]. Individuals and institutions must standardize their LV border tracing practices to address this issue. The use of machine learning techniques to automate echocardiograms overcomes many of these drawbacks and may revolutionize the workflow in echocardiography laboratories, promoting the use of 3DE measurements in busy laboratories. One of the automation’s major advantages is its excellent reproducibility, able to reduce the gap in reliability between expert and novice readers; given the same image, a completely automated software will always output the same endocardial border and volume. Other benefits of automation include reduced time and costs related to image acquisition, rapid analysis, and reporting [7]. Moreover, using an average of several observations to estimate chamber size or quantify velocities, gradients, or stroke volumes is helpful regardless of the underlying rhythm [8]. A meta-analysis shows that fully automated software outperforms semiautomated and manual software because individual interpreters’ positioning and editing endocardial contours introduce more substantial variability and bias [9]. However, 3DE-derived volumes are still underestimated in most patients because they cannot differentiate between compact myocardium and trabeculae, contributing to the persistent underestimation in values compared with cardiac magnetic resonance. Furthermore, the software still has difficulty accurately delineating the endocardial border of LV in some patients. For example, the shape and/or complex contraction patterns, such as multiple regional motion abnormality, are not in the training dataset [10]. Recently, a new generation of fully automated software based on an adaptive analytics algorithm has been developed for left-heart chamber quantification [11]. This novel technology appears to be feasible, fast, and reproducible [12,13,14,15]. The acquisition of LV foreshortened views is recognized by the current version of the software package, and several LV and left atrial (LA) function indices are automatically calculated from a single dataset in ~30″ [15]. Moreover, the user specifies where the final single endocardial border should be placed, allowing to bring the measurements obtained with 3DE ever closer to those obtained with cardiac magnetic resonance [12]. Simultaneously, incorporating 3DE into daily workflow necessitates the implementation of critical resources such as appropriate equipment (transducers, ultrasound machine, and software), patient selection, assimilation of 3DE protocols into current clinical routine, laboratory workflow adaptation, storage, and reporting. Once leadership and hospital administration have decided to acquire a 3DE system, the echo laboratory must establish an agreement on standardized 3DE methods. Our approach was to integrate 3DE within a 2DE protocol from the beginning if a 3DE probe was available and apply it routinely to all patients to evaluate left chambers and selectively for the right chambers. Our echo lab’s rate of acquiring a 3DE LV and LA volume is about 80%, including consecutive inpatient and outpatient studies [15,16]. Based on our and other [17] experiences, six major obstacles remain that prevent a wider spread of 3DE: (1) the underappreciation of the added clinical value of 3DE vs. conventional 2DE, (2) the finite number of 3DE probes available, (3) the need to organize a formal program of training and competency, (4) the presence of still unresolved technical issues of poor image quality, (5) the propriety algorithms to post-process and analyze 3DE datasets, and (6) the way to communicate the clinical significance of reporting changes from 2DE to 3DE, which remains to be defined. It is crucial to understand that every cut-off number we use to determine whether to recommend valve surgery, device installation, etc. comes from controlled randomized studies that employed 2DE to calculate LV ejection fraction values. Nonetheless, the reference values for left heart chamber volumes assessed with 3DE fully automated software and conventional 2DE are quite different and cannot be utilized interchangeably [18]. As a result, echocardiography reports must be produced differently depending on the method employed and referring physicians must understand distinct cut-off values to distinguish between normal and enlarged volumes and function. The creation of proprietary algorithms to post-process and analyze 3DE information poses an additional problem in multi-vendor echo labs, especially multi-site laboratories, where the staff must adapt to a different workflow. In our experience, the most critical clinical challenge is represented by the substantial underestimation of LV volumes (and stroke volume), as determined by 2DE, compared to the values obtained with 3DE, especially in patients with dilated ventricles. When 3DE is performed during follow-up on patients whose earlier echo examination had been carried out with 2DE, our laboratory labels these data resulting from 3DE or 2DE as not directly comparable measurements. However, perhaps the major limitation for the spread of 3DE is represented by the still too popular belief that artificial intelligence threatens our professionalism. The practice of echocardiography is seen as a combination of talent and science strongly dependent on the skills and experience of the operators. Conversely, we believe that the recent development of novel techniques to make an automated quantitative analysis of 3DE based on machine learning principles offers a “game-changer” opportunity to reduce the workload in our busy echo lab, improving the reproducibility and repeatability of the measurements [19]. Significantly, the high-performance, automated, adaptive analytics software offers the most accurate and reproducible quantitation of volumes, geometry, and function of the left heart and has the great potential to revolutionize our practice expanding potential clinical applications in ways that were inconceivable until recently. Indeed, we have at our disposal new algorithms for 3DE LV mass analysis [16]. Furthermore, these algorithms overcome many pitfalls of the conventional 2DE volumetric method, for example, for proper quantification of the mitral regurgitation, and the correct diagnosis of the low-flow state [20]. In addition, they eliminate the geometric assumptions regarding the LA geometry and the systematic foreshortening of the LA apical view [21,22]. The application of the advanced echocardiography modalities is equally indicated in the evaluation of the right chambers considering that the functional assessment of the RV on 2DE is primarily based on qualitative measures that are relatively easy to measure but subject to many limitations [23]. Recent improvements in 3DE semiautomated algorithms software analysis on board the echocardiographic scanners allow for fast and reproducible RV [24] and right atrial volumetric analysis [25]. It is easily predictable that, as data accumulate and user-friendly software packages become available, 3DE will gradually become common even in the morphometrics assessment of the RV [26] and RV–pulmonary arterial coupling [27]. However, embracing new technology such as 3DE necessitates a willingness to adapt based on the recognition that it adds value to our clinical practice and is simple to use, but too many echocardiographers are still unaware that with the new automated 3DE tools, it is possible to obtain a quantitative morphometric evaluation of all heart chambers on top of conventional 2DE in 38 ± 0.16 s, with a total acquisition time of 14.24 ± 3.32 min [28]. We will therefore have to be prepared for the inevitable conceptual revolution already underway in which physicians will be called to start their interpretation of transthoracic echocardiography with multiple automatically measured static/dynamic numerical indices alongside the images. While challenges remain, the transition from the 2DE to 3DE era is already real in 2022 and represents an exciting research field that is yet to be explored. Beyond validation of new analysis software packages, the next inevitable step of 3DE research should be establishing reference values and outcome data for multiparametric data cut-offs in various disease states. In a related manner, setting normal reference values is necessary for 3DE to gain acceptance in clinical practice [29].
  29 in total

1.  From secondary to tertiary mitral regurgitation: the paradigm shifts, but uncertainties remain.

Authors:  Antonio Landi; Francesco Fulvio Faletra; Anna Giulia Pavon; Giovanni Pedrazzini; Marco Valgimigli
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2021-07-20       Impact factor: 6.875

2.  Machine learning based automated dynamic quantification of left heart chamber volumes.

Authors:  Akhil Narang; Victor Mor-Avi; Aldo Prado; Valentina Volpato; David Prater; Gloria Tamborini; Laura Fusini; Mauro Pepi; Neha Goyal; Karima Addetia; Alexandra Gonçalves; Amit R Patel; Roberto M Lang
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2019-05-01       Impact factor: 6.875

3.  Correlation of trabeculae and papillary muscles with clinical and cardiac characteristics and impact on CMR measures of LV anatomy and function.

Authors:  Michael L Chuang; Philimon Gona; Gilion L T F Hautvast; Carol J Salton; Susan J Blease; Susan B Yeon; Marcel Breeuwer; Christopher J O'Donnell; Warren J Manning
Journal:  JACC Cardiovasc Imaging       Date:  2012-11

4.  Intervendor Consistency and Accuracy of Left Ventricular Volume Measurements Using Three-Dimensional Echocardiography.

Authors:  Denisa Muraru; Antonella Cecchetto; Umberto Cucchini; Xiao Zhou; Roberto M Lang; Gabriella Romeo; Mani Vannan; Sorina Mihaila; Marcelo Haertel Miglioranza; Sabino Iliceto; Luigi P Badano
Journal:  J Am Soc Echocardiogr       Date:  2017-12-08       Impact factor: 5.251

5.  EACVI survey on standardization of cardiac chambers quantification by transthoracic echocardiography.

Authors:  Nina Ajmone Marsan; Blazej Michalski; Matteo Cameli; Tomaz Podlesnikar; Robert Manka; Marta Sitges; Marc R Dweck; Kristina H Haugaa
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2020-02-01       Impact factor: 6.875

6.  Imaging assessment of the right atrium: anatomy and function.

Authors:  Roberto M Lang; Matteo Cameli; Leila E Sade; Francesco F Faletra; Federico Fortuni; Alexia Rossi; Laurie Soulat-Dufour
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2022-06-21       Impact factor: 6.875

7.  Normal Values of Left Ventricular Size and Function on Three-Dimensional Echocardiography: Results of the World Alliance Societies of Echocardiography Study.

Authors:  Karima Addetia; Tatsuya Miyoshi; Vivekanandan Amuthan; Rodolfo Citro; Masao Daimon; Pedro Gutierrez Fajardo; Ravi R Kasliwal; James N Kirkpatrick; Mark J Monaghan; Denisa Muraru; Kofo O Ogunyankin; Seung Woo Park; Ricardo E Ronderos; Anita Sadeghpour; Gregory M Scalia; Masaaki Takeuchi; Wendy Tsang; Edwin S Tucay; Ana Clara Tude Rodrigues; Yun Zhang; Niklas Hitschrich; Michael Blankenhagen; Markus Degel; Marcus Schreckenberg; Victor Mor-Avi; Federico M Asch; Roberto M Lang
Journal:  J Am Soc Echocardiogr       Date:  2021-12-14       Impact factor: 7.722

8.  3D echocardiographic reference ranges for normal left ventricular volumes and strain: results from the EACVI NORRE study.

Authors:  Anne Bernard; Karima Addetia; Raluca Dulgheru; Luis Caballero; Tadafumi Sugimoto; Natela Akhaladze; George D Athanassopoulos; Daniele Barone; Monica Baroni; Nuno Cardim; Andreas Hagendorff; Krasimira Hristova; Federica Ilardi; Teresa Lopez; Gonzalo de la Morena; Bogdan A Popescu; Martin Penicka; Tolga Ozyigit; Jose David Rodrigo Carbonero; Nico van de Veire; Ralph Stephan Von Bardeleben; Dragos Vinereanu; Jose Luis Zamorano; Christophe Martinez; Julien Magne; Bernard Cosyns; Erwan Donal; Gilbert Habib; Luigi P Badano; Roberto M Lang; Patrizio Lancellotti
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2017-04-01       Impact factor: 6.875

9.  Echocardiographic Left Ventricular Mass Assessment: Correlation between 2D-Derived Linear Dimensions and 3-Dimensional Automated, Machine Learning-Based Methods in Unselected Patients.

Authors:  Andrea Barbieri; Francesca Bursi; Giovanni Camaioni; Anna Maisano; Jacopo Francesco Imberti; Alessandro Albini; Gerardo De Mitri; Francesca Mantovani; Giuseppe Boriani
Journal:  J Clin Med       Date:  2021-03-19       Impact factor: 4.241

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.