| Literature DB >> 35707469 |
Maoting Lv1, Shanshan Yu2, Yongzhen Li3, Xiaoting Zhang1, Dan Zhao3.
Abstract
Objective: To evaluate the ultrasound multiparametric assessment of the impact of hypertensive disorders of pregnancy (HDP) on fetal cardiac function and growth and development.Entities:
Year: 2022 PMID: 35707469 PMCID: PMC9192324 DOI: 10.1155/2022/3419966
Source DB: PubMed Journal: Evid Based Complement Alternat Med ISSN: 1741-427X Impact factor: 2.650
Comparison of baseline characteristics ( ± s).
| Groups |
| Age | Mean age | Gestational week | Mean gestational week |
|---|---|---|---|---|---|
| Study group | 98 | 24–35 | 28.17 ± 4.02 | 26–30 | 28.01 ± 1.81 |
| Control group | 100 | 24–34 | 28.05 ± 4.18 | 26–30 | 28.15 ± 1.41 |
|
| — | — | 0.206 | — | 0.608 |
|
| — | — | 0.837 | — | 0.544 |
Comparison of clinical data ( ± s).
| Groups |
| Systolic blood pressure (mmHg) | Diastolic blood pressure (mmHg) | 24 h urine protein quantification (g/24 h) |
|---|---|---|---|---|
| Study group | 98 | 152.65 ± 7.16 | 101.47 ± 4.28 | 3.08 ± 0.77 |
| Control group | 100 | 108.34 ± 6.12 | 62.37 ± 4.53 | 0.08 ± 0.02 |
|
| — | 46.842 | 62.404 | 38.950 |
|
| — | <0.001 | <0.001 | <0.001 |
Comparison of fetal growth and development ( ± s).
| Groups |
| HC | BPD | FL | AC |
|---|---|---|---|---|---|
| Study group | 98 | 31.65 ± 2.81 | 8.82 ± 0.76 | 6.79 ± 0.58 | 30.88 ± 3.29 |
| Control group | 100 | 32.94 ± 1.93 | 9.18 ± 0.53 | 7.02 ± 0.53 | 32.77 ± 2.38 |
|
| — | 3.772 | 3.873 | 2.914 | 4.638 |
|
| — | <0.001 | <0.001 | 0.004 | <0.001 |
Comparison of ultrasound hemodynamic parameters ( ± s).
| Index | Study group ( | Control group ( |
|
| |
|---|---|---|---|---|---|
| UA | RI | 0.89 ± 0.18 | 0.66 ± 0.12 | 10.599 | <0.001 |
| PI | 1.21 ± 0.23 | 1.08 ± 0.13 | 4.909 | <0.001 | |
|
| |||||
| AoI | RI | 0.71 ± 0.10 | 0.87 ± 0.17 | 8.051 | <0.001 |
| PI | 1.96 ± 0.25 | 2.32 ± 0.38 | 7.859 | <0.001 | |
|
| |||||
| DV | RI | 0.63 ± 0.17 | 0.48 ± 0.12 | 7.184 | <0.001 |
| PI | 0.86 ± 0.19 | 0.64 ± 0.13 | 9.525 | <0.001 | |
|
| |||||
| PV | RI | 0.68 ± 0.11 | 0.52 ± 0.08 | 11.722 | <0.001 |
| PI | 1.03 ± 0.18 | 0.83 ± 0.12 | 9.216 | <0.001 | |
Comparison of fetal heart function parameters ( ± s).
| Index | Study group ( | Control group ( |
|
| |
|---|---|---|---|---|---|
| Ventricular IVCT | Left | 48.33 ± 6.98 | 38.65 ± 5.18 | 11.097 | <0.001 |
| Right | 52.88 ± 12.08 | 42.61 ± 9.52 | 6.551 | <0.001 | |
|
| |||||
| Ventricular IVRT | Left | 48.86 ± 7.02 | 40.91 ± 6.77 | 8.112 | <0.001 |
| Right | 49.98 ± 11.02 | 40.32 ± 8.13 | 7.029 | <0.001 | |
|
| |||||
| Ventricular MPI | Left | 0.53 ± 0.11 | 0.42 ± 0.07 | 8.412 | <0.001 |
| Right | 0.57 ± 0.11 | 0.47 ± 0.09 | 7.007 | <0.001 | |
|
| |||||
| Valve | Mitral | 0.29 ± 0.05 | 0.34 ± 0.09 | 4.819 | <0.001 |
| Tricuspid | 0.32 ± 0.04 | 0.41 ± 0.11 | 7.621 | <0.001 | |
|
| |||||
| Valve | Mitral | 0.49 ± 0.14 | 0.58 ± 0.11 | 5.035 | <0.001 |
| Tricuspid | 0.51 ± 0.05 | 0.62 ± 0.14 | 7.333 | <0.001 | |
Note. Only parameters with statistically significant (P < 0.05) differences are shown. The values of left and right ventricular ET and mitral and tricuspid A values were not significant between the two groups (P > 0.05).
Correlation of ultrasound parameters with clinical data.
| Index |
|
|
|---|---|---|
| Systolic pressure | ||
| UA PI | 0.761 | <0.01 |
| UA RI | 0.739 | <0.01 |
| AoI PI | −0.842 | <0.01 |
| AoI RI | −0.801 | <0.01 |
| DV PI | 0.802 | <0.01 |
| DV RI | 0.759 | <0.01 |
| PV PI | 0.793 | <0.01 |
| PV RI | 0.762 | <0.01 |
| Left ventricular IVCT | 0.748 | <0.01 |
| Left ventricular IVRT | 0.752 | <0.01 |
| Left ventricular MPI | 0.838 | <0.01 |
| Right ventricular IVCT | 0.747 | <0.01 |
| Right ventricular IVRT | 0.749 | <0.01 |
| Right ventricular MPI | 0.801 | <0.01 |
| Mitral valve | −0.785 | <0.01 |
| Mitral valve | −0.802 | <0.01 |
| Tricuspid valve | −0.774 | <0.01 |
| Tricuspid valve | −0.816 | <0.01 |
Note. Only parameters with correlation (P < 0.05) are shown. There was no correlation between left and right ventricular ET and mitral and tricuspid A parameter values and systolic blood pressure (P > 0.05). All ultrasound parameters did not correlate with diastolic blood pressure and 24 h urine protein quantification (all P > 0.05).
Comparison of umbilical artery blood flow parameters for different fetal growth and development ( ± s).
| Groups |
| S/D | PI | RI |
|---|---|---|---|---|
| Study group A | 39 | 3.89 ± 0.98 | 1.29 ± 0.33 | 0.79 ± 0.16 |
| Study group B | 59 | 2.50 ± 0.66 | 0.91 ± 0.31 | 0.63 ± 0.08 |
|
| — | 8.397 | 5.789 | 6.552 |
|
| — | <0.001 | <0.001 | <0.001 |
Note. Study group A, fetal growth restriction; study group B, normal fetal growth.
Comparison of fetal cardiac function parameters between the two groups ( ± s).
| Items | Cut-off value | AUC | Sensitivity (%) | Specificity (%) | Youden index |
|---|---|---|---|---|---|
| S/D | 3.53 | 0.883 | 63.88 | 96.85 | 0.607 |
| PI | 1.02 | 0.801 | 83.45 | 65.61 | 0.492 |
| RI | 0.71 | 0.842 | 75.02 | 86.42 | 0.616 |
Note. AUC refers to the area under the curve.