Literature DB >> 3587148

Image intensifier distortion correction.

D P Chakraborty.   

Abstract

A method is described for determining and correcting the spatial distortion affecting images acquired with image-intensified video systems. The distortion is separated into two physically distinct components, a predominant one originating from the projection of the x-ray image onto the curved input phosphor, and a smaller component corresponding to the mapping from the input phosphor to the output phosphor and the digital image matrix. The former is determined geometrically and the latter is modeled with four empirical parameters. A method for determining the two components from calibration images of a grid phantom is presented. The model of the image intensifier distortion was found to be in good agreement with the measured distortion in the images. The correction is applicable to arbitrary angulations of the x-ray beam with respect to the image intensifier tube, and consequently is directly applicable to digital tomosynthesis. The correction allows one to obtain accurate positional information with fluorography and may also be useful in radiation therapy treatment planning and quantitative digital subtraction angiography.

Mesh:

Year:  1987        PMID: 3587148     DOI: 10.1118/1.596078

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  14 in total

Review 1.  Biplane X-ray angiograms, intravascular ultrasound, and 3D visualization of coronary vessels.

Authors:  K R Hoffmann; A Wahle; C Pellot-Barakat; J Sklansky; M Sonka
Journal:  Int J Card Imaging       Date:  1999-12

2.  A practical global distortion correction method for an image intensifier based x-ray fluoroscopy system.

Authors:  Luis F Gutiérrez; Cengizhan Ozturk; Elliot R McVeigh; Robert J Lederman
Journal:  Med Phys       Date:  2008-03       Impact factor: 4.071

3.  Image processing in digital radiography: basic concepts and applications.

Authors:  G T Barnes; K Lauro
Journal:  J Digit Imaging       Date:  1989-08       Impact factor: 4.056

4.  In-vivo validation of videodensitometric coronary cross-sectional area measurement using dual-energy digital subtraction angiography.

Authors:  S Molloi; A Ersahin; J Hicks; J Wallis
Journal:  Int J Card Imaging       Date:  1995-12

Review 5.  Macrophages in dermatology: pathogenic roles and targeted therapeutics.

Authors:  Drew Kuraitis; Nadia Rosenthal; Erin Boh; Elizabeth McBurney
Journal:  Arch Dermatol Res       Date:  2021-02-28       Impact factor: 3.017

6.  Hierarchical radial basis function networks and local polynomial un-warping for X-ray image intensifier distortion correction: a comparison with global techniques.

Authors:  P Cerveri; C Forlani; A Pedotti; G Ferrigno
Journal:  Med Biol Eng Comput       Date:  2003-03       Impact factor: 3.079

7.  Low dose x-ray sources and high quantum efficiency sensors: the next challenge in dental digital imaging?

Authors:  Arnav R Mistry; Daniel Uzbelger Feldman; Jie Yang; Eric Ryterski
Journal:  Radiol Res Pract       Date:  2014-12-10

8.  Multimodality calibration for simultaneous fluoroscopic and nuclear imaging.

Authors:  Casper Beijst; Mattijs Elschot; Sandra van der Velden; Hugo W A M de Jong
Journal:  EJNMMI Phys       Date:  2016-08-30

9.  Image intensifier distortion correction for fluoroscopic RSA: the need for independent accuracy assessment.

Authors:  Angela E Kedgley; Anne-Marie V Fox; Thomas R Jenkyn
Journal:  J Appl Clin Med Phys       Date:  2012-01-05       Impact factor: 2.102

10.  ITLN1 inhibits tumor neovascularization and myeloid derived suppressor cells accumulation in colorectal carcinoma.

Authors:  Li Chen; Xiao-Han Jin; Jie Luo; Jin-Ling Duan; Mu-Yan Cai; Jie-Wei Chen; Zi-Hao Feng; Austin Meng Guo; Feng-Wei Wang; Dan Xie
Journal:  Oncogene       Date:  2021-08-06       Impact factor: 9.867

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.