Short and long term corneal biomechanical analysis after overnight orthokeratology.

Amelia Nieto-Bona1, Paloma Porras-Ángel1, Adela Elena Ayllón-Gordillo1, Gonzalo Carracedo1, David P Piñero2.   

Abstract

AIM: To investigate the short and long term corneal biomechanical changes after overnight orthokeratology (OK) and compare them with those occurring in subjects not wearing contact lenses.
METHODS: Retrospective case control study enrolling 54 subjects that were divided into three groups 18 subjects each: control group (CG), short term (15 nights) OK (STOK) group, and long term (more than 1y of OK wear) OK (LTOK) group. Corneal biomechanics were characterized using the CorVis® ST system (Oculus), recording parameters such as time [first/second applanation time (AT1, AT2)], speed [velocity of corneal apex at the first/second applanation time (AV1, AV2)], and amplitude of deformation (AD1, AD2) in the first and second corneal flattening, corneal stiffness (SPA1), biomechanically corrected intraocular pressure (bIOP) and corneal (CBI) and tomographic biomechanical indices (TBI).
RESULTS: Significantly lower AD1 and standard deviate on of Ambrosio's relational average thickness related to the horizontal profile (ARTh) values were found in the OK groups compared to CG (P<0.05). Likewise, significantly higher values of CBI were found in STOK and LTOK groups compared to CG (P<0.01). No significant differences between groups were found in integrated radius index (P=0.24), strain stress index (P=0.22), tomographic biomechanical index (P=0.91) and corneal stiffness parameter (SPA1, P=0.97). Significant inverse correlations were found between corneal thickness and CBI in STOK (r=-0.90, P<0.01) and LTOK groups (r=-0.71, P<0.01).
CONCLUSION: OK does not seem to alter significantly the corneal biomechanical properties, but special care should be taken when analyzing biomechanical parameters influenced by corneal thickness such as amplitude of deformation, ARTh or CBI, because they change significantly after treatment but mainly due to the reduction and pachymetric progression induced by the corneal molding secondary to OK treatment. International Journal of Ophthalmology Press.

Entities:  

Keywords:  CorVis® ST; corneal biomechanical index; corneal biomechanics; overnight orthokeratology; pachymetry; tomographic biomechanical index

Year:  2022        PMID: 35919327      PMCID: PMC9318079          DOI: 10.18240/ijo.2022.07.13

Source DB:  PubMed          Journal:  Int J Ophthalmol        ISSN: 2222-3959            Impact factor:   1.645


  23 in total

Review 1.  Corneal biomechanics: a review.

Authors:  David P Piñero; Natividad Alcón
Journal:  Clin Exp Optom       Date:  2014-12-02       Impact factor: 2.742

2.  Postoperative corneal biomechanics and influencing factors during femtosecond-assisted laser in situ keratomileusis (FS-LASIK) and laser-assisted subepithelial keratomileusis (LASEK) for high myopia.

Authors:  Mingna Liu; Weiyun Shi; Xin Liu; Na Li; Tong Chen; Hua Gao
Journal:  Lasers Med Sci       Date:  2021-04-23       Impact factor: 3.161

3.  Short-term effects of overnight orthokeratology on corneal epithelial permeability and biomechanical properties.

Authors:  Thao N Yeh; Harry M Green; Yixiu Zhou; Julie Pitts; Britney Kitamata-Wong; Sophia Lee; Shiyin L Wang; Meng C Lin
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-06-06       Impact factor: 4.799

4.  Comparison of Corneal Tomography and a New Combined Tomographic Biomechanical Index in Subclinical Keratoconus.

Authors:  Tommy C Y Chan; Yu Meng Wang; Marco Yu; Vishal Jhanji
Journal:  J Refract Surg       Date:  2018-09-01       Impact factor: 3.573

5.  Comparison of Corneal Deformation Parameters in Keratoconic and Normal Eyes Using a Non-contact Tonometer With a Dynamic Ultra-High-Speed Scheimpflug Camera.

Authors:  Ryan N Mercer; George O Waring; Cynthia J Roberts; Vishal Jhanji; Yumeng Wang; Joao S Filho; Richard A Hemings; Karolinne M Rocha
Journal:  J Refract Surg       Date:  2017-09-01       Impact factor: 3.573

6.  Effectiveness of the Goldmann Applanation Tonometer, the Dynamic Contour Tonometer, the Ocular Response Analyzer and the Corvis ST in Measuring Intraocular Pressure following FS-LASIK.

Authors:  Fangjun Bao; Wei Huang; Rong Zhu; Nanji Lu; Yuan Wang; Hechen Li; Songan Wu; Huini Lin; Junjie Wang; Xiaobo Zheng; JinHai Huang; Yiyu Li; Qinmei Wang; Ahmed Elsheikh
Journal:  Curr Eye Res       Date:  2019-12-26       Impact factor: 2.424

Review 7.  Optical changes and visual performance with orthokeratology.

Authors:  Augustine N Nti; David A Berntsen
Journal:  Clin Exp Optom       Date:  2019-08-04       Impact factor: 2.742

8.  Pilot study on the influence of corneal biomechanical properties over the short term in response to corneal refractive therapy for myopia.

Authors:  José Manuel González-Méijome; César Villa-Collar; António Queirós; Jorge Jorge; Manuel A Parafita
Journal:  Cornea       Date:  2008-05       Impact factor: 2.651

9.  Association between long-term orthokeratology responses and corneal biomechanics.

Authors:  Andrew K C Lam; Ying Hon; Stanley Y Y Leung; Lu Shu-Ho; Jones Chong; David C C Lam
Journal:  Sci Rep       Date:  2019-08-29       Impact factor: 4.379

Review 10.  Orthokeratology in Moderate Myopia: A Study of Predictability and Safety.

Authors:  Kirti Singh; Mainak Bhattacharyya; Abhishek Goel; Ritu Arora; Nikhil Gotmare; Himshikha Aggarwal
Journal:  J Ophthalmic Vis Res       Date:  2020-04-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.