Morphometric analysis of the lateral column of the distal humerus with an interest on radio-capitellar arthroplasty design. A computed tomography anatomical study on 50 elbows.

Giuseppe Giannicola1, Matteo Cantore2, Sebastien Prigent2, Gianluca Cinotti2, Pasquale Sessa3.   

Abstract

PURPOSE: To perform a morphometric analysis of the distal humerus lateral column medullary canal (LCMC).
METHODS: Fifty computed tomography(CTs) from 24 males and 26 females were examined. Two observers measured: (1) the capitellum sagittal (RS) and axial (RT) radii of curvature; (2) the sagittal(Sd) and coronal(Cd) diameters of the LCMC in 5 different disto-proximal sites spaced 4 mm apart; (3) the capitellum and LCMC axis offsets on the sagittal (capSO,axSO) and coronal (capCO,axCO) planes; (4) the sagittal (Si) and coronal (Ci) inclination of the LCMC axis.
RESULTS: The mean RS and RT were 1.07 cm (SD, 0.11) and 1.30 cm (SD, 0.11), respectively. The mean Sd and Cd values were 1.17 cm (SD, 0.17) and 1.58 cm (SD, 0.24), respectively, with a disto-proximal decrease on both planes. The capSO, capCO, axSO and axCO mean values were 0.76 (SD, 0.21), 1.60 (SD, 0.27), - 0.16 (SD, 0.30) and 0.79 cm (SD, 0.30), respectively. Si and Ci were 70° and 72°, respectively. A strong correlation (r = 0.78) was found between RS and RT and between adjacent levels of Sd and Cd. AxSO and axCO yielded a strong inverse correlation. Male patients showed higher values than female ones in all variables (p < 0.03). The intra-class correlation coefficient (ICC) was always > 0.9.
CONCLUSION: The dimensions of the LCMC decrease disto-proximally, with the coronal diameters being greater than the sagittal diameters, resembling a portion of an elliptic torus with an antero-medial concavity. The articular surface of the humeral capitellum is non-spherical, with two strongly correlated radii of curvature. The results of this study may be relevant to the stem design of radiocapitellar arthroplasty.
© 2022. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany.

Entities:  

Keywords:  Capitellum morphometry; Distal humerus; Elbow CT anatomy; Elbow arthroplasty; Humeral lateral column anatomy; Radiocapitellar arthroplasty

Year:  2022        PMID: 35851405     DOI: 10.1007/s00068-022-02053-3

Source DB:  PubMed          Journal:  Eur J Trauma Emerg Surg        ISSN: 1863-9933            Impact factor:   2.374


  22 in total

1.  An anthropometric study of the radial head: implications in the design of a prosthesis.

Authors:  G J King; Z D Zarzour; S D Patterson; J A Johnson
Journal:  J Arthroplasty       Date:  2001-01       Impact factor: 4.757

2.  The noncircular shape of the radial head.

Authors:  Roger P van Riet; Francis Van Glabbeek; Patricia G Neale; Hilde Bortier; Kai Nan An; Shawn W O'Driscoll
Journal:  J Hand Surg Am       Date:  2003-11       Impact factor: 2.230

3.  Morphologic analysis of the distal humerus with special interest in elbow implant sizing and alignment.

Authors:  James R Brownhill; Graham J W King; James A Johnson
Journal:  J Shoulder Elbow Surg       Date:  2007-04-06       Impact factor: 3.019

4.  A morphological analysis of the humeral capitellum with an interest in prosthesis design.

Authors:  Marlis T Sabo; Colin P McDonald; Jennifer Ng; Louis M Ferreira; Jim A Johnson; Graham J W King
Journal:  J Shoulder Elbow Surg       Date:  2011-03-30       Impact factor: 3.019

5.  An anthropometric study of the distal humerus.

Authors:  Sagar J Desai; Simon Deluce; James A Johnson; Louis M Ferreira; Alexandre E Leclerc; George S Athwal; Graham J W King
Journal:  J Shoulder Elbow Surg       Date:  2014-02-20       Impact factor: 3.019

6.  Geometry of the humeroulnar joint.

Authors:  R Shiba; C Sorbie; D W Siu; J T Bryant; T D Cooke; H W Wevers
Journal:  J Orthop Res       Date:  1988       Impact factor: 3.494

7.  Cartilage thickness of distal humerus and its relationships with bone dimensions: magnetic resonance imaging bilateral study in healthy elbows.

Authors:  Giuseppe Giannicola; Paolo Spinello; Marco Scacchi; Stefano Gumina
Journal:  J Shoulder Elbow Surg       Date:  2017-01-25       Impact factor: 3.019

8.  Anatomical variations of the trochlear notch angle: MRI analysis of 78 elbows.

Authors:  G Giannicola; M Scacchi; P Sedati; S Gumina
Journal:  Musculoskelet Surg       Date:  2016-11-30

9.  Contribution of cartilage to size and shape of radial head circumference: magnetic resonance imaging analysis of 78 elbows.

Authors:  Giuseppe Giannicola; Pietro Sedati; David Polimanti; Gianluca Cinotti; Gianluca Bullitta
Journal:  J Shoulder Elbow Surg       Date:  2015-09-26       Impact factor: 3.019

10.  The ulnar greater sigmoid notch "coverage angle": bone and cartilage contribution. Magnetic resonance imaging anatomic study on 78 elbows.

Authors:  Giuseppe Giannicola; Pietro Sedati; Gianluca Cinotti; Gianluca Bullitta; David Polimanti
Journal:  J Shoulder Elbow Surg       Date:  2015-08-01       Impact factor: 3.019