Literature DB >> 3575415

Implementation of random positioning error in computerised radiation treatment planning systems as a result of fractionation.

J Leong.   

Abstract

Fractionation is widely employed in radiation therapy. The number of fractions N can vary from 1 to more than 25. Associated with this multifraction treatment is the inability to reposition patients exactly from fraction to fraction or from patient to patient. The effect of this positioning error is analysed within the context of computerised treatment planning (dose calculation). A simple method is described in which this analysis can be easily incorporated into most computerised two-dimensional treatment planning systems. The result is a 'modified' isodose plan in which fluctuation in patient positioning from fraction to fraction is taken into account. The effect of N on dose calculation is further analysed. A procedure to express dose predictions on paper plan due to the finite value of N is described in terms of the uncertainty in dose predictions and the most probable dose predictions.

Entities:  

Mesh:

Year:  1987        PMID: 3575415     DOI: 10.1088/0031-9155/32/3/002

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

Review 1.  Adaptive radiation therapy for prostate cancer.

Authors:  Michel Ghilezan; Di Yan; Alvaro Martinez
Journal:  Semin Radiat Oncol       Date:  2010-04       Impact factor: 5.934

2.  A gradient feature weighted Minimax algorithm for registration of multiple portal images to 3DCT volumes in prostate radiotherapy.

Authors:  Sudhakar Chelikani; Kailasnath Purushothaman; Jonathan Knisely; Zhe Chen; Ravinder Nath; Ravi Bansal; James Duncan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-06-01       Impact factor: 7.038

3.  Quantifying the interplay effect in prostate IMRT delivery using a convolution-based method.

Authors:  Haisen S Li; Indrin J Chetty; Timothy D Solberg
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

4.  Comparisons of treatment optimization directly incorporating random patient setup uncertainty with a margin-based approach.

Authors:  Joseph A Moore; John J Gordon; Mitchell S Anscher; Jeffrey V Siebers
Journal:  Med Phys       Date:  2009-09       Impact factor: 4.071

5.  A systematic approach to statistical analysis in dosimetry and patient-specific IMRT plan verification measurements.

Authors:  Songbing Qin; Miao Zhang; Sung Kim; Ting Chen; Leonard H Kim; Bruce G Haffty; Ning J Yue
Journal:  Radiat Oncol       Date:  2013-09-30       Impact factor: 3.481

6.  Margin selection to compensate for loss of target dose coverage due to target motion during external-beam radiation therapy of the lung.

Authors:  W Kyle Foster; Ernest Osei; Rob Barnett
Journal:  J Appl Clin Med Phys       Date:  2015-01-08       Impact factor: 2.102

7.  Quality assurance using a photodiode array.

Authors:  M J Balderson; D P Spencer; I Nygren; D W Brown
Journal:  J Appl Clin Med Phys       Date:  2011-01-31       Impact factor: 2.102

8.  Influence of intra- and interfraction motion on planning target volume margin in liver stereotactic body radiation therapy using breath hold.

Authors:  Patricia A K Oliver; Mammo Yewondwossen; Clare Summers; Conor Shaw; Slawa Cwajna; Alasdair Syme
Journal:  Adv Radiat Oncol       Date:  2020-11-19

9.  Influence of increased target dose inhomogeneity on margins for breathing motion compensation in conformal stereotactic body radiotherapy.

Authors:  Anne Richter; Kurt Baier; Juergen Meyer; Juergen Wilbert; Thomas Krieger; Michael Flentje; Matthias Guckenberger
Journal:  BMC Med Phys       Date:  2008-12-03

10.  Retrospective analysis of the impact of respiratory motion in treatment margins for frameless lung SBRT based on respiratory-correlated CBCT data-sets.

Authors:  Sheeba Thengumpallil; Damien Racine; Jean-François Germond; Nicolas Péguret; Jean Bourhis; François Bochud; Raphaël Moeckli
Journal:  J Appl Clin Med Phys       Date:  2020-09-30       Impact factor: 2.102

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.