Literature DB >> 32339400

Incidence and fate of device-related left pulmonary artery stenosis and aortic coarctation in small infants undergoing transcatheter patent ductus arteriosus closure.

Catherine E Tomasulo1, Matthew J Gillespie1, David Munson2, Taylor Demkin1, Michael L O'Byrne1,3, Yoav Dori1, Christopher L Smith1, Jonathan J Rome1, Andrew C Glatz1,3.   

Abstract

OBJECTIVES: To evaluate short- and middle-term outcomes after transcatheter patent ductus arteriosus (TC-PDA) closure in small infants, specifically device-related left pulmonary artery (LPA) stenosis and aortic coarctation, risk factors, and changes over time.
BACKGROUND: Recent studies have demonstrated successful transcatheter PDA (TC-PDA) closure in small infants. LPA stenosis and aortic coarctation have been seen after TC-PDA, but it is not clear whether device-related LPA/aortic obstruction persists.
METHODS: A single-center retrospective study of infants ≤4 kg who underwent TC-PDA closure from February 1, 2007 to September 1, 2018 was performed, evaluating the incidence and risk factors for LPA stenosis and coarctation.
RESULTS: Forty-four patients underwent successful TC-PDA with Amplatzer Vascular Plug II (AVPII; n = 30), Amplatzer Duct Occluder II-Additional Sizes (n = 10), Amplatzer Duct Occluder I (n = 3), and coil-filled AVPI (n = 1) devices, all via an antegrade approach. Median birthweight and procedural weight were 890 g (range: 490-3,250) and 2.8 kg (range: 1.2-4.0), respectively. Median follow-up was 0.7 years (range: 2 days-7 years). Thirty-eight patients had post-procedure echocardiograms assessing LPA/aortic obstruction. Of those, 17 had LPA flow acceleration/stenosis (≥1.5 m/s), which improved or resolved in all patients with available follow-up; 3 developed mild coarctation (>2 m/s), which improved in the two with more than short-term follow-up; 4 developed mild flow acceleration (1.5-2 m/s) in the descending aorta, which resolved in three and increased in one (2.4 m/s). Flow acceleration in the LPA was associated with younger procedural age, larger PDA minimal diameter, and placement of a device other than the AVPII. There was no device-related mortality or need for reintervention.
CONCLUSION: TC-PDA in small infants is effective, without significant complications. Device-related LPA/aortic obstruction can improve with time/growth.
© 2020 Wiley Periodicals, Inc.

Entities:  

Keywords:  catheterization; congenital heart disease; percutaneous; premature

Mesh:

Year:  2020        PMID: 32339400     DOI: 10.1002/ccd.28942

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  6 in total

1.  Fate of the Left Pulmonary Artery and Thoracic Aorta After Transcatheter Patent Ductus Arteriosus Closure in Low Birth Weight Premature Infants.

Authors:  Dor Markush; Jennifer C Tsing; Surbhi Gupta; Nicole C Berndsen; Geena Radville; Ruchira Garg; Evan M Zahn; Myriam Almeida-Jones
Journal:  Pediatr Cardiol       Date:  2021-01-04       Impact factor: 1.655

2.  Transvenous embolization of moderate to large patent ductus arteriosus in dogs using the Amplatzer vascular plug II.

Authors:  Nicolai Hildebrandt; Andreas Stosic; Estelle Henrich; Nicola Wiedemann; Gabriel Wurtinger; Matthias Schneider
Journal:  J Vet Intern Med       Date:  2021-12-16       Impact factor: 3.333

3.  Transcatheter Closure of a Patent Ductus Arteriosus Using a Piccolo Duct Occluder.

Authors:  Pranjit Deb; Anindya Benerjee; Tapas Som; Ramachandra Barik
Journal:  Cureus       Date:  2022-08-21

4.  Utility of Follow-Up Echocardiograms in Uncomplicated PDA Device Closures Performed After Infancy.

Authors:  Rachel Reo; Erin Van Pelt; Casey Lovelace; Anne Eshelman; Brian Beckman; Joanne Chisolm; Brian Boe; Carl Backes; Clifford L Cua
Journal:  Cardiol Ther       Date:  2022-07-03

Review 5.  Consensus Guidelines for the Prevention and Management of Periprocedural Complications of Transcatheter Patent Ductus Arteriosus Closure with the Amplatzer Piccolo Occluder in Extremely Low Birth Weight Infants.

Authors:  Shyam Sathanandam; Dan Gutfinger; Brian Morray; Darren Berman; Matthew Gillespie; Thomas Forbes; Jason N Johnson; Ruchira Garg; Sophie Malekzadeh-Milani; Alain Fraisse; Osman Baspinar; Evan M Zahn
Journal:  Pediatr Cardiol       Date:  2021-06-30       Impact factor: 1.655

6.  Low profile vascular plug for transarterial occlusion of patent ductus arteriosus in small dogs.

Authors:  Alma H Hulsman; Johannes M P J Breur; Viktor Szatmári
Journal:  J Vet Intern Med       Date:  2020-11-26       Impact factor: 3.175

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.