Literature DB >> 35771482

Intraoperative joint balancing procedure using an imageless robotic assisted technique does not necessarily result in kinematically aligned bicruciate stabilized total knee arthroplasty.

Takao Kaneko1, Ayakane Yamamoto2, Kazutaka Takada2, Shu Yoshizawa2.   

Abstract

The primary aim of this study was to retrospectively evaluate the hip- knee- ankle. (HKA) angle and prosthetic alignment with three-dimensional computed tomography (3DCT) measurements in patients who underwent robotic-assisted (RA) TKA, with consideration of the soft tissue envelope via an intraoperative joint-balancing procedure. We hypothesized that intraoperative consideration of soft tissue laxity in individual patients using imageless RA technology will not necessarily result in kinematically aligned bicruciate stabilized total knee arthroplasty (KA TKA). This retrospective study included consecutive patients who underwent RA TKA between 2019 and 2020. The indication for TKA was varus osteoarthritis of the knee. During this period, 60 RA bi-cruciate stabilized TKAs were performed. Prosthetic alignments were measured using computer software with 3DCT. We determined prosthetic positioning and bone resection volume with consideration of the soft tissue envelope using an intraoperative full range of motion joint-balancing procedure during RA TKA. 3DCT scans of the entire lower extremity were taken before and after surgery. Postoperative varus HKA alignment occurred in 58% of patients who underwent RA TKA, 31% of knees were in femoral valgus alignment and tibial varus alignment, and 42% had femoral components in internal rotation among knees with femoral valgus alignment and tibial varus alignment. The mean thickness of the osteotomized medial and lateral posterior condyles of the femur were 11.2 and 9.1 mm, respectively, based on 3DCT measurements. Intraoperative consideration of soft tissue laxity in individual patientsusing an imageless RA technique does not necessarily result in KA bicruciate TKA.
© 2022. The Author(s), under exclusive licence to Springer-Verlag London Ltd., part of Springer Nature.

Entities:  

Keywords:  Kinematically aligned total knee arthroplasty; Robotic assisted total knee arthroplasty; Soft tissue envelope; Three-dimensional computed tomography

Year:  2022        PMID: 35771482     DOI: 10.1007/s11701-022-01429-2

Source DB:  PubMed          Journal:  J Robot Surg        ISSN: 1863-2483


  12 in total

1.  Radiological assessment of osteo-arthrosis.

Authors:  J H KELLGREN; J S LAWRENCE
Journal:  Ann Rheum Dis       Date:  1957-12       Impact factor: 19.103

Review 2.  Early Outcomes of Kinematic Alignment in Primary Total Knee Arthroplasty: A Meta-Analysis of the Literature.

Authors:  P Maxwell Courtney; Gwo-Chin Lee
Journal:  J Arthroplasty       Date:  2017-02-27       Impact factor: 4.757

3.  High degree of accuracy of a novel image-free handheld robot for unicondylar knee arthroplasty in a cadaveric study.

Authors:  Jess H Lonner; Julie R Smith; Frederic Picard; Brian Hamlin; Philip J Rowe; Philip E Riches
Journal:  Clin Orthop Relat Res       Date:  2015-01       Impact factor: 4.176

4.  Midterm Comparison of Tibial Fixation between Posterior Cruciate-Retaining and Substituting Porous Tantalum Total Knee Arthroplasty: Three-Dimensional Computed Tomography Analysis.

Authors:  Takao Kaneko; Norihiko Kono; Yuta Mochizuki; Masaru Hada; Shinya Toyoda; Hiroyasu Ikegami; Yoshiro Musha
Journal:  J Knee Surg       Date:  2019-07-09       Impact factor: 2.757

5.  Similar Risk of Revision After Kinematically Aligned, Patient-Specific Instrumented Total Knee Arthroplasty, and All Other Total Knee Arthroplasty: Combined Results From the Australian and New Zealand Joint Replacement Registries.

Authors:  Antonio Klasan; Richard de Steiger; Sherina Holland; Alesha Hatton; Christopher J Vertullo; Simon W Young
Journal:  J Arthroplasty       Date:  2020-06-01       Impact factor: 4.757

6.  Bi-cruciate substituting total knee arthroplasty improved medio-lateral instability in mid-flexion range.

Authors:  Takao Kaneko; Norihiko Kono; Yuta Mochizuki; Masaru Hada; Shinya Toyoda; Yoshiro Musha
Journal:  J Orthop       Date:  2017-01-07

7.  Combined ACL reconstruction and opening wedge high tibial osteotomy at 10-year follow-up: excellent laxity control but uncertain return to high level sport.

Authors:  A Schneider; R Gaillard; S Gunst; C Batailler; P Neyret; S Lustig; E Servien
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-07-13       Impact factor: 4.342

8.  Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients.

Authors:  Stephen M Howell; Kyle Kuznik; Maury L Hull; Robert A Siston
Journal:  Orthopedics       Date:  2008-09       Impact factor: 1.390

9.  Slight undercorrection following total knee arthroplasty results in superior clinical outcomes in varus knees.

Authors:  Luc Vanlommel; Jan Vanlommel; Steven Claes; Johan Bellemans
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-04       Impact factor: 4.342

10.  Robotic-assisted total knee arthroplasty improves the outlier of rotational alignment of the tibial prosthesis using 3DCT measurements.

Authors:  Takao Kaneko; Tadashi Igarashi; Kazutaka Takada; Shu Yoshizawa; Hiroyasu Ikegami; Yoshiro Musha
Journal:  Knee       Date:  2021-06-09       Impact factor: 2.199

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.