Effect of emergency department procedural sedation on noninvasively measured haemodynamic variables
| Haemodynamic variable | Baseline | T = 2 | T = 3 | T = 5 |
|
|---|---|---|---|---|---|
| CI (l/min/m2) | 3.1 (2.4–3.5) | 3.0 (2.5–3.7) | 3.0 (2.4–3.6) | 3.0 (2.3–3.5) | 0.86 |
| SV (ml) | 75 (62–105) | 73 (55–99)[ | 75 (59–104) | 76 (59–100) | 0.02 |
| SVR (dyn/s/cm−5) | 1324 (985–1917) | 1212 (838–1580)[ | 1239 (874–1696)[ | 1177 (894–1408)[ | <0.001 |
| SBP (mmHg) | 147 (134–164) | 132 (117–168)[ | 135 (114–160)[ | 132 (113–154)[ | <0.001 |
| HR (bpm) | 74 (64–90) | 79 (71–96)[ | 77 (67–94) | 75 (67–92)[ | 0.002 |
Data presented as median (IQR).
CI, cardiac index; HR, heart rate; IQR, interquartile range; SV, stroke volume; SVR, systemic vascular resistance.
Denotes a significant difference after Bonferroni correction in post hoc testing compared to baseline measurements pre-PSA. T2, T3 and T5 represent measurements 2, 3 and 5 min after administration of medication respectively.