Literature DB >> 3591011

Positive and negative ion mass spectrometry of benzophenones, the acid-hydrolysis products of benzodiazepines.

O Suzuki, H Hattori, M Asano, T Takahashi, H Brandenberger.   

Abstract

Positive electron impact (EI), positive chemical ionization (CI), and negative CI mass spectra of 14 benzophenones are presented. In the positive EI mode, intense molecular peaks appeared for most compounds; some other peaks due to splitting at both sides of the carbonyl group also appeared. In the positive CI mode, [M + 1]+ quasi-molecular ions together with [M + C2H5]+ peaks were observed for all compounds; some fragment peaks were common to those in the positive EI mode. In the negative CI mode, the spectra were much simpler than those in the positive EI or CI mode. In the 1 Torr negative CI mode, some spectra showed only single molecular anions; in the 0.01 Torr negative CI mode, halogen or nitro peaks appeared in addition to the molecular anions. An extraction procedure for benzophenones from human urine and plasma after heating in strong acid, and their separation by gas chromatography (GC) are also presented to serve for their actual identification by GC/mass spectrometry.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3591011     DOI: 10.1007/bf00200380

Source DB:  PubMed          Journal:  Z Rechtsmed        ISSN: 0044-3433


  5 in total

1.  The gas chromatography mass spectrometry of the major metabolites of flurazepam.

Authors:  A J Clatworthy; L V Jones; M J Whitehouse
Journal:  Biomed Mass Spectrom       Date:  1977-08

2.  The decomposition of benzodiazepines during analysis by capillary gas chromatography/mass spectrometry.

Authors:  J R Joyce; T S Bal; R E Ardrey; H M Stevens; A C Moffat
Journal:  Biomed Mass Spectrom       Date:  1984-06

3.  Determination of 1,4- and 1,5-benzodiazepines in urine using a computerized gas chromatographic-mass spectrometric technique.

Authors:  H Maurer; K Pfleger
Journal:  J Chromatogr       Date:  1981-03-13

4.  [GLC-data of 19 hydrolysis-derivatives rised from 12 important benzodiazepines and 17 main-metabolites (author's transl)].

Authors:  H Schütz; V Westenberger
Journal:  Z Rechtsmed       Date:  1978-09-28

5.  Negative ion mass spectrometry of phenothiazines.

Authors:  R Ryhage; H Brandenberger
Journal:  Biomed Mass Spectrom       Date:  1978-11
  5 in total
  2 in total

Review 1.  Modern screening strategies in analytical toxicology with special regard to new benzodiazepines.

Authors:  H Schütz
Journal:  Z Rechtsmed       Date:  1988

2.  [Screening for tetracyclic benzodiazepines using EMIT-st (benzodiazepines) and TDx].

Authors:  H Schütz; W R Schneider
Journal:  Z Rechtsmed       Date:  1987
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.