Cartilage thickness of distal humerus and its relationships with bone dimensions: magnetic resonance imaging bilateral study in healthy elbows.

Giuseppe Giannicola1, Paolo Spinello2, Marco Scacchi2, Stefano Gumina2.   

Abstract

BACKGROUND: Little is known about the cartilage thickness of the distal humerus and how it affects the shape of the articular surface. Our aims were to assess cartilage thickness and to determine the extent to which it affects the true profile of the distal humerus.
METHODS: We assessed 78 healthy elbows (39 subjects, 19 women and 20 men) with a mean age of 28 years (range, 21-32 years). Cartilage thickness was measured by use of high-definition magnetic resonance imaging scans at 19 different points of the articular surface, 13 on the trochlea and 6 on the capitellum, on the axial and coronal views. Bone diameters at the medial and lateral trochlear ridges, trochlear groove, and capitellum, as well as the articular surface width, were measured. Subject height was used as an indirect measurement of humerus length. Pearson correlation coefficients and the Student t test were used.
RESULTS: Cartilage thickness showed a significant variation (range, 0.4-1.8 mm) independent of sex and side. It appeared thinner at the medial and lateral edges, whereas it increased at the level of the trochleocapitellar and trochlear grooves, the lateral trochlear ridges, and the center of the capitellum. The mean bone diameters of the medial ridge, lateral ridge, trochlear groove, and capitellum measured 25.1 mm, 21 mm, 16.9 mm, and 19.6 mm, respectively. The mean width of the articular surface was 42.9 mm (range, 35.8-50.2 mm). No significant correlation was found between cartilage thickness and bone dimensions.
CONCLUSION: Cartilage thickness is not uniform and modifies the morphologic shape and diameters of the humeral articular surface. These findings may be relevant to anatomic prosthesis design.
Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Cartilage; capitellum; elbow; hemiarthroplasty; humeral trochlea; humerus; thickness; ulnohumeral joint

Mesh:

Year:  2017        PMID: 28131685     DOI: 10.1016/j.jse.2016.10.012

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  5 in total

1.  Morphometric analysis of the lateral column of the distal humerus with an interest on radio-capitellar arthroplasty design. A computed tomography anatomical study on 50 elbows.

Authors:  Giuseppe Giannicola; Matteo Cantore; Sebastien Prigent; Gianluca Cinotti; Pasquale Sessa
Journal:  Eur J Trauma Emerg Surg       Date:  2022-07-18       Impact factor: 2.374

2.  Distal Humeral Trochlear Geometry Associated With the Spatial Variation of the Dynamic Elbow Flexion Axis.

Authors:  Diyang Zou; Xiangjun Hu; Kai-Nan An; Kerong Dai; Xiaowei Yu; Weihua Gong; Tsung-Yuan Tsai
Journal:  Front Bioeng Biotechnol       Date:  2022-06-24

3.  A Comprehensive Coronal and Axial Bone Dimension and Cartilage Thickness Evaluation of the Distal Humerus: Age and Sex Differences.

Authors:  Abdulhamit Misir; Ali Eray Gunay; Sinan Oguzkaya; Erdal Uzun; Turan Bilge Kizkapan; Kadir Ilker Yildiz; Mustafa Ozcamdalli
Journal:  Cartilage       Date:  2020-02-10       Impact factor: 3.117

4.  Regional Distribution of Articular Cartilage Thickness in the Elbow Joint: A 3-Dimensional Study in Elderly Humans.

Authors:  Satoshi Miyamura; Takashi Sakai; Kunihiro Oka; Shingo Abe; Atsuo Shigi; Hiroyuki Tanaka; Shoichi Shimada; Tatsuo Mae; Kazuomi Sugamoto; Hideki Yoshikawa; Tsuyoshi Murase
Journal:  JB JS Open Access       Date:  2019-07-31

5.  Novel exploration of 3D printed personalized total elbow arthroplasty to solve the severe bone defect after internal fixation failure of comminuted distal humerus fracture: A case report.

Authors:  Naichao Wu; Shan Li; Yang Liu; Aobo Zhang; Bingpeng Chen; Qing Han; Jincheng Wang
Journal:  Medicine (Baltimore)       Date:  2020-07-31       Impact factor: 1.817