Literature DB >> 35875292

Verification of Shoulder External Rotators Strength Measurement Using a Suspension Scale.

Atsushi Ueda1, Yasuhiro Mitani2, Hitoshi Koda2, Toshimitsu Omine2, Ryuta Inada3, Naoyuki Konishi4, Shunsai Mori5.   

Abstract

Background Of the shoulder external rotators, the infraspinatus and teres minor are the key muscles that contribute to the dynamic stability of the shoulder. It is crucial to properly measure the strength values to evaluate muscle function and training load for shoulder external rotators. A suspension scale (SPS) can measure the mass of the suspended object, and it may be possible to apply it to measure strength. However, the utility of strength measurements using an SPS has not been clarified in previous studies. In this study, we aimed to investigate the intra-rater reliability of measuring the strength of shoulder external rotators using an SPS and the relationship between strength measurement using an SPS and a handheld dynamometer (HHD). Methodology The participants were 10 healthy males with 20 shoulders (24.5 ± 2.5 years old; height = 172.8 ± 5.4 cm; weight = 69.6 ± 8.1 kg). Upper extremity strength was measured at 90° shoulder abduction, 90° external rotation, 0° horizontal adduction/abduction, 90° elbow flexion, and 0° forearm pronation/supination in the prone position. The isometric strength of shoulder external rotation was measured with the SPS and HHD, and one examiner measured the maximum strength value. The intra-rater reliability of the two methods using SPS and HHD was evaluated using the intraclass correlation coefficient (ICC1,2), standard error of measurement (SEM), minimum detectable change (MDC), and Bland-Altman analysis. The relationship between the SPS and HHD was calculated as the correlation coefficient between the strength values of SPS and HHD. Results The intra-rater reliability of the strength measurement of shoulder external rotators using SPS was ICC1,2 0.98 (95% confidence interval = 0.95-0.99), and SEM and MDC were 0.3 and 0.9, respectively. The measurements using SPS had no fixed and proportional biases. A significant positive correlation was observed between SPS and HHD (r = 0.94, p < 0.01). Conclusions The SPS is an alternative to the HHD for measuring the strength of shoulder external rotators. Thus, measuring the strength of shoulder external rotators using an SPS may be applied as a cost-effective and portable assessment method for shoulder function.
Copyright © 2022, Ueda et al.

Entities:  

Keywords:  measurement; portable device; reliability; shoulder; strength

Year:  2022        PMID: 35875292      PMCID: PMC9297343          DOI: 10.7759/cureus.26106

Source DB:  PubMed          Journal:  Cureus        ISSN: 2168-8184


  22 in total

Review 1.  Current concepts in the rehabilitation of the overhead throwing athlete.

Authors:  Kevin E Wilk; Keith Meister; James R Andrews
Journal:  Am J Sports Med       Date:  2002 Jan-Feb       Impact factor: 6.202

2.  A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research.

Authors:  Terry K Koo; Mae Y Li
Journal:  J Chiropr Med       Date:  2016-03-31

3.  Shoulder pain in the overhand or throwing athlete. The relationship of anterior instability and rotator cuff impingement.

Authors:  F W Jobe; R S Kvitne; C E Giangarra
Journal:  Orthop Rev       Date:  1989-09

4.  The effects of pressure biofeedback training on infraspinatus muscle activity and muscle thickness.

Authors:  Il-Young Yu; Yeon-Ki Choo; Mon-Hwan Kim; Jae-Seop Oh
Journal:  J Electromyogr Kinesiol       Date:  2018-01-31       Impact factor: 2.368

Review 5.  Biomechanics of overhand throwing with implications for injuries.

Authors:  G S Fleisig; S W Barrentine; R F Escamilla; J R Andrews
Journal:  Sports Med       Date:  1996-06       Impact factor: 11.136

6.  Concurrent Validity and Reliability of a Handheld Dynamometer in Measuring Isometric Shoulder Rotational Strength.

Authors:  Bin Chen; Lifen Liu; Lincoln Bin Chen; Xianxin Cao; Peng Han; Chenhao Wang; Qi Qi
Journal:  J Sport Rehabil       Date:  2021-01-19       Impact factor: 1.931

7.  Intrasession and Intersession Reliability of Isometric Trunk and Hip Strength Measurements Using the Portable Tension Dynamometer.

Authors:  Sakiko Oyama; Edgar Garza; Kylie Dugan
Journal:  J Sport Rehabil       Date:  2021-03-30       Impact factor: 1.931

Review 8.  Shoulder muscle activity and function in common shoulder rehabilitation exercises.

Authors:  Rafael F Escamilla; Kyle Yamashiro; Lonnie Paulos; James R Andrews
Journal:  Sports Med       Date:  2009       Impact factor: 11.136

9.  Validity of the Handheld Dynamometer Compared with an Isokinetic Dynamometer in Measuring Peak Hip Extension Strength.

Authors:  Heather Keep; Levana Luu; Ayli Berson; S Jayne Garland
Journal:  Physiother Can       Date:  2016       Impact factor: 1.037

10.  Absolute and relative reliability of isokinetic and isometric trunk strength testing using the IsoMed-2000 dynamometer.

Authors:  Ralf Roth; Lars Donath; Eduard Kurz; Lukas Zahner; Oliver Faude
Journal:  Phys Ther Sport       Date:  2016-11-30       Impact factor: 2.365

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.