Literature DB >> 3586870

Sampling time effects on signal-to-noise and contrast-to-noise ratios in spin-echo MRI.

R E Hendrick.   

Abstract

This work discusses the effect of sampling time on noise, signal-to-noise and contrast-to-noise ratios in magnetic resonance imaging. A simple imaging experiment is performed to demonstrate the effect of sampling time on noise, confirming theoretical expectations that doubling the sampling time while decreasing the read gradient strength by a factor of two reduces statistical noise to 1/square root 2 of its original level. This result suggests that sampling time should be maximized within the constraints of the pulse sequence: namely, that sampling time should be increased and read gradient strength decreased as TE is increased. Revised expressions for signal-to-noise and contrast-to-noise ratios are presented based on the assumption that sampling time increases linearly with echo delay time above a certain minimum TE value. The revised expressions are then used to derive new predictions of the interpulse delay times that maximize signal-to-noise and contrast-to-noise ratios in spin-echo imaging. It is demonstrated that sampling times are critical in determining whether T1-weighted or T2-weighted sequences produce superior tissue contrast in spin-echo imaging.

Mesh:

Year:  1987        PMID: 3586870     DOI: 10.1016/0730-725x(87)90481-4

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  4 in total

1.  Successful treatment with stent angioplasty for Budd-Chiari syndrome in Behçet's disease.

Authors:  Seung Woo Han; Gun Woo Kim; Jongmin Lee; Yong Joo Kim; Young Mo Kang
Journal:  Rheumatol Int       Date:  2004-08-12       Impact factor: 2.631

2.  MR T1 and T2 relaxations in cysts and abscesses measured by 1.5 T MRI.

Authors:  U N Yilmaz; F Yaman; S S Atilgan
Journal:  Dentomaxillofac Radiol       Date:  2012-07       Impact factor: 2.419

3.  Optimization of survey protocols for MRI.

Authors:  E R McVeigh; R M Henkelman; M J Bronskill
Journal:  Magn Reson Med       Date:  1990-02       Impact factor: 4.668

4.  A Hyperfluorinated Hydrophilic Molecule for Aqueous 19F MRI Contrast Media.

Authors:  Eric A Tanifum; Laxman Devkota; Conelius Ngwa; Andrew A Badachhape; Ketan B Ghaghada; Jonathan Romero; Robia G Pautler; Ananth V Annapragada
Journal:  Contrast Media Mol Imaging       Date:  2018-11-12       Impact factor: 3.161

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.