A dual-frequency applied potential tomography technique: computer simulations.

H Griffiths, A Ahmed.   

Abstract

Applied potential tomography has been discussed in relation to both static and dynamic imaging. We have investigated the feasibility of obtaining static images by measuring profiles at two frequencies of drive current to exploit the differing gradients of electrical conductivity with frequency for different tissues. This method has the advantages that no profile for the homogeneous medium is then needed, and the electrodes can be coupled directly to the skin. To demonstrate the principle, computer simulations have been carried out using published electrical parameters for mammalian tissues at frequencies of 100 and 150 kHz. The distribution of complex electric potentials was calculated by the successive over-relaxation method in two dimensions for an abdominal cross-section with 16 electrodes equally spaced around the surface. From the computed electrode potentials, images were reconstructed using a back-projection method (neglecting phase information). Liver and kidney appeared most distinctly on the image because of their comparatively large conductivity gradients. The perturbations in the electrode potential differences between the two frequencies had a mean value of 5%, requiring accurate measurement in a practical system, compared with 150% when the 100 kHz values were related to a simulation of homogeneous saline equal in conductivity to muscle. The perturbations could be increased by widening the separation of the frequencies. Static imaging using a dual-frequency technique appears to be feasible, but a more detailed consideration of the electrical properties of tissues is needed to determine the optimum choice of frequencies.

Entities:  

Mesh:

Year:  1987        PMID: 3568559     DOI: 10.1088/0143-0815/8/4a/014

Source DB:  PubMed          Journal:  Clin Phys Physiol Meas        ISSN: 0143-0815


  3 in total

1.  Two-frequency impedance plethysmograph: real and imaginary parts.

Authors:  A Lozano; J Rosell; R Pallás-Areny
Journal:  Med Biol Eng Comput       Date:  1990-01       Impact factor: 2.602

2.  Multi-frequency static imaging in electrical impedance tomography: Part 1. Instrumentation requirements.

Authors:  P J Riu; J Rosell; A Lozano; R Pallàs-Areny
Journal:  Med Biol Eng Comput       Date:  1995-11       Impact factor: 2.602

Review 3.  A Review on Electrical Impedance Tomography Spectroscopy.

Authors:  Juliana Padilha Leitzke; Hubert Zangl
Journal:  Sensors (Basel)       Date:  2020-09-10       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.