INTRODUCTION: Guidelines recommend lifelong follow-up with transthoracic echocardiograms (TTE) for patients who had a patent ductus arteriosus (PDA) device closure via catheterization. The goal of this study was to determine the utility of follow-up TTE in patients who underwent an uncomplicated PDA device closure after infancy.Entities:
Keywords: Echocardiogram; Patent ductus arteriosus; Transthoracic echocardiogram
Year: 2022 PMID: 35780440 PMCID: PMC9381662 DOI: 10.1007/s40119-022-00272-8
Source DB: PubMed Journal: Cardiol Ther ISSN: 2193-6544
PDA device data
| Device ( | % | |
|---|---|---|
| Amplatzer Duct Occludera | 68 | 36.0 |
| Amplatzer Duct Occluder IIa | 6 | 3.2 |
| Amplatzer Duct Occluder II AS/Piccoloa | 2 | 1.1 |
| Amplatzer Vascular Pluga | 10 | 5.3 |
| Amplatzer Vascular Plug IIa | 13 | 6.9 |
| Amplatzer muscular ventricular septal defecta | 2 | 1.1 |
| Nit Occludb | 63 | 33.3 |
| Flipper Detachable Embolization Coilc | 25 | 13.2 |
PDA patent ductus arteriosus
aAbbott Cardiovascular
bPlymouth, MN, USA; B Braun Interventional Systems, Bethlehem, PA, USA
cCook Medical, Bloomington, IN, USA
Initial echocardiographic changes
| Initial echocardiogram ( | Follow-up echocardiogram ( | |
|---|---|---|
| DAo velocity (m/s) | 1.22 ± 0.33 | 1.23 ± 0.27 |
| LPA velocity (m/s) | 1.14 ± 0.39* | 1.07 ± 0.29* |
| Shortening fraction (%) | 36.51 ± 5.03 | 37.17 + 4.85 |
| LVIDD | 0.88 ± 1.58* 0.64 (− 2.44 to 6.59) | 0.03 ± 1.14* 0.03 (− 3.29 to 3.09) |
DAo descending aorta, LPA left pulmonary artery, LVIDD left ventricular internal diastolic dimension
*Significant difference (p < 0.05)
Final echocardiographic changes
| Initial echocardiogram ( | Most recent echocardiogram ( | |
|---|---|---|
| DAo velocity (m/s) | 1.20 ± 0.32* | 1.28 ± 0.28* |
| LPA velocity (m/s) | 1.14 ± 0.40 | 1.12 ± 0.35 |
| Shortening fraction (%) | 36.42 ± 5.03 | 36.94 ± 5.58 |
| LVIDD | 1.36 ± 1.77* 1.14 (− 2.31 to 6.59) | − 0.05 ± 1.16* − 0.03 (− 4.20 to 2.42) |
DAo descending aorta, LPA left pulmonary artery, LVIDD left ventricular internal diastolic dimension
*Significant difference
Fig. 1Velocity changes over time in the left pulmonary artery and descending aorta
| Guidelines recommend intermittent lifelong echocardiograms in patients who underwent a transcatheter patent ductus arteriosus (PDA) device closure. |
| In this study, no significant complications were noted in patients that had an uncomplicated PDA device closure with follow-up echocardiograms. |
| The need for routine lifelong echocardiograms in this population should be further evaluated to determine the cost-effectiveness of this recommendation. |