Midterm Comparison of Tibial Fixation between Posterior Cruciate-Retaining and Substituting Porous Tantalum Total Knee Arthroplasty: Three-Dimensional Computed Tomography Analysis.

Takao Kaneko1, Norihiko Kono1, Yuta Mochizuki1, Masaru Hada1, Shinya Toyoda1, Hiroyasu Ikegami1, Yoshiro Musha1.   

Abstract

Porous tantalum tibial component is durable with excellent bone ingrowth, higher knee scores, and long-term survivorship. However, to our knowledge, the effect of posterior cruciate-retaining (CR) and posterior cruciate-substituting (PS) porous tantalum tibial component has not been reported. The aim of the current study was to investigate the prosthetic bone quality between CR porous tantalum tibial component and PS using three-dimensional multi-detector-row computed tomography (3D-MDCT). Porous twenty-two (22) CR total knee arthroplasties and 22 PS received 3D-MDCT at every 6 months up to 5.5 years postoperatively to assess prosthetic bone quality (bone marrow contents/tissue volumes [BMC/TV, mg/cm3]) underneath the pegs of porous tantalum modular tibial component. Clinical outcomes (Knee Society score [KSS], Western Ontario and McMaster Universities (WOMAC), FJS-12, Patella score) were evaluated at a minimum follow-up period of 5.5 years. No statistically significant differences were found in age, gender, body mass index, KSS, and BMC/TV volumes in the proximal tibia between the two groups before total knee arthroplasty (TKA). There were also no significant differences between the CR and PS groups with regard to BMC/TV at every 6 months up to 5.5 years after TKA. At 5.5 years postoperatively, there was no significant difference between the two groups in terms of the KSS, WOMAC, forgotten joint score (FJS-12), and Patella score. The present study revealed that the prosthetic bone quality of the CR porous tantalum tibial component and PS were equivalent at every 6 months up to 5.5 years after TKA. This study reflects level II evidence. Thieme. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31288269     DOI: 10.1055/s-0039-1693453

Source DB:  PubMed          Journal:  J Knee Surg        ISSN: 1538-8506            Impact factor:   2.757


  2 in total

1.  Intraoperative joint balancing procedure using an imageless robotic assisted technique does not necessarily result in kinematically aligned bicruciate stabilized total knee arthroplasty.

Authors:  Takao Kaneko; Ayakane Yamamoto; Kazutaka Takada; Shu Yoshizawa
Journal:  J Robot Surg       Date:  2022-06-30

2.  Diagnostic Value Comparison between Multislice Spiral Computerized Tomography and Magnetic Resonance Imaging under Artificial Intelligence Algorithm in Diagnosing Occult Fractures of the Knee Joint.

Authors:  Zhenghua Shu; Jun Lei; Chaoqi Ding
Journal:  Contrast Media Mol Imaging       Date:  2022-09-27       Impact factor: 3.009

  2 in total