Aurore Bousquet1, Sébastien Larréché2, Christine Bigaillon2, Alexandre Woloch3, Léa Thomas3, Pierre Louis Conan4, Audrey Mérens2.
Abstract
We compared ID Now™ and Hologic® Panther Aptima™ for the detection of SARS-COV-2. ID Now™ showed a positive and negative percent agreement of 86.9% and 99.7% respectively. This facilitates faster clinical decision-making, along with the rapid implementation of infection control measures, and improvement of patient flow in the emergency department toward inpatient wards.Entities:
Keywords: COVID-19; Hologic Panther Point of care device; ID NOW; SARS-CoV-2
Mesh:
Year: 2022 PMID: 35843113 PMCID: PMC9188679 DOI: 10.1016/j.diagmicrobio.2022.115742
Source DB: PubMed Journal: Diagn Microbiol Infect Dis ISSN: 0732-8893 Impact factor: 2.983
Comparison of Abbott® ID now™ to Hologic® Panther Aptima™.
| ABBOTT® ID now™ results | ||||
|---|---|---|---|---|
| Positive | Negative | Total | ||
| Hologic® Panther Aptima™ results | Positive | 126 | 19 | 145 |
| Negative | 10 | 3781 | 3791 | |
| Total | 136 | 3800 | 3936 | |
| Performances | Positive predictive value | 92.6% | Positive percent agreement | 86.9% (95% CI 81.4, 92.4) |
| Negative predictive value | 99.5% | Negative percent agreement | 99.7% (95% CI 99.6, 99.9) | |