| Literature DB >> 35866789 |
Huaying Yan1, Qiujun Zhou2, Haijia Zhu3, Huifeng Yang2, Hui Wang2, Jie Ling2, Jinhui Wang4, Yi Cao5, Maocan Tao5.
Abstract
BACKGROUND: The impact of Tuina on neonatal jaundice is not yet comprehensively understood, and its clinical application is rather limited. This study systematically assessed the relevant literature and conducted a meta-analysis to study the influence of Tuina on neonatal jaundice and provide convincing clinical evidence for promoting its clinical application.Entities:
Mesh:
Year: 2022 PMID: 35866789 PMCID: PMC9302356 DOI: 10.1097/MD.0000000000029675
Source DB: PubMed Journal: Medicine (Baltimore) ISSN: 0025-7974 Impact factor: 1.817
Figure 1.Flow diagram for selection of studies. RCT = randomized controlled trial.
Baseline characteristics of the included studies.
| Author | Year | Research type | Country | Number of cases | Gender (Male/Female) | Age (d) | Gestational age (week) | Weight (kg) | Measure | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Intervention group | Control group | Intervention group | Control group | Intervention group | Control group | Intervention group | Control group | Intervention group | Control group | Intervention group | Control group | ||||
| Tang et al[ | 2020 | RCT | China | 34 | 34 | 19/15 | 18/16 | – | – | 38.22 ± 2.08 | 38.14 ± 2.16 | – | – | Tuina and blue light | Blue light |
| Wang et al[ | 2018 | RCT | China | 40 | 40 | – | – | – | – | 38.61 ± 2.05 | 35.56 ± 2.12 | – | – | Tuina and blue light | Blue light |
| Peng et al[ | 2018 | RCT | China | 40 | 40 | 19/21 | 22/18 | 8.6 ± 2.9 | 8.8 ± 2.5 | – | – | – | – | Tuina and blue light | Blue light |
| Yu et al[ | 2019 | RCT | China | 34 | 33 | 17/17 | 15/18 | 12.15 ± 5.98 | 11.06 ± 5.36 | 38.15 ± 1.35 | 38.21 ± 1.45 | – | – | Tuina and blue light | Blue light |
| Ma et al[ | 2014 | RCT | China | 55 | 52 | 34/21 | 29/23 | 21.31 ± 2.94 | 19.92 ± 3.01 | – | – | – | – | Tuina and blue light | Blue light |
| Wu et al[ | 2021 | RCT | China | 75 | 75 | 36/39 | 33/42 | 27.18 ± 10.36 | 26.87 ± 10.34 | 37.52 ± 12.38 | 38.05 ± 12.41 | 3.58 ± 1.02 | 3.66 ± 1.07 | Tuina and blue light | Blue light |
| Xu et al[ | 2019 | RCT | China | 75 | 75 | 39/36 | 40/35 | 7.52 ± 2.11 | 7.49 ± 2.06 | 39.42 ± 0.27 | 39.37 ± 0.25 | 3.16 ± 0.25 | 3.19 ± 0.21 | Tuina and blue light | Blue light |
| Wang et al[ | 2016 | RCT | China | 41 | 39 | 23/18 | 26/13 | – | – | – | – | 3.24 ± 0.38 | 3.22 ± 0.35 | Tuina and blue light | Blue light |
| Aimeti et al[ | 2017 | RCT | China | 43 | 43 | 46/40 | 14.5 ± 2.7 | 38.4 ± 2.5 | 4.8 ± 2.3 | Tuina and blue light | Blue light | ||||
| Ma et al[ | 2020 | RCT | China | 33 | 33 | 18/15 | 19/14 | – | – | 38.74 ± 2.01 | 38.64 ± 2.31 | – | – | Tuina and blue light | Blue light |
| Wang et al[ | 2018 | RCT | China | 75 | 75 | 42/33 | 40/35 | – | – | 38.6 ± 3.8 | 38.7 ± 4.2 | 3.02 ± 0.033 | 3.02 ± 0.033 | Tuina and blue light | Blue light |
| Chen et al[ | 2011 | RCT | Japan | 29 | 40 | 13/14 | 15/25 | – | – | 39.76 ± 1.13 | 39.66 ± 1.0 | 3.19 ± 0.21 | 3.16 ± 0.20 | Tuina and blue light | Blue light |
| Eghbalian et al[ | 2017 | RCT | Iran | 67 | 67 | 37/30 | 29/38 | – | – | 38.61 ± 1.27 | 38.89 ± 1.6 | 3.04 ± 0.19 | 3.07 ± 0.19 | Tuina and blue light | Blue light |
RCT = randomized controlled trial.
Figure 2.Risk of bias graph.
Figure 3.Risk of bias summary.
Figure 4.Total effective rate of Tuina on newborn infants with jaundice. CI = confidence interval; RR = ratio rate.
Figure 5.TCM Syndrome Score of Chinese Tuina on newborn infants with jaundice. CI = confidence interval; WMD = weighted mean difference.
Figure 6.Serum total bilirubin of Tuina on newborn infants with jaundice. CI = confidence interval; WMD = weighted mean difference.
Figure 7.The duration of jaundice of Tuina on newborn infants with jaundice. CI = confidence interval; WMD = weighted mean difference.
Figure 8.Defecation frequency of Tuina on newborn infants with jaundice. CI = confidence interval; WMD = weighted mean difference.
Figure 9.Adverse events of Tuina on newborn infants with jaundice. CI = confidence interval; RR = ratio rate.
Figure 10.Funnel plot for assessing publication bias. RR = ratio rate.