Literature DB >> 35731717

High-Frequency Oscillatory Ventilation for Refractory Hypoxemia in Severe COVID-19 Pneumonia: A Small Case Series.

Philip Keith1, L Keith Scott2, Linda Perkins1, Rebecca Burnside1, Matthew Day1.   

Abstract

BACKGROUND COVID-19 continues to place a tremendous burden on the healthcare system, with most deaths resulting from respiratory failure. Management strategies have varied, but the mortality rate for mechanically ventilated patients remains high. Conventional management with ARDSnet ventilation can improve outcomes but alternative and adjunct treatments continue to be explored. High-frequency oscillatory ventilation (HFOV), a modality now rarely used in adult critical care medicine, may offer an alternative treatment option by maximizing lung protection and limiting oxygen toxicity in critically ill patients failing conventional ventilator strategies. CASE REPORT We present 3 patients with severe acute respiratory distress syndrome (ARDS) and sepsis due to COVID-19 who all improved clinically after transitioning from conventional ventilation to HFOV. Two patients developed refractory hypoxemia with hemodynamic instability and multiple organ failure requiring vasopressor support and renal replacement therapy. After failing to improve with all available therapies, both patients stabilized and ultimately improved after being placed on HFOV. The third patient developed severe volutrauma/barotrauma despite extreme lung protection and ARDSnet ventilation. He showed improvement in oxygenation and signs of lung trauma slowly improved after initiating HFOV. All 3 patients were ultimately liberated from mechanical ventilation and discharged from the hospital to return to functional independence. CONCLUSIONS Our experience suggests that HFOV offers advantages in the management of certain critically ill patients with ARDS due to COVID-19 pneumonia and might be considered in cases refractory to standard management strategies.

Entities:  

Mesh:

Year:  2022        PMID: 35731717      PMCID: PMC9238079          DOI: 10.12659/AJCR.936651

Source DB:  PubMed          Journal:  Am J Case Rep        ISSN: 1941-5923


Background

Two years into a global pandemic, COVID-19 continues to place a tremendous burden on the healthcare system, with critical disease most commonly presenting as respiratory failure. While management of hypoxemic patients remains somewhat inconsistent and controversial, most guidelines recommend management according to well-established ARDSnet guidelines [1]. The true pathophysiology of lung injury due to SARSCoV-2 infection remains uncertain, but lung protection from oxygen toxicity and excessive tidal volumes remain important management strategies. Prone ventilation, combined with lung protective ventilation, has proven to be clinically efficacious for acute respiratory distress syndrome (ARDS) [2] and has become routine in COVID-19-associated lung injury [3]. Despite these measures, refractory lung failure leading to death remains common. Additional therapies and treatments such as inhaled pulmonary artery vasodilators, alternative modes of ventilation such as airway pressure release ventilation (APRV), and extra-corporeal membrane oxygenation (ECMO) have been utilized throughout the pandemic. Similar to their use for ARDS prior to COVID, reported outcomes have been variable but largely disappointing, certainly none emerging as the panacea for management [4,5]. High-frequency oscillatory ventilation (HFOV) offers theoretical benefit in ARDS management by emphasizing extreme lung protection from excessive volume, but essentially fell out of clinical use after 2 trials in 2013 failed to show clinical benefit, with 1 suggesting increased mortality [6,7]. Like most treatments for ARDS, evidence prior to these trials was mixed, but the negative results of these trials, combined with encouraging results from the CESAR trial investigating veno-venous ECMO [8], essentially sealed the fate of HFOV and eliminated its role in the treatment of ARDS. The impact of COVID, however, has forced the medical community to reconsider treatments from the past while searching for new treatments. With few consistently efficacious therapeutics, extreme lung protection while buying time appears paramount to good outcomes. The impact of oxygen toxicity has come to the fore-front during this pandemic [9], with fibrotic lung disease often developing much quicker than observed with other pathogens. Despite mixed mortality outcomes, a large body of evidence with HFOV prior to COVID supports improved oxygenation with its use [10-12]. The benefit of lower delivered tidal volumes is unquestionable and low-tidal volume ventilation is currently the only therapeutic intervention independently associated with improved survival for patients with ARDS [13]. With this in mind, HFOV offers a potentially useful ventilation strategy for severe ARDS due to COVID-19.

Case Reports

We present 3 cases of respiratory failure due to severe COVID-19 pneumonia managed with HFOV in accordance with the CARE reporting check list. SARS-CoV-2 variants were not available to the treating team, but all 3 cases were encountered during the delta and omicron surges and were assumed to be due to one of these variants. All 3 patients were ventilated using the SensorMedics 3100B oscillator. Management of all 3 was directed by Intensivists with prior training and experience with HFOV prior to the COVID-19 pandemic. The study was conducted in accordance with the Declaration of Helsinki (as revised in 2013). The study was approved by the Institutional Review Board at Lexington Medical Center. Written informed consent was obtained retrospectively from the patients for publication of this case series and accompanying images. A copy of the written consent is available for review by the editorial office of this journal.

Case 1

A 21-year-old unvaccinated, morbidly obese woman (BMI 65) was admitted 6 days after diagnosis of COVID-19. She was hypoxemic in the emergency department (ED) and required emergent intubation. She remained severely hypoxemic despite 100% FiO2 and 22 of PEEP, so inhaled nitric oxide (iNO) was added. She was placed in prone position but continued to require 100% oxygen and high PEEP with elevated mean airway and plateau pressures in the 30s. She demonstrated evidence of sepsis, cytokine storm, and renal failure and was treated with all available therapies for COVID-19 (dexamethasone, baricitinib; no Remdesivir due to renal failure and mechanical ventilation). She remained gravely ill with no clinical improvement and required initiation of continuous renal replacement therapy (CRRT) on day 3. For refractory ARDS, she was placed on HFOV. Settings were set to allow for weaning of oxygen, and to allow for extreme permissive hypercapnia. Her FiO2 was weaned below 60% within the first 24 hours of HFOV, and over the next 2 days her mean airway pressure (MAP) was weaned to maintain saturations of 90%. By day 3 of HFOV she had weaned to acceptable settings and her respiratory acidosis improved. She was transitioned to conventional ventilation with a high PEEP strategy. Over the next 3 days, her PEEP was weaned and neuromuscular blockade discontinued. Given her body habitus, she underwent early tracheostomy on ventilator day 8. Ventilator settings were slowly weaned, she transitioned to tracheostomy collar continuously on hospital day 17, and transferred out of the intensive care unit (ICU) on day 18. She was weaned to room air on day 23. Her renal function recovered, no longer requiring renal replacement therapy, and she discharged home on day 32.

Case 2

A 53-year-old unvaccinated woman presented to the ED with cough, fever, and dyspnea for 1 week. A chest X-ray showed bilateral infiltrates and she was hypoxemic with positive PCR for COVID-19. She required intubation in the ED and was admitted to the ICU. COVID-19 treatments were limited due to shock with renal failure but she was started on corticosteroids and baricitinib. Initial arterial blood gas (ABG) revealed severe hypoxemia and hypercapnia, and iNO was started. Prone ventilation was attempted but she worsened clinically and required emergent supination. With refractory hypoxemia, hypercapnia, and hemodynamic instability on 100% FiO2 and 14 of PEEP, she was placed on HFOV on hospital day 2. She remained critically ill and required vasopressor support along with CRRT for renal failure, acidosis, and volume control. Empiric antibiotics were started for possible superimposed bacterial pneumonia. Mean airway pressure was maintained and oxygen preferentially weaned, with settings again allowing for extreme permissive hypercapnia. Over the next several days, MAP was slowly weaned and she was transitioned to conventional ventilation on hospital day 5. She was managed with a high PEEP strategy, slowly weaned, and underwent tracheostomy on hospital day 17. She was liberated from the ventilator and transferred out of the ICU on hospital day 24. Her tracheostomy tube was removed on day 34 and she was discharged to rehab on hospital day 44 on 2L nasal cannula, still requiring intermittent hemodialysis but with improving urine output, encouraging for eventual renal recovery.

Case 3

A 38-year-old unvaccinated man presented to the ED with progressive dyspnea, cough, and fevers 5 days after being diagnosed with COVID-19. A chest X-ray showed bilateral infiltrates and he was hypoxemic, requiring heated high-flow nasal cannula (HHFNC). He was admitted to the hospital ward and started on dexamethasone, Remdesivir, and baricitinib. He gradually worsened and required transfer to the ICU on hospital day 5. He was intubated on arrival, placed in prone position, and started on iNO. He initially improved and was returned supine. On day 3 of intubation he became more hypoxemic and a chest X-ray revealed subcutaneous emphysema with pneumomediastinum (). Fenestrated subcutaneous catheters were placed but he continued to worsen with worsening hypoxemia, hypercapnia, and worsening subcutaneous emphysema/pneumomediastinum (). He was placed on HFOV, again allowing for permissive hypercapnia and in this case aggressively weaning MAP to avoid further barotrauma. He transitioned off HFOV to conventional ventilation on day 6 of HFOV with a chest X-ray showing improvement of pneumomediastinum and subcutaneous emphysema (). A low tidal volume, a low PEEP strategy was implemented, continuing to allow for hypercapnia. His neuromuscular blocker was discontinued, sedation was weaned, and he was extubated on ventilator day 12. He transferred out of the ICU on hospital day 19, weaned off oxygen, and discharged home on hospital day 28.

Discussion

The management of ARDS changed drastically with the results of the landmark ARMA trial published in 2000, which demonstrated a nearly 9% decrease in mortality utilizing a low-tidal volume strategy [13]. The standard of care became universal seemingly overnight. Prone ventilation, when combined with low tidal volume ventilation has since been demonstrated to further improve survival [2]. Nevertheless, the mortality rate remains unacceptably high, approaching 50% in some populations [14]. The search for other efficacious ventilation strategies and management has remained largely disappointing, with numerous medications and ventilator modalities proving to be largely ineffective. VV ECMO offers promising treatment, in part by limiting tidal volumes to an extreme, but is highly invasive, labor intensive, heavily consumes resources, and is often available only at tertiary medical centers. Furthermore, outcomes for COVID-19 have been inconsistent [5]. Here we present 3 patients, all previously healthy, who rapidly worsened from COVID-19 despite all available medical therapies for COVID-19 and evidence-based ventilator management. While evidence is lacking, inhaled nitric oxide was added in all 3 in an effort to improve oxygenation and limit injurious ventilator settings. With refractory hypoxemia and the availability of HFOV at our institution, our team placed each patient on HFOV. The theoretical advantages of HFOV center around improving oxygenation through increased mean airway pressure while protecting the lungs from the high distending alveolar pressures and tidal volumes associated with increased mortality. The value of low-tidal volume ventilation was established in 2000 as the undeniable standard of care. Results have been confirmed in many trials that have followed, and further analysis from the same trial showed that within the low tidal volume group, patients with lower plateau pressures had longer survival than those with higher plateaus [13]. Management with HFOV allows for extreme lung protection by ventilating using tidal volumes smaller than anatomic dead space, thus maximizing the only know independent lung-protective ventilation intervention. With this strategy often comes the concept of permissive hypercapnia. The safety of this strategy has long been established, trading “normal” ABG results for the benefit of lung-protective tidal volumes. This may be of additional importance in the case of air-leak syndromes, such as patient 3, where targeted tidal volumes may be even lower than traditional goals. Excessive barotrauma has been reported with COVID-19 and is associated with increased morbidity and mortality [15]. HFOV allows for high MAP, with much of the pressures dissipating prior to reaching the distant alveoli, thus allowing for less damage and potentially quicker healing. While safe CO2 and pH values are somewhat arbitrary, we allowed for extreme values, which we determined to be safe based on favorable hemodynamics in our patients. Despite discouraging survival outcomes in the 2 most recent randomized trials on HFOV, most prior evidence does support improved oxygenation using HFOV, particularly when combined with inhaled nitric oxide [10-12,16]. While difficult to quantify, the potential of oxygen toxicity has come to the forefront during the pandemic, with a seemingly abnormal proportion of patients developing irreversible lung damage and fibrosis despite lack of progression to multiple organ failure, which is most often cited at the cause of death from traditional ARDS. With HFOV, our management strategy was to quickly lower FiO2 as low as possible while maintaining mean airway pressures to safely and effectively oxygenate and ventilate. Each of our patients was able to wean quickly, within the first 24 hours of transitioning to HFOV, limiting exposure to high-dose oxygen.

Conclusions

While HFOV has fallen out of favor and should not be routinely utilized in management, we believe it should be considered in select cases when hypoxemia persists and/or standard goals cannot be accomplished. As with any therapy or intervention, it is less likely to be efficacious when used as a rescue therapy and if used, should only be used by experienced clinicians, relatively early in the clinical course of illness.
  16 in total

1.  Prone positioning in severe acute respiratory distress syndrome.

Authors:  Claude Guérin; Jean Reignier; Jean-Christophe Richard; Pascal Beuret; Arnaud Gacouin; Thierry Boulain; Emmanuelle Mercier; Michel Badet; Alain Mercat; Olivier Baudin; Marc Clavel; Delphine Chatellier; Samir Jaber; Sylvène Rosselli; Jordi Mancebo; Michel Sirodot; Gilles Hilbert; Christian Bengler; Jack Richecoeur; Marc Gainnier; Frédérique Bayle; Gael Bourdin; Véronique Leray; Raphaele Girard; Loredana Baboi; Louis Ayzac
Journal:  N Engl J Med       Date:  2013-05-20       Impact factor: 91.245

2.  Severity of Hypoxemia and Effect of High-Frequency Oscillatory Ventilation in Acute Respiratory Distress Syndrome.

Authors:  Maureen O Meade; Duncan Young; Steven Hanna; Qi Zhou; Thomas E Bachman; Casper Bollen; Arthur S Slutsky; Sarah E Lamb; Neill K J Adhikari; Spyros D Mentzelopoulos; Deborah J Cook; Sachin Sud; Roy G Brower; B Taylor Thompson; Sanjoy Shah; Alex Stenzler; Gordon Guyatt; Niall D Ferguson
Journal:  Am J Respir Crit Care Med       Date:  2017-09-15       Impact factor: 21.405

3.  Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome.

Authors:  Roy G Brower; Michael A Matthay; Alan Morris; David Schoenfeld; B Taylor Thompson; Arthur Wheeler
Journal:  N Engl J Med       Date:  2000-05-04       Impact factor: 91.245

4.  Efficacy and economic assessment of conventional ventilatory support versus extracorporeal membrane oxygenation for severe adult respiratory failure (CESAR): a multicentre randomised controlled trial.

Authors:  Giles J Peek; Miranda Mugford; Ravindranath Tiruvoipati; Andrew Wilson; Elizabeth Allen; Mariamma M Thalanany; Clare L Hibbert; Ann Truesdale; Felicity Clemens; Nicola Cooper; Richard K Firmin; Diana Elbourne
Journal:  Lancet       Date:  2009-09-15       Impact factor: 79.321

5.  High-frequency oscillation in early acute respiratory distress syndrome.

Authors:  Niall D Ferguson; Deborah J Cook; Gordon H Guyatt; Sangeeta Mehta; Lori Hand; Peggy Austin; Qi Zhou; Andrea Matte; Stephen D Walter; Francois Lamontagne; John T Granton; Yaseen M Arabi; Alejandro C Arroliga; Thomas E Stewart; Arthur S Slutsky; Maureen O Meade
Journal:  N Engl J Med       Date:  2013-01-22       Impact factor: 91.245

6.  Pulmonary Barotrauma in COVID-19 Patients With ARDS on Invasive and Non-Invasive Positive Pressure Ventilation.

Authors:  Kartikeya Rajdev; Alan J Spanel; Sean McMillan; Shubham Lahan; Brian Boer; Justin Birge; Meilinh Thi
Journal:  J Intensive Care Med       Date:  2021-05-20       Impact factor: 3.510

7.  Airway pressure release ventilation in mechanically ventilated patients with COVID-19: a multicenter observational study.

Authors:  John S Zorbas; Kwok M Ho; Edward Litton; Bradley Wibrow; Edward Fysh; Matthew H Anstey
Journal:  Acute Crit Care       Date:  2021-05-04

8.  Surviving Sepsis Campaign: guidelines on the management of critically ill adults with Coronavirus Disease 2019 (COVID-19).

Authors:  Waleed Alhazzani; Morten Hylander Møller; Yaseen M Arabi; Mark Loeb; Michelle Ng Gong; Eddy Fan; Simon Oczkowski; Mitchell M Levy; Lennie Derde; Amy Dzierba; Bin Du; Michael Aboodi; Hannah Wunsch; Maurizio Cecconi; Younsuck Koh; Daniel S Chertow; Kathryn Maitland; Fayez Alshamsi; Emilie Belley-Cote; Massimiliano Greco; Matthew Laundy; Jill S Morgan; Jozef Kesecioglu; Allison McGeer; Leonard Mermel; Manoj J Mammen; Paul E Alexander; Amy Arrington; John E Centofanti; Giuseppe Citerio; Bandar Baw; Ziad A Memish; Naomi Hammond; Frederick G Hayden; Laura Evans; Andrew Rhodes
Journal:  Intensive Care Med       Date:  2020-03-28       Impact factor: 17.440

9.  Prone positioning for patients intubated for severe acute respiratory distress syndrome (ARDS) secondary to COVID-19: a retrospective observational cohort study.

Authors:  Tyler T Weiss; Flor Cerda; J Brady Scott; Ramandeep Kaur; Sarah Sungurlu; Sara H Mirza; Amnah A Alolaiwat; Ramandeep Kaur; Ashley E Augustynovich; Jie Li
Journal:  Br J Anaesth       Date:  2020-10-10       Impact factor: 9.166

10.  Hyperoxia and modulation of pulmonary vascular and immune responses in COVID-19.

Authors:  Dusan Hanidziar; Simon C Robson
Journal:  Am J Physiol Lung Cell Mol Physiol       Date:  2020-10-14       Impact factor: 5.464