Literature DB >> 35900997

Combining ADMIRE and MV to Improve Image Quality.

Siegfried Schlunk, Brett Byram.   

Abstract

Aperture domain model image reconstruction (ADMIRE) is a frequency-domain, model-based beamformer, in part designed for removing reverberation and off-axis clutter. Minimum variance (MV) is alternatively designed to reduce off-axis interference and improve lateral resolution. MV is known to be less effective in high incoherent noise scenarios, and its performance in the presence of reverberation has not been evaluated. By implementing ADMIRE before MV, the benefits of both these beamformers can be achieved. In this article, the assumptions of MV are discussed, specifically their relationship to reverberation clutter. The use of ADMIRE as a preprocessing step to suppress noise from simulations with linear scanning and in vivo curvilinear kidney data is demonstrated, and both narrowband and broadband implementations of MV are applied. With optimal parameters, ADMIRE + MV demonstrated sizing improvements over MV alone by an average of 52.1% in 0-dB signal-to-clutter ratio reverberation cyst simulations and 14.5% in vivo while improving the contrast ratio compared to ADMIRE alone by an average of 15.1% in simulations and 14.0% in vivo. ADMIRE + MV demonstrated a consistent improvement compared to DAS, MV, and ADMIRE both in terms of sizing and contrast ratio.

Entities:  

Mesh:

Year:  2022        PMID: 35900997      PMCID: PMC9484307          DOI: 10.1109/TUFFC.2022.3194548

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   3.267


  32 in total

1.  Adaptive beamforming for nonstationary arrays.

Authors:  Michael V Greening; Jane E Perkins
Journal:  J Acoust Soc Am       Date:  2002-12       Impact factor: 1.840

2.  Eigenspace-based minimum variance beamforming applied to medical ultrasound imaging.

Authors:  Babak Mohammadzadeh Asl; Ali Mahloojifar
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2010-11       Impact factor: 2.725

3.  Time-domain optimized near-field estimator for ultrasound imaging: initial development and results.

Authors:  F Viola; M A Ellis; W F Walker
Journal:  IEEE Trans Med Imaging       Date:  2008-01       Impact factor: 10.048

4.  Speckle decorrelation due to two-dimensional flow gradients.

Authors:  B H Friemel; L N Bohs; K R Nightingale; G E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1998       Impact factor: 2.725

5.  Broadband minimum variance beamforming for ultrasound imaging.

Authors:  Iben Kraglund Holfort; Fredrik Gran; Jørgen Arendt Jensen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-02       Impact factor: 2.725

6.  Benefits of minimum-variance beamforming in medical ultrasound imaging.

Authors:  Johan-Fredrik Synnevag; Andreas Austeng; Sverre Holm
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-09       Impact factor: 2.725

7.  Eigenspace based minimum variance beamforming applied to ultrasound imaging of acoustically hard tissues.

Authors:  Saeed Mehdizadeh; Andreas Austeng; Tonni F Johansen; Sverre Holm
Journal:  IEEE Trans Med Imaging       Date:  2012-08-01       Impact factor: 10.048

8.  The Generalized Contrast-to-Noise Ratio: A Formal Definition for Lesion Detectability.

Authors:  Alfonso Rodriguez-Molares; Ole Marius Hoel Rindal; Jan D'hooge; Svein-Erik Masoy; Andreas Austeng; Muyinatu A Lediju Bell; Hans Torp
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-11-29       Impact factor: 2.725

9.  A model and regularization scheme for ultrasonic beamforming clutter reduction.

Authors:  Brett Byram; Kazuyuki Dei; Jaime Tierney; Douglas Dumont
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-11       Impact factor: 2.725

10.  Histogram Matching for Visual Ultrasound Image Comparison.

Authors:  Nick Bottenus; Brett C Byram; Dongwoon Hyun
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-04-26       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.