| Literature DB >> 35816260 |
Mario Sansone1, Stefano Marrone2, Giusi Di Salvio2, Maria Paola Belfiore3, Gianluca Gatta3, Roberta Fusco4, Laura Vanore3, Chiara Zuiani5, Francesca Grassi3, Maria Teresa Vietri6, Vincenza Granata7, Roberto Grassi3,8.
Abstract
BACKGROUND: Pectoral muscle removal is a fundamental preliminary step in computer-aided diagnosis systems for full-field digital mammography (FFDM). Currently, two open-source publicly available packages (LIBRA and OpenBreast) provide algorithms for pectoral muscle removal within Matlab environment.Entities:
Keywords: Breast evaluation; Full-field digital mammography; Pectoral muscle removal
Mesh:
Year: 2022 PMID: 35816260 PMCID: PMC9349098 DOI: 10.1007/s11547-022-01521-5
Source DB: PubMed Journal: Radiol Med ISSN: 0033-8362 Impact factor: 6.313
Patients characteristics: number of patients across breast density and age group
| Age group (yrs) | Breast density | ||||
|---|---|---|---|---|---|
| A | B | C | D | Sum | |
| 15–44 | 0 | 6 | 2 | 7 | 15 |
| 45–54 | 4 | 18 | 25 | 9 | 56 |
| 55–64 | 8 | 41 | 5 | 15 | 69 |
| 65–78 | 5 | 14 | 0 | 5 | 24 |
| > 78 | 0 | 3 | 1 | 0 | 4 |
| Sum | 17 | 82 | 33 | 36 | 168 |
Image and equipment characteristics
| Anode material | Tungsten (W) |
|---|---|
| Filter materials | 0.05 mm silver (Ag); a 0.7 mm aluminum (Al) filter may be also available on the system |
| Detector | a-Se Flat Panel Detector |
| Pixel size [µm] | 85 |
| kVp | 31 (26–35) |
| Exposure time [ms] | 508 (106–1340) |
| mAs | 75.35 (14.91–200.22) |
| Anode/filter combination | W/Ag |
| Entrance dose [mGy] | 4.77 (0.87–17.31) |
Fig. 1Illustrative examples of pectoral muscle delineation. Manual (red), LIBRA (green) and OpenBreast (yellow). Breast parenchyma contour is also reported for comparison. Breast density is indicated below each image
Fig. 2a Dice-index of LIBRA and OpenBreast versus gold truth has been reported per each combination of breast density (A,B,C,D) and laterality (left, right); each subject is identified by a colored circle, and the measurements on the same subject but with different packages are connected by lines. b Cohen’s kappa of LIBRA and OpenBreast versus gold truth has been reported per each combination of breast density (A,B,C,D) and laterality (left, right); each subject is identified by a colored circle, and the measurements on the same subject but with different packages are connected by lines
Average Dice-index, Cohen’s kappa, TP, TN, FP, FN fractions have been reported per each package/breast density
| OpenBreast | LIBRA | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Breast density | TP | FP | FN | TN | Dice | kappa | TP | FP | FN | TN | Dice | kappa |
| A | 0.27 | 0.01 | 0.02 | 0.70 | 0.94 | 0.92 | 0.28 | 0.02 | 0.01 | 0.69 | 0.95 | 0.93 |
| B | 0.25 | 0.01 | 0.02 | 0.72 | 0.94 | 0.92 | 0.26 | 0.01 | 0.01 | 0.72 | 0.96 | 0.95 |
| C | 0.22 | 0.02 | 0.01 | 0.76 | 0.94 | 0.93 | 0.22 | 0.01 | 0.01 | 0.76 | 0.96 | 0.95 |
| D | 0.24 | 0.02 | 0.01 | 0.73 | 0.94 | 0.92 | 0.24 | 0.01 | 0.01 | 0.74 | 0.96 | 0.95 |