Mucus clearance by two-phase gas-liquid flow mechanism: asymmetric periodic flow model.

C S Kim, A J Iglesias, M A Sackner.   

Abstract

Mucus transport by two-phase gas-liquid flow mechanism was investigated with in vitro flow models under asymmetric periodic airflow conditions with nine different liquid solutions with rheological properties similar to human sputum. The flow model was made with 1.0-cm-ID glass tube and positioned either vertically or horizontally. With a constant supply of the test liquids into the model tube (0.5 ml/min), the liquid layer transport speed (LLTS) as well as the mean liquid layer thickness at steady-state condition (hs) was measured in conjunction with various airflow patterns of different expiratory and inspiratory flow rate, breathing frequency (f), and tidal volume (VT). The flow patterns were maintained within the range of normal breathing. In the horizontal tube model, LLTS ranged from 1.14 +/- 0.02 to 3.39 +/- 0.04 cm/min at the peak expiratory flow rate (VEp) of 30-60 l/min. The inspiratory flow rate, as well as f and VT did not affect LLTS. However, LLTS increased with increasing VEp, and at the same VEp LLTS was higher with viscoelastic than with viscous liquid. In the vertical tube model, the upward transport of mucus could not be achieved at VEp lower than 30 l/min particularly with low viscosity and low elasticity fluid. However, at high values of VEp, LLTS was comparable to that in the horizontal tube model with viscoelastic fluid, whereas LLTS of viscous liquid showed 26-40% lower than that in the horizontal tube model. The value of hs was 5-20% of the tube diameter at VEp of 30-60 l/min in both models. These results indicate that effective mucus clearance can be achieved by two-phase gas-liquid flow mechanism in patients with excessive bronchial secretions with biased tidal breathing favoring the expiratory flow and that the clearance can be further promoted by changing rheological properties of mucus.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3571095     DOI: 10.1152/jappl.1987.62.3.959

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  18 in total

Review 1.  Structure and function of the mucus clearance system of the lung.

Authors:  Brenda M Button; Brian Button
Journal:  Cold Spring Harb Perspect Med       Date:  2013-08-01       Impact factor: 6.915

2.  Airway Clearance with Expiratory Flow Accelerator Technology: Effectiveness of the "Free Aspire" Device in Patients with Severe COPD.

Authors:  Giorgia Patrizio; Michele D'Andria; Francesco D'Abrosca; Antonella Cabiaglia; Fabio Tanzi; Giancarlo Garuti; Antonello Nicolini
Journal:  Turk Thorac J       Date:  2019-07-30

3.  Effect of multimodality chest physiotherapy in prevention of ventilator-associated pneumonia: A randomized clinical trial.

Authors:  Renu B Pattanshetty; G S Gaude
Journal:  Indian J Crit Care Med       Date:  2010-04

Review 4.  Airway clearance techniques for bronchiectasis.

Authors:  Annemarie L Lee; Angela T Burge; Anne E Holland
Journal:  Cochrane Database Syst Rev       Date:  2015-11-23

5.  Continuum-kinetic-microscopic model of lung clearance due to core-annular fluid entrainment.

Authors:  Sorin Mitran
Journal:  J Comput Phys       Date:  2013-07-01       Impact factor: 3.553

6.  Manual hyperinflation partly prevents reductions of functional residual capacity in cardiac surgical patients--a randomized controlled trial.

Authors:  Frederique Paulus; Denise P Veelo; Selma B de Nijs; Ludo F M Beenen; Paul Bresser; Bas A J M de Mol; Jan M Binnekade; Marcus J Schultz
Journal:  Crit Care       Date:  2011-08-05       Impact factor: 9.097

7.  Effects of treadmill exercise versus Flutter® on respiratory flow and sputum properties in adults with cystic fibrosis: a randomised, controlled, cross-over trial.

Authors:  Tiffany J Dwyer; Rahizan Zainuldin; Evangelia Daviskas; Peter T P Bye; Jennifer A Alison
Journal:  BMC Pulm Med       Date:  2017-01-11       Impact factor: 3.317

8.  Comparing airways clearance techniques in chronic obstructive pulmonary disease and bronchiectasis: positive expiratory pressure or temporary positive expiratory pressure? A retrospective study.

Authors:  Francesco D'Abrosca; Barbara Garabelli; Gloria Savio; Agnese Barison; Lorenzo Appendini; Luis V F Oliveira; Paola Baiardi; Bruno Balbi
Journal:  Braz J Phys Ther       Date:  2017-01-13       Impact factor: 3.377

Review 9.  Benefits and risks of manual hyperinflation in intubated and mechanically ventilated intensive care unit patients: a systematic review.

Authors:  Frederique Paulus; Jan M Binnekade; Margreeth B Vroom; Marcus J Schultz
Journal:  Crit Care       Date:  2012-08-03       Impact factor: 9.097

10.  Experimental study on the efficiency and safety of the manual hyperinflation maneuver as a secretion clearance technique.

Authors:  Tatiana de Arruda Ortiz; Germano Forti; Márcia Souza Volpe; Carlos Roberto Ribeiro Carvalho; Marcelo Brito Passos Amato; Mauro Roberto Tucci
Journal:  J Bras Pneumol       Date:  2013 Mar-Apr       Impact factor: 2.624

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.