Literature DB >> 35703658

The Volume-Time Curve by Three-Dimensional Echocardiography in Chagas Cardiomyopathy: Insights into the Mechanism of Hemodynamic Adaptations.

Airandes de Sousa Pinto1,2, Maria Carmo Pereira Nunes3, Carlos Alberto Rodrigues2, Bráulio Muzzi Ribeiro de Oliveira4, João da Rocha Medrado Neto1, Timothy C Tan5, Manoel Otavio da Costa Rocha3.   

Abstract

BACKGROUND: Three-dimensional echocardiography (3D ECHO) allows the generation of a volume-time curve representative of changes in the left ventricular (LV) volume throughout the entire cardiac cycle.
OBJECTIVE: This study aims to demonstrate the hemodynamic adaptations present in Chagas cardiomyopathy (CC) by means of the volume and flow measurements obtained by the volume-time curve by 3D ECHO.
METHODS: Twenty patients with CC and 15 healthy subjects were prospectively enrolled in a cross-sectional design study. 3D ECHO was performed in all subjects and the volume over time curves of the LV was generated. The flow was obtained by the first derivative of the volume-time curve using the software MATLAB. Statistical significance was set at p<0.05.
RESULTS: Although CC patients had lower LV ejection fraction compared to the control group (29.8±7.5 vs. 57.7±6.1, p<0.001), stroke volume (61.5±25.2 vs. 53.8±21.0, p=0.364) and maximum ejection flow during systole (-360.3±147.5 vs. -305.6±126.0, p=0.231) were similar between the groups. Likewise, the maximum flow in the early diastolic filling phase and during atrial contraction was similar between groups. An increase in preload expressed by LV end diastolic volume (204.8±79.4 vs. 93.0±32.6), p<0.001) may maintain the flow and stroke volumes similar to the controls.
CONCLUSION: Using a non-invasive tool, we demonstrated that an increase in LV end-diastolic volume may be the main adaptation mechanism that maintains the flow and stroke volumes in the setting of severe LV systolic dysfunction.

Entities:  

Mesh:

Year:  2022        PMID: 35703658      PMCID: PMC9345165          DOI: 10.36660/abc.20201308

Source DB:  PubMed          Journal:  Arq Bras Cardiol        ISSN: 0066-782X            Impact factor:   2.667


Introdução

Os métodos atuais de ecocardiografia bidimensional (2D) para avaliação do volume ventricular esquerdo (VE) são limitados pela variabilidade inter-observador e por premissas geométricas.[1] O advento da ecocardiografia tridimensional (ECO 3D) permitiu que os volumes ventriculares fossem avaliados sem o uso de quaisquer premissas geométricas, permitindo a geração de uma curva volume-tempo representativa das alterações no volume do VE ao longo de todo o ciclo cardíaco, estando, portanto, muito menos sujeitos à variabilidade do observador devido à detecção semiautomática das bordas do VE.[2] No entanto, atualmente, o ECO 3D vir usado para a avaliação morfológica das estruturas cardíacas, a avaliação hemodinâmica ainda é realizada por meio de variáveis ecocardiográficas 2D, incluindo dimensão e velocidade na equação da continuidade. Embora as medidas uniplanares das dimensões VE sejam rotineiramente usadas para avaliar o aumento da câmara cardíaca, as medidas de volume 3D representam melhor a dilatação geral da câmara.[1] Além disso, as medidas do fluxo instantâneo dentro de uma câmara cardíaca podem ser obtidas usando dados da primeira derivada das curvas de volume. Esta abordagem não invasiva para a caracterização da dilatação das câmaras cardíacas não foi estudada em pacientes com cardiomiopatia chagásica. Portanto, este estudo tem como objetivo demonstrar as adaptações hemodinâmicas presentes na cardiomiopatia chagásica por meio das medidas de volume e fluxo obtidas pela curva volume-tempo por meio da ecocardiografia 3D.

Métodos

Um total de 44 pacientes com cardiomiopatia chagásica foram inicialmente recrutados para o estudo. Foram excluídos pacientes com hipertensão arterial, fibrilação atrial, cardiopatia valvar, cardiopatia congênita, pericardiomiopatia e portadores de marca-passo. Com base nesses critérios de exclusão, 24 pacientes foram excluídos e 20 pacientes foram incluídos no estudo (fluxograma do estudo, Figura 1 ). Os participantes do grupo controle não apresentavam histórico clínica de doença cardiovascular. Os exames clínico e ecocardiográfico estavam normais.
Figura 1

– Fluxograma do estudo.

Definiu-se cardiomiopatia chagásica como presença de fração de ejeção VE menor ou igual a 54% e diâmetro diastólico final VE maior que 56 mm. O estudo ecocardiográfico foi realizado por um único examinador, utilizando-se ecocardiógrafo IE 33-Philips de acordo com o protocolo da Sociedade Americana de Ecocardiografia.[3] Realizou-se ecocardiografia tridimensional em todos os participantes com um transdutor X3-1. As curvas volume-tempo do ventrículo esquerdo foram geradas pelo software próprio Qlab ( Figura 2 , A). Essas curvas geraram o volume diastólico final ventricular esquerdo, o volume sistólico final ventricular esquerdo e o volume sistólico. A curva de volume foi criada em intervalos de cerca de 03 ms. O software MATLAB versão R2017a gerou um polinômio ajustado para a curva de volume ventricular esquerda ( Figura 2 , B). A correlação entre as curvas de volume geradas pelo Qlab e o polinômio obtido pelo Mathlab apresentou r≥0,99 em todos os pacientes.
Figura 2

– A) Curva de volume do ventrículo esquerdo gerada pelo software Qlab em paciente com cardiomiopatia chagásica. B) Representação da curva de volume do ventrículo esquerdo, em preto, gerada pelo software Qlab e o intervalo do polinômio gerado pelo software MATLAB, em vermelho. C) Curva de fluxo obtida em paciente com cardiomiopatia chagásica durante o ciclo cardíaco. Valores negativos ocorrem durante a sístole e valores positivos durante a diástole. QS= Fluxo sistólico máximo absoluto, QE= fluxo de pico durante o enchimento ventricular esquerdo precoce. QA = pico de fluxo durante a contração atrial. D) Boxplot do valor absoluto do volume diastólico final do QS/VE de acordo com o grupo de estudo.

Os valores de fluxo durante o ciclo cardíaco ( Figura 2 , C) foram obtidos pela primeira derivada do polinômio representativo da curva de volume. Para nossa análise, utilizamos o fluxo máximo durante a sístole, enchimento precoce e contração atrial ( Figura 2 , C). Além disso, calculamos a razão entre o fluxo sistólico máximo e volume diastólico final ventricular esquerdo (QS/VDFVE) ( Figura 2 , D).

Análise estatística

O estudo foi projetado para atingir 95% de poder para detectar uma redução de 50% na razão entre o pico do fluxo sistólico instantâneo (QS) e o volume diastólico final VE em pacientes com cardiomiopatia chagásica em comparação com o grupo controle com base nos valores obtidos por Marshall et al. (n1=12, n2=10, média x1=3,4 seg-1 e x2 = 1,22 seg-1).4 Portanto, considerando um erro alfa de 0,05 e uma razão paciente: controle de 1, obteve-se uma amostra de 3 pacientes e 3 controles. Para os cálculos, utilizou-se o software G Power versão 3.1. Utilizou-se o teste do qui-quadrado para comparar as variáveis categóricas entre os grupos. As variáveis contínuas com distribuição normal foram expressas como média±desvio padrão ou como mediana ou intervalo interquartil se apresentassem distribuição não normal. Utilizou-se o teste de Shapiro-Wilk para avaliar a normalidade das variáveis. Utilizou-se o teste t de Student não pareado para comparar variáveis contínuas com distribuição normal e o teste de Mann-Whitney para comparar variáveis com distribuição não normal entre os grupos. As correlações foram realizadas pelo método de Pearson. A significância estatística foi definida como p<0,05. Todas as análises foram realizadas utilizando o software SPSS versão 15.0 (SPSS Inc., Chicago, IL). O Comitê de Ética da Universidade Federal de Minas Gerais (CAAE:48354315.8.3001.5091) aprovou o estudo, e o consentimento informado por escrito foi obtido de todos os pacientes.

Resultados

Vinte pacientes com CC, idade média de 45±12, 55% do sexo masculino, foram comparados com 15 controles saudáveis pareados por sexo e idade. Não houve diferença de sexo entre pacientes e controles. As características ecocardiográficas da população estudada encontram-se na tabela 1 . A maioria dos pacientes (70%) apresentava dispneia aos esforços, em tratamento para insuficiência cardíaca, principalmente com inibidores da enzima conversora da angiotensina e betabloqueadores ( Tabela 2 ).
Tabela 1

Características ecocardiográficas da população estudada

Variável*Cardiomiopatia chagásica (n=20)Controles (n=15)Valor de p
Diâmetro diastólico final VE (mm)68,4±9,246,6±4,2<0,001
Diâmetro sistólico final VE (mm)56,1±10,830,1±3,7<0,001
Volume diastólico final VE (mL)204,8±79,493,0±32,6<0,001
Volume sistólico final VE (mL)143,3±60,839,2±13,6<0,001
Volume sistólico (mL)61,5±25,253,8±21,00,364
Fração de ejeção VE 3D (%)29,8±7,557,7±6,1<0,001
QS (mL/s)- 360,3±147,5-305,6±126,00,231
QS/volume diastólico final VE (s-1)1,80±0,403,28±0,64<0,001
QE (mL/s)270,4±135,3201,9±61,50,104
QA (mL/s)134,4±88,1109,1±37,80,623
QE/QA2,2±1,31,8±0,50,382
Velocidade de pico mitral E (m/s)81,0±30,281,9±19,50,921
Tempo de desaceleração (ms)166,5 (79)190,0 (38)0,290
Velocidade de pico mitral A (m/s)51,2±24,555,4±15,60,583
Razão E/A mitral1,9±1,11,6±0,60,404
Razão E/e’15,2±9,37,6±1,70,002

Os dados são expressos como média±desvio padrão ou mediana (intervalo interquartil). VE: ventricular esquerdo; QS: pico de fluxo sistólico instantâneo; QE: pico de fluxo durante o enchimento ventricular esquerdo inicial; QA: pico de fluxo durante a contração atrial.

Tabela 2

Medicamentos usados pelos 20 pacientes com cardiomiopatia chagásica crônica dilatada

MedicaçõesNúmero de pacientes (%)
Diuréticos19 (95)
Espironolactona5 (25)
Inibidores da enzima conversora da angiotensina16 (80)
Antagonistas dos receptores de angiotensina3 (15)
Digoxina13 (65)
Amiodarona6 (30)
Terapia anticoagulante8 (40)
Betabloqueadores17 (85)
Aspirina1 (5)
Os dados são expressos como média±desvio padrão ou mediana (intervalo interquartil). VE: ventricular esquerdo; QS: pico de fluxo sistólico instantâneo; QE: pico de fluxo durante o enchimento ventricular esquerdo inicial; QA: pico de fluxo durante a contração atrial. A frequência cardíaca (batimentos por minuto) foi semelhante entre a cardiomiopatia chagásica e o grupo controle — 62,4±10,2 vs. 66,1±11,0, p=0,3, respectivamente. Os pacientes com CC apresentaram maiores volumes diastólico e sistólico final de VE e menor fração de ejeção VE, em comparação ao grupo controle. No entanto, o volume ejetado e o fluxo de ejeção máximo durante a sístole (QS) foram semelhantes entre os grupos. Houve uma forte correlação entre o QS e o volume sistólico: r=0,91, p<0,001. O grupo CC apresentou uma razão QS/volume diastólico final do VE menor em comparação com os controles ( Figura 2 , D). A razão QS/volume diastólico final do VE apresentou forte correlação com a fração de ejeção: r=0,89, p<0,001. A avaliação por Doppler da velocidade mitral não mostrou nenhuma diferença em E, A, razão E/A e tempo de desaceleração da onda E. Como esperado, os pacientes com CC apresentaram aumento da pré-carga em comparação ao grupo controle, demonstrado pelo aumento do volume diastólico final do VE e da razão E/e’. O fluxo máximo na fase de enchimento passivo e precoce (QE) e durante a contração atrial (QA) se mostrou semelhante entre pacientes e controles.

Discussão

Em nosso estudo, avaliamos as adaptações hemodinâmicas do VE na CC por meio de curvas de volume e fluxo por ecocardiografia 3D em comparação a um grupo controle. Embora os pacientes com CC tivessem função sistólica VE severa com fração de ejeção de 30%, o volume ejetado foi semelhante ao grupo controle. Essa discrepância pode ser explicada pelos mecanismos adaptativos que ocorrem na disfunção sistólica crônica do VE.[5 , 6] O ventrículo com baixa fração de ejeção, mas com volume diastólico final elevado, ejeta a mesma quantidade de sangue que um ventrículo com volume diastólico final e fração de ejeção normais.[7] Isso se deve à preservação do mecanismo de Frank-Starling na CC em repouso, o que está de acordo com os achados de Holubasch et al.[5] A ecocardiografia tridimensional permite a medição não invasiva da pré-carga, apresentando alta precisão. O volume diastólico final do VE é a melhor representação da pré-carga, que expressa o grau de estiramento do miocárdio antes da contração. As limitações na avaliação precisa do volume ventricular por métodos ecocardiográficos padrão levam ao uso de pressões de enchimento ventricular como medida substituta da pré-carga. No entanto, a relação entre as pressões de enchimento e o volume ventricular não é linear, dependendo da complacência da câmara cardíaca esquerda.[8] A curva volume-tempo pela ecocardiografia 3D também fornece informações para o cálculo do fluxo em qualquer estágio do ciclo cardíaco. Em nosso estudo, o fluxo foi obtido por interpolação polinomial. A interpolação polinomial é um método preciso de baixa complexidade que permite medir a variação de qualquer curva derivável. Recentemente, usamos essa ferramenta para realizar uma análise da taxa de crescimento da Covid-19.[9 , 10] O fluxo máximo de ejeção (QS) se mostrou semelhante entre os grupos, não refletindo a função sistólica do ventrículo esquerdo. A forte correlação entre o QS absoluto e o volume ejetado sugere que o mesmo mecanismo que normalizou o volume sistólico (VS) competiu pela normalização do QS. Portanto, o QS/volume diastólico final do VE retira o efeito da dilatação ventricular esquerda, que é o aumento da pré-carga, e produz uma variável que permite avaliar a função sistólica global do VE. De fato, em nosso estudo, o QS absoluto/volume diastólico final do VE foi menor nos pacientes que tinham CC do que nos controles normais, o que está de acordo com os achados de outros autores.[4 , 11 , 12] Esse artifício é o mesmo usado para calcular a fração de ejeção. Dividindo-se o VS pelo volume diastólico final do ventrículo esquerdo, o resultado é mais do que uma porcentagem do volume final do ventrículo esquerdo que é ejetado. A proporção representa a normalização do volume sistólico pelo representante da pré-carga: o volume final do VE. Como a pré-carga é um dos determinantes da função sistólica, isso pode explicar a importância prognóstica da fração de ejeção nas cardiomiopatias. Da mesma forma, Hammersmeister et al.,[11] validaram um método de avaliação do volume e fluxo VE em 1974, em diversas doenças cardiovasculares, por cateterismo cardíaco.[11] O volume ventricular foi calculado por ventriculografia na frequência de 60 quadros/s, pelo método área-comprimento. O fluxo foi obtido pela primeira derivada do polinômio que se aproximou da curva de volume. No entanto, esse método é limitado devido à sua natureza invasiva. Por outro lado, em nosso estudo, obtivemos a curva de volume VE durante o ciclo cardíaco com frequência três vezes maior do que método semelhante ao descrito por Hammermeister et al.,[11] Além disso, encontramos uma forte correlação entre o polinômio e a curva de volume VE, permitindo o cálculo do fluxo com grande precisão. A ausência de diferença entre os valores do fluxo diastólico entre os grupos também foi observada por Hammermeister et al.,[13] O comportamento em “U” dessas variáveis frente à piora da função diastólica explica esses resultados, conforme observado por Ohno et al.,[6] em um estudo experimental.[6] Apesar disso, a razão E/e’ foi maior no grupo com CC do que no grupo controle, o que está de acordo com os achados de Oliveira et al.,[14] que observaram que essa variável foi um preditor independente para nível elevado de peptídeo natriurético tipo B (BNP) na CC.[14] A ecocardiografia tridimensional permite revisitar os estudos experimentais do início do século passado, quando o mecanismo de Frank-Starling foi descrito e os fatores mecânicos relacionados ao volume e os fatores mecânicos relacionados ao volume ejetado, reconhecido na época como uma medida da função cardíaca, foram estudados.[15] Este estudo teve as seguintes limitações: a função diastólica do ventrículo esquerdo não foi classificada, mas foram tomados os parâmetros para avaliar a função diastólica. Os valores normais para o QS/volume diastólico final VE basearam-se nos controles, que podem não ser os valores de referência. Finalmente, a importância clínica e as implicações prognósticas desses achados ainda não são totalmente conhecidas. No entanto, este estudo teve como objetivo demonstrar as adaptações hemodinâmicas presentes na cardiomiopatia chagásica por meio das medidas de volume e fluxo obtidas pela curva volume-tempo.

Conclusões

Nosso estudo mostra que o fluxo sistólico instantâneo e o volume ejetado foram semelhantes entre pacientes com disfunção ventricular grave devido a CC e controles saudáveis. Utilizando uma ferramenta não invasiva pela primeira vez na CC, demonstramos que o aumento no volume diastólico final VE, que é uma medida da pré-carga ventricular, é o principal mecanismo de adaptação que mantém o fluxo e o volume ejetado no cenário de disfunção sistólica severa. O QS/volume diastólico final VE, no presente estudo, mostrou-se representativo da função sistólica global do ventrículo esquerdo, cuja utilidade e valor prognóstico devem ser estudados em pesquisas cuja utilidade e valor prognóstico devem ser estudados em pesquisas posteriores.

Introduction

Current two-dimensional (2D) echocardiography methods for the assessment of left ventricular (LV) volume are limited by observer variability, and geometric assumptions.[1] The advent of three-dimensional echocardiography (3D ECHO) allowed ventricular volumes assessed without using any geometric assumptions, allowing the generation of a volume-time curve representative of changes in LV volume throughout the entire cardiac cycle, thus much less subject to observer variability due to the semiautomated detection of LV edges.[2] However, currently 3D ECHO has been used for morphological evaluation of cardiac structures, but hemodynamic evaluation is still performed using 2D echocardiographic variables, including dimension and velocity in the continuity equation. Although single plane measurements of LV size are routinely used to evaluate cardiac chamber enlargement, 3D volume measurements best represent overall chamber dilatation.[1] In addition, measurements of instantaneous flow within a cardiac chamber can be obtained using data from the first derivative of volume curves. This non-invasive approach for characterization of cardiac chamber dilatation has not been studied in patients with Chagas cardiomyopathy. Therefore, this study aims to demonstrate the hemodynamic adaptations present in Chagas cardiomyopathy using the measures of volume and flow obtained by volume-time curve using 3D echocardiography.

Methods

A total of 44 patients presenting Chagas cardiomyopathy were initially recruited for the study. Patients with arterial hypertension, atrial fibrillation, valvular heart disease, congenital heart disease, pericardiomyopathy, and those who had pacemakers were excluded. Based on these exclusion criteria, 24 patients were excluded and 20 patients were included in the study (study flowchart, Figure 1 ). The individuals in the control group had no clinical history of cardiovascular disease. Clinical and echocardiographic examinations were normal.
Figure 1

– Study population flow chart.

Chagas cardiomyopathy was defined as the presence of LV ejection fraction smaller than or equal to 54% and LV end-diastolic diameter greater than 56 mm. The echocardiographic study was performed by a single examiner, using a IE 33-Philips echocardiograph according to the protocol of the American Society of Echocardiography.[3] Three-dimensional echocardiography was performed in all subjects using a X3-1 transducer. The volume-time curves of the left ventricle were generated by proprietary software Qlab ( Figure 2 , A). These curves yielded left ventricular end-diastolic volume, left ventricular end-systolic volume and stroke volume. The volume curve was generated at intervals of around 3 ms. The software MATLAB version R2017a generated a polynomial adjusted to the left ventricular volume curve ( Figure 2 , B). The correlation between the volume curves generated by Qlab and the polynomial obtained by Mathlab presented r≥0.99 in all patients.
Figure 2

– A) Left ventricular volume curve generated by Qlab software in a patient with Chagas cardiomyopathy. B) Representation of the left ventricular volume curve, in black, generated by the Qlab Software and the interval of the polynomial generated by the MATLAB software, in red. C) Flow curve obtained in a patient with Chagas cardiomyopathy during the cardiac cycle. Negative values occur during systole and positive values during diastole. QS= Absolute maximum systolic flow, QE= peak flow during early left ventricular filling. QA = peak flow during atrial contraction. D) Boxplot of the absolute value of the QS/LV end-diastolic volume according to the study group.

The flow values during cardiac cycle ( Figure 2 , C) were obtained by the first derivative of the representative polynomial of the volume curve. For our analysis, we used the maximum flow during systole, early filling and atrial contraction ( Figure 2 , C). In addition, we calculated the maximum flow systole divided by left ventricular end-diastolic volume (QS/LVEDV) ( Figure 2 , D).

Statistical analysis

This study was designed to achieve 95% power to detect a 50% reduction in the ratio between peak instantaneous systolic flow (QS) and LV end-diastolic volume in patients with Chagas cardiomyopathy compared to the control group based on the values obtained by Marshall et al. (n1=12, n2=10, mean x1=3.4 sec-1and x2=1.22 sec-1).[4] Therefore, considering an alpha error of 0.05 and a patient:control ratio of 1, a sample of 3 patients and 3 controls was obtained. For the calculations, the G Power software version 3.1 was used. Chi-square test was used to compare the categorical variables between the groups. The continuous variables with normal distribution were expressed as mean±standard deviation or as median or interquartile range if they presented a non-normal distribution. We used the Shapiro-Wilk test to assess the normality of the variables. Unpaired Student’s t test was used to compare continuous variables with normal distribution, and the Mann-Whitney test was used to compare variables with non-normal distribution between the groups. The correlations were performed using the Pearson method. Statistical significance was set at p<0.05. All analyzes were performed using the software SPSS version 15.0 (SPSS, Inc., Chicago, IL). This study was approved by the Research Ethics Committee of Universidade Federal de Minas Gerais (CAAE:48354315.8.3001.5091) and written informed consent was obtained from all patients.

Results

Twenty patients with CC, mean age 45±12, 55% males, were compared with 15 sex- and age-matched healthy controls. There was no sex difference between patients and controls. The echocardiographic characteristics of the study population are shown in Table 1 . The majority the patients (70%) had exertional dyspnea, on treatment for heart failure, mainly using angiotensin-converting enzyme inhibitors and beta-blockers ( Table 2 ).
Table 1

Echocardiographic characteristics of the study population

Variable *Chagas cardiomyopathy (n=20)Controls (n=15)p value
LV end-diastolic diameter (mm)68.4±9.246.6±4.2<0.001
LV end-systolic diameter (mm)56.1±10.830.1±3.7<0.001
LV end-diastolic volume (mL)204.8±79.493.0±32.6<0.001
LV end-systolic volume (mL)143.3±60.839.2±13.6<0.001
Stroke volume (mL)61.5±25.253.8±21.00.364
3D LV ejection fraction (%)29.8±7.557.7±6.1<0.001
QS (mL/s)- 360.3±147.5-305.6±126.00.231
QS/LV end-diastolic volume (s-1)1.80±0.403.28±0.64<0.001
QE (mL/s)270.4±135.3201.9±61.50.104
QA (mL/s)134.4±88.1109.1±37.80.623
QE/QA2.2±1.31.8±0.50.382
Mitral peak E velocity (m/s)81.0±30.281.9±19.50.921
Deceleration time (ms)166.5 (79)190.0 (38)0.290
Mitral peak A velocity (m/s)51.2±24.555.4±15.60.583
Mitral E/A ratio1.9±1.11.6±0.60.404
E/e’ ratio15.2±9.37.6±1.70.002

Data are expressed as mean±standard deviation, or median (interquartile range). LV: left ventricular; QS:peak instantaneous systolic flow; QE: peak flow during early left ventricular filling; QA: peak flow during atrial contraction.

Table 2

Medications used by the 20 patients with chronic dilated Chagas cardiomyopathy

MedicationsNumber of patients (%)
Diuretics19 (95)
Spironolactone5 (25)
Angiotensin-converting enzyme inhibitors16 (80)
Angiotensin receptor antagonists3 (15)
Digoxin13 (65)
Amiodarone6 (30)
Anticoagulant therapy8 (40)
Beta-blockers17 (85)
Aspirin1 (5)
Data are expressed as mean±standard deviation, or median (interquartile range). LV: left ventricular; QS:peak instantaneous systolic flow; QE: peak flow during early left ventricular filling; QA: peak flow during atrial contraction. Heart rate (beats per minute) was similar between the Chagas cardiomyopathy and the control group — 62.4±10.2 vs. 66.1± 11.0, p=0.3, respectively. The patients with CC had greater LV end-diastolic and end-systolic volumes, and lower LV ejection fraction, compared to the control group. However, stroke volume and maximum ejection flow during systole (QS) were similar between the groups. There was a strong correlation between QS and stroke volume: r=0.91, p<0.001. The CC group had a lower QS/LV end-diastolic volume ratio compared with the controls ( Figure 2 , D). The QS/LV end-diastolic volume ratio presented a strong correlation with the ejection fraction: r=0.89, p<0.001. Doppler evaluation of mitral velocity did not show any difference in E, A, E/A ratio and E wave deceleration time. As expected, the patients with CC showed an increase in preload compared with the control group, as demonstrated by an increased LV end-diastolic volume and E/e’ ratio. The maximum flow in the early and passive filling phase (QE) and during atrial contraction (QA) was similar between patients and controls.

Discussion

In our study, we evaluated the hemodynamic adaptations of the LV in CC using volume and flow curves by 3D echocardiography compared to a control group. Although the patients with CC had severe LV systolic function with ejection fraction of 30%, the stroke volumes were similar to controls. This discrepancy may be explained by the adaptive mechanisms that occur in chronic LV systolic dysfunction.[5 , 6] The ventricle with low ejection fraction but with increased end-diastolic volume ejects the same amount of blood as a ventricle with normal end-diastolic volume and ejection fraction.[7] This is due to preservation of the Frank-Starling mechanism in CC at rest, which is in agreement with the findings of Holubasch et al.[5] Three-dimensional echocardiography allows non-invasive preload measurement with high accuracy. End-diastolic LV volume is the best representation of preload, which expresses the degree of myocardial stretch before contraction. Limitations in evaluating accurately ventricular volume by standard echocardiographic methods lead to used ventricular filling pressures as a surrogate measurement of preload. However, the relationship between filling pressures and ventricular volume is not linear, depending on the compliance of left-sided cardiac chamber.[8] The volume-time curve by 3D echocardiography also provides information for calculating flow at any stage of the cardiac cycle. In our study, the flow was obtained by polynomial interpolation. Polynomial interpolation is an accurate low-complexity method that allows to measure the variation of any derivable curve. We recently used this tool to conduct a Covid-19 growth rate analysis.[9 , 10] Maximal ejection flow (QS) was similar between the groups, which did not reflect left ventricular systolic function. The strong correlation between absolute QS and stroke volume suggests that the same mechanism that normalized the Stroke volume competed for the normalization of QS. Therefore, QS/LV end-diastolic volume withdraws the effect of left ventricular dilatation, which is increased preload, and derive a variable that allows assessing LV global systolic function. Indeed, in our study, absolute QS/LV end-diastolic volume was lower in those patients who had CC than in normal controls, which is in agreement with the findings of other authors.[4 , 11 , 12] This artifice is the same used to calculate ejection fraction. By dividing the systolic volume (SV) by end-diastolic left ventricular volume, the result is more than a percentage of the final left ventricular volume that is ejected. The ratio represents the normalization of stroke volume by the representative of preload: LV end volume. Since preload is one of the determinants of systolic function, this may explain the prognostic importance of ejection fraction in cardiomyopathies. Similarly, Hammersmeister et al.[11] validated a method for assessing LV volume and flow in 1974, in several cardiovascular diseases, by cardiac catheterization.[11] Ventricular volume was calculated by ventriculography at a frequency of 60 frames/s, using the area-length method. The flow was obtained by the first derivative of the polynomial that approached the volume curve. However, this method is limited due to its invasive nature. On the other hand, in our study, we obtained the LV volume curve during the cardiac cycle with a frequency three times greater than a similar method described by Hammermeister et al.[11] In addition, we found a strong correlation between the polynomial and LV volume curve, allowing the calculation of flow with great accuracy. The absence of difference between diastolic flow values between groups was also observed by Hammermeister et al.[13] The “U” behavior of these variables considering diastolic function worsening explains these results, as observed by Ohno et al[6] in an experimental study.[6] Despite this, the E/e’ratio was higher in the group with CC than in the control group, which is in agreement with Oliveira et al.,[14] who observed that this variable was an independent predictor for elevated brain natriuretic peptide (BNP) levels in CC.[14] Three-dimensional echocardiography allows to revisit experimental studies from the beginning of the last century, when the Frank-Starling mechanism was described and the mechanical factors related to stroke volume, recognized at that time as a measure of cardiac function, were studied.[15] This study had the following limitations: left ventricular diastolic function was not classified, but the parameters to assess diastolic function were taken. The normal values for QS/LV end-diastolic volume was based on the controls, which may not be the reference values. Finally, the clinical importance and prognostic implications of these findings are not fully known yet. However, our objective was to demonstrate the hemodynamic adaptations present in Chagas cardiomyopathy using the measures of volume and flow obtained by the volume-time curve.

Conclusions

Our study shows that instantaneous systolic flow and stroke volume were similar between patients with severe ventricular dysfunction due to CC and healthy controls. Using a non-invasive tool for the first time in CC, we demonstrated that an increase in LV end-diastolic volume, which is a measure of ventricular preload, is the main adaptation mechanism that maintains the flow and stroke volumes in the setting of severe systolic dysfunction. QS/LV end-diastolic volume, in this study, was shown to be representative of left ventricular global systolic function, whose usefulness and prognostic value should be studied in later studies.
  13 in total

1.  On the mechanical factors which determine the output of the ventricles.

Authors:  S W Patterson; E H Starling
Journal:  J Physiol       Date:  1914-09-08       Impact factor: 5.182

Review 2.  Quantitative assessment of left ventricular systolic function using 3-dimensional echocardiography.

Authors:  Rahul Mehrotra; R Alagesan; Sameer Srivastava
Journal:  Indian Heart J       Date:  2013-09-23

3.  Existence of the Frank-Starling mechanism in the failing human heart. Investigations on the organ, tissue, and sarcomere levels.

Authors:  C Holubarsch; T Ruf; D J Goldstein; R C Ashton; W Nickl; B Pieske; K Pioch; J Lüdemann; S Wiesner; G Hasenfuss; H Posival; H Just; D Burkhoff
Journal:  Circulation       Date:  1996-08-15       Impact factor: 29.690

4.  The rate of change of left ventricular volume in man. I. Validation and peak systolic ejection rate in health and disease.

Authors:  K E Hammermeister; R C Brooks; J R Warbasse
Journal:  Circulation       Date:  1974-04       Impact factor: 29.690

5.  ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure 2012: The Task Force for the Diagnosis and Treatment of Acute and Chronic Heart Failure 2012 of the European Society of Cardiology. Developed in collaboration with the Heart Failure Association (HFA) of the ESC.

Authors:  John J V McMurray; Stamatis Adamopoulos; Stefan D Anker; Angelo Auricchio; Michael Böhm; Kenneth Dickstein; Volkmar Falk; Gerasimos Filippatos; Cândida Fonseca; Miguel Angel Gomez-Sanchez; Tiny Jaarsma; Lars Køber; Gregory Y H Lip; Aldo Pietro Maggioni; Alexander Parkhomenko; Burkert M Pieske; Bogdan A Popescu; Per K Rønnevik; Frans H Rutten; Juerg Schwitter; Petar Seferovic; Janina Stepinska; Pedro T Trindade; Adriaan A Voors; Faiez Zannad; Andreas Zeiher
Journal:  Eur Heart J       Date:  2012-05-19       Impact factor: 29.983

6.  Hemodynamic correlates for timing intervals, ejection rate and filling rate derived from the radionuclide angiographic volume curve.

Authors:  D J Magorien; P Shaffer; C Bush; R D Magorien; A J Kolibash; D V Unverferth; T M Bashore
Journal:  Am J Cardiol       Date:  1984-02-01       Impact factor: 2.778

7.  Correlation between BNP levels and Doppler echocardiographic parameters of left ventricle filling pressure in patients with Chagasic cardiomyopathy.

Authors:  Bráulio M R Oliveira; Fernando A Botoni; Antonio L P Ribeiro; Airandes S Pinto; Adelina M Reis; Maria do Carmo P Nunes; Manoel O C Rocha
Journal:  Echocardiography       Date:  2009-05       Impact factor: 1.724

Review 8.  Real-Time Three-Dimensional Echocardiography: Characterization of Cardiac Anatomy and Function-Current Clinical Applications and Literature Review Update.

Authors:  Omar Velasco; Morgan Q Beckett; Aaron W James; Megan N Loehr; Taylor G Lewis; Tahmin Hassan; Rajesh Janardhanan
Journal:  Biores Open Access       Date:  2017-03-01

9.  Covid-19 growth rate analysis: application of a low-complexity tool for understanding and comparing epidemic curves.

Authors:  Airandes de Sousa Pinto; Edval Gomes Dos Santos Júnior; Carlos Alberto Rodrigues; Paulo Cesar Mendes Nunes; Livia Almeida da Cruz; Matheus Gomes Reis Costa; Manoel Otávio da Costa Rocha
Journal:  Rev Soc Bras Med Trop       Date:  2020-07-06       Impact factor: 1.581

10.  COVID-19 epidemic curve in Brazil: a sum of multiple epidemics, whose inequality and population density in the states are correlated with growth rate and daily acceleration. An ecological study.

Authors:  Airandes de Sousa Pinto; Carlos Alberto Rodrigues; Carlito Lopes Nascimento Sobrinho; Lívia Almeida da Cruz; Edval Gomes Dos Santos Junior; Paulo Cesar Nunes; Matheus Gomes Reis Costa; Manoel Otávio da Costa Rocha
Journal:  Rev Soc Bras Med Trop       Date:  2022-02-25       Impact factor: 1.581

View more
  1 in total

1.  Is it Possible to Non-Invasively Study the Hemodynamic Adaptations of Chagas Cardiomyopathy by the Volume-Time Curve Using 3D Echocardiography?

Authors:  José Luiz Barros Pena
Journal:  Arq Bras Cardiol       Date:  2022-06-10       Impact factor: 2.667

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.