| Literature DB >> 35666570 |
David Scheinker1,2,3,4, Angela Gu3, Joshua Grossman3, Andrew Ward3, Oseas Ayerdi3, Daniel Miller3, Jeannine Leverenz2, Korey Hood1,4, Ming Yeh Lee2, David M Maahs1,4,5, Priya Prahalad1,4.
Abstract
BACKGROUND: The use of continuous glucose monitors (CGMs) is recommended as the standard of care by the American Diabetes Association for individuals with type 1 diabetes (T1D). Few hardware-agnostic, open-source, whole-population tools are available to facilitate the use of CGM data by clinicians such as physicians and certified diabetes educators.Entities:
Keywords: continuous glucose monitor; diabetes; personalized medicine; population health; telehealth
Year: 2022 PMID: 35666570 PMCID: PMC9210201 DOI: 10.2196/27284
Source DB: PubMed Journal: JMIR Diabetes ISSN: 2371-4379
Figure 1Initial and revised timely interventions for diabetes excellence (TIDE) interface. TBR: time below range; TIR: time in range.
Figure 2Workflow illustrated with examples of weekly and monthly cadence of data collection, data transfer, and provider review. CDCES: certified diabetes care and education specialists; CGM: continuous glucose monitor; EMR: electronic medical record; TIDE: timely interventions for diabetes excellence.
Outcomes including sensitivity identifying patients appropriate for asynchronous contact through the medical record and the reduction in the number of patients reviewed.
| Week of review | February 7, 2020 | February 14, 2020 | February 21, 2020 | February 28, 2020 | March 6, 2020 | March 13, 2020 | March 20, 2020 |
| Patients in study, N | 56 | 58 | 59 | 62 | 64 | 64 | 64 |
| Patients flagged by TIDEa, n | 29 | 29 | 36 | 39 | 39 | 37 | 36 |
| Patients reviewed, % | 52 | 50 | 61 | 63 | 61 | 58 | 56 |
| Reduction in patients reviewedb, % |
|
|
|
|
|
|
|
| True positive flagsc, % | 29 | 21 | 31 | 27 | 30 | 34 | 34 |
| True negative flagsd, % | 23 | 17 | 19 | 15 | 9 | 16 | 19 |
| False positive flagse, % | 23 | 33 | 36 | 40 | 39 | 33 | 31 |
| False negative flagsf, % | 2 | 0 | 0 | 0 | 0 | 0 | 2 |
| Insufficient CGMg data, % | 9 | 10 | 10 | 6 | 8 | 9 | 9 |
| Sensitivityb, % |
|
|
|
|
|
|
|
| Specificity, % | 50 | 34 | 34 | 26 | 19 | 32 | 38 |
| Positive predictive value, % | 55 | 39 | 46 | 40 | 43 | 51 | 52 |
| Negative predictive value, % | 93 | 100 | 100 | 100 | 100 | 100 | 92 |
aTIDE: timely interventions for diabetes excellence.
bPrimary objective (italicized).
cFlagged by TIDE and appropriate for asynchronous contact.
dNot flagged by TIDE and not appropriate for asynchronous contact.
eFlagged by TIDE and not appropriate for asynchronous contact.
fNot flagged by TIDE and appropriate for asynchronous contact.
gCGM: continuous glucose monitor.
Continuous glucose monitor (CGM) data in external data sets.
| Data set | Patients, n | CGM days, n (number per patient) | CGM weeks, n (number per patient), n | Days active, mean (SD) | Glucose (mg/dL), mean (SD) | Time in rangea (%), mean (SD) | Percentage of time hypoglycemicb, mean (SD) | Percentage of time extremely hypoglycemicc, mean (SD) |
| 1 | 85 | 21,236 (249.8) | 3372 (39.7) | 6.3 | 141.3 (21.3) | 74.2 (13.3) | 3.1 (2.4) | 2 (3.1) |
| 2 | 12 | 315 (26.2) | 63 (5.2) | 5 | 152.9 (23.3) | 66.4 (13.2) | 4 (3) | 1.7 (2.4) |
| 3 | 120 | 30,815 (256.8) | 4546 (37.9) | 6.8 | 158.3 (26.7) | 65.9 (16) | 2.1 (2.3) | 0.5 (0.9) |
| 4 | 225 | 48,805 (216.9) | 7670 (34.1) | 6.4 | 162.3 (24.1) | 62.1 (14.1) | 3 (2.6) | 0.9 (1.4) |
| 5 | 450 | 54,535 (121.2) | 11,936 (26.5) | 4.6 | 162.6 (28) | 62.4 (16.3) | 2.9 (3.1) | 1 (2.3) |
| 6 | 180 | 1682 (9.3) | 378 (2.1) | 4.4 | 176.6 (33.3) | 50.4 (15.6) | 3.6 (3.2) | 3.4 (4.3) |
| 7 | 219 | 10,025 (45.8) | 1727 (7.9) | 5.8 | 184.9 (44.4) | 45.1 (16.6) | 4.6 (3.8) | 3.7 (4.9) |
| 8 | 133 | 1310 (9.8) | 384 (2.9) | 3.4 | 207 (35.3) | 38.2 (14.2) | 2.9 (3.7) | 1.6 (3.6) |
aPercentage of readings that were 70 to 180 mg/dL.
bPercentage of readings <70 mg/dL.
cPercentage of readings <54 mg/dL.
Figure 3Frequency of generic and personalized flags in external cohorts.
Frequency of generic and personalized flags based on continuous glucose monitor data in external data sets.
| Data set | Patients, n | Patients with at least 4 weeks of data, n (%) | Glucose flags, n (flags per patient per week) | Time in range flagsa, n (flags per patient per week) | Patients with mean glucose or time in range flag every week, n (%) | |||
|
|
|
| Genericb | Personalizeda | Genericc | Personalizedd | Generic | Personalized |
| 1 | 85 | 78 (92) | 329 (0.1) | 725 (0.22) | 493 (0.15) | 493 (0.12) | 1 (1) | 0 (0) |
| 2 | 12 | 10 (83) | 13 (0.22) | 14 (0.24) | 19 (0.33) | 19 (0.16) | 1 (10) | 0 (0) |
| 3 | 120 | 120 (100) | 1417 (0.31) | 1128 (0.25) | 1535 (0.34) | 1535 (0.15) | 4 (3.3) | 0 (0) |
| 4 | 225 | 225 (100) | 2595 (0.34) | 2002 (0.26) | 3204 (0.42) | 3204 (0.16) | 9 (4) | 0 (0) |
| 5 | 450 | 436 (97) | 4137 (0.35) | 3498 (0.29) | 4895 (0.41) | 4895 (0.21) | 31 (7.1) | 0 (0) |
| 6 | 180 | 4 (2) | 6 (0.38) | 4 (0.25) | 9 (0.56) | 9 (0.19) | 1 (25) | 0 (0) |
| 7 | 219 | 195 (89) | 967 (0.58) | 525 (0.31) | 1360 (0.81) | 1360 (0.18) | 97 (49.7) | 0 (0) |
| 8 | 133 | 32 (24) | 116 (0.84) | 47 (0.34) | 131 (0.95) | 131 (0.22) | 26 (81.3) | 1 (3.1) |
aPersonalized mean glucose (MG) flag triggered when MG>MG+10 mg/dL in baseline period.
bGeneric mean glucose flag triggered when mean bigeneric glucose >170 mg/dL.
cGeneric time in range flag triggered when the percentage of readings of 70-180 mg/dL was <60%.
dPersonalized time in range (TIR) flag triggered when TIR