| Literature DB >> 35740460 |
Takahiro Kitsuka1, Rikako Hama1,2, Anudari Ulziibayar1, Yuichi Matsuzaki1, John Kelly1, Toshiharu Shinoka1,3,4.
Abstract
Cardiovascular-related medical conditions remain a significant cause of death worldwide despite the advent of tissue engineering research more than half a century ago. Although autologous tissue is still the preferred treatment, donor tissue is limited, and there remains a need for tissue-engineered vascular grafts (TEVGs). The production of extensive vascular tissue (>1 cm3) in vitro meets the clinical needs of tissue grafts and biological research applications. The use of TEVGs in human patients remains limited due to issues related to thrombogenesis and stenosis. In addition to the advancement of simple manufacturing methods, the shift of attention to the combination of synthetic polymers and bio-derived materials and cell sources has enabled synergistic combinations of vascular tissue development. This review details the selection of biomaterials, cell sources and relevant clinical trials related to large diameter vascular grafts. Finally, we will discuss the remaining challenges in the tissue engineering field resulting from complex requirements by covering both basic and clinical research from the perspective of material design.Entities:
Keywords: 3D printing; biodegradable scaffolds; clinical trials; decellularized tissue; electrospinning; silk fibroin; synthetic polymers; tissue engineering; tissue-engineered vascular grafts (TEVGs)
Year: 2022 PMID: 35740460 PMCID: PMC9220152 DOI: 10.3390/biomedicines10061439
Source DB: PubMed Journal: Biomedicines ISSN: 2227-9059
Figure 1The advantages and disadvantages of TEVGs have emerged over years of development. Recently, the focus has been on the development of next-generation TEVGs with cells and ECM in synthetic polymer-based materials. The image was produced by the authors using the photos provided by Gunze Ltd. (Tokyo, Japan).
Figure 2(a) Typical structure diagram of blood vessels. Blood vessels consist of three layers: tunica intima, tunica media, and tunica externa. (b) Tissue staining image of a typical TEVG fabricated with polylactide-co-caprolactone (PCLA) and polyglycolic acid (PGA) in sheep models. After only six weeks, TEVG has remodeled three layers like a native vessel structure. The image was produced by the authors using images from our previous study.
Studies of vascular grafts for achieving good mechanical properties and patency.
| Manufacturing Method | Component | Development Level | Comments | Refs |
|---|---|---|---|---|
| Gore-tex® | ePTFE | in vitro | Low patency; only two/seven (29%) after six months. | [ |
| electrospinning fiber | PCL | in vivo (rat model) | Patency until 18 months. | [ |
| electrospinning fiber | PU/PCL | in vitro | A dual functional polyurethane for mimics of blood vessel inner surfaces by combining surface texture and nitric oxide (NO) release. | [ |
| Mesh coated in additional polymers | P(LA/CL) and PGA or PLLA, autologous | in vivo (human trial) | First human clinical trial. | [ |
| Mesh with a coating(sponge) | Silk fibroin/ | in vivo (canine model) | Patency until one year. | [ |
| Decellularized tissue | Pig’s carotid artery | in vitro | First decellularized tissue material. | [ |
| Decellularized tissue | Human placenta, Tissues crosslinked by riboflavin-mediated UV and coating with heparin | in vivo (rat model) | Patency after four weeks without the use of anticoagulants. | [ |
| Decellularized tissue | Rat’s aorta, | in vivo (rat model) | Sustained release of the drug from the PCL nanofiber layer reduces neointimal hyperplasia. | [ |
| Decellularized tissue | Ostrich carotid | in vivo (pig model) | Long bypass graft 20–30 cm in length. | [ |
Figure 3Progressive remodeling in TEVGs in which cells were seeded on scaffold material. It was produced by the authors using the photos provided by Gunze Ltd. (Tokyo, Japan).
Figure 4This figure shows immediately after the TEVG implantation (left) and one year after the TEVG implant (right) in sheep models. As shown in the figure, one year after implanting the TEVG, it had adapted to the native blood vessel. The figure was produced by the authors using the images from our previous study.