Literature DB >> 35665911

Guaiac-based faecal occult blood tests versus faecal immunochemical tests for colorectal cancer screening in average-risk individuals.

Esmée J Grobbee1, Pieter Ha Wisse1, Eline H Schreuders1, Aafke van Roon2, Leonie van Dam1, Ann G Zauber3, Iris Lansdorp-Vogelaar4, Wichor Bramer5, Sarah Berhane6, Jonathan J Deeks6, Ewout W Steyerberg4, Monique E van Leerdam1, Manon Cw Spaander1, Ernst J Kuipers1.   

Abstract

BACKGROUND: Worldwide, many countries have adopted colorectal cancer (CRC) screening programmes, often based on faecal occult blood tests (FOBTs). CRC screening aims to detect advanced neoplasia (AN), which is defined as CRC or advanced adenomas. FOBTs fall into two categories based on detection technique and the detected blood component: qualitative guaiac-based FOBTs (gFOBTs) and faecal immunochemical tests (FITs), which can be qualitative and quantitative. Screening with gFOBTs reduces CRC-related mortality.
OBJECTIVES: To compare the diagnostic test accuracy of gFOBT and FIT screening for detecting advanced colorectal neoplasia in average-risk individuals. SEARCH
METHODS: We searched CENTRAL, MEDLINE, Embase, BIOSIS Citation Index, Science Citation Index Expanded, and Google Scholar. We searched the reference lists and PubMed-related articles of included studies to identify additional studies. SELECTION CRITERIA: We included prospective and retrospective studies that provided the number of true positives, false positives, false negatives, and true negatives for gFOBTs, FITs, or both, with colonoscopy as reference standard. We excluded case-control studies. We included studies in which all participants underwent both index test and reference standard ("reference standard: all"), and studies in which only participants with a positive index test underwent the reference standard while participants with a negative test were followed for at least one year for development of interval carcinomas ("reference standard: positive"). The target population consisted of asymptomatic, average-risk individuals undergoing CRC screening. The target conditions were CRC and advanced neoplasia (advanced adenomas and CRC combined). DATA COLLECTION AND ANALYSIS: Two review authors independently screened and selected studies for inclusion. In case of disagreement, a third review author made the final decision. We used the Rutter and Gatsonis hierarchical summary receiver operating characteristic model to explore differences between tests and identify potential sources of heterogeneity, and the bivariate hierarchical model to estimate sensitivity and specificity at common thresholds: 10 µg haemoglobin (Hb)/g faeces and 20 µg Hb/g faeces. We performed indirect comparisons of the accuracy of the two tests and direct comparisons when both index tests were evaluated in the same population. MAIN
RESULTS: We ran the initial search on 25 June 2019, which yielded 63 studies for inclusion. We ran a top-up search on 14 September 2021, which yielded one potentially eligible study, currently awaiting classification. We included a total of 33 "reference standard: all" published articles involving 104,640 participants. Six studies evaluated only gFOBTs, 23 studies evaluated only FITs, and four studies included both gFOBTs and FITs. The cut-off for positivity of FITs varied between 2.4 μg and 50 µg Hb/g faeces. For each Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 domain, we assessed risk of bias as high in less than 20% of studies. The summary curve showed that FITs had a higher discriminative ability than gFOBTs for AN (P < 0.001) and CRC (P = 0.004). For the detection of AN, the summary sensitivity of gFOBTs was 15% (95% confidence interval (CI) 12% to 20%), which was significantly lower than FITs at both 10 μg and 20 μg Hb/g cut-offs with summary sensitivities of 33% (95% CI 27% to 40%; P < 0.001) and 26% (95% CI 21% to 31%, P = 0.002), respectively. Results were simulated in a hypothetical cohort of 10,000 screening participants with 1% CRC prevalence and 10% AN prevalence. Out of 1000 participants with AN, gFOBTs missed 850, while FITs missed 670 (10 μg Hb/g cut-off) and 740 (20 μg Hb/g cut-off). No significant differences in summary specificity for AN detection were found between gFOBTs (94%; 95% CI 92% to 96%), and FITs at 10 μg Hb/g cut-off (93%; 95% CI 90% to 95%) and at 20 μg Hb/g cut-off (97%; 95% CI 95% to 98%). So, among 9000 participants without AN, 540 were offered (unnecessary) colonoscopy with gFOBTs compared to 630 (10 μg Hb/g) and 270 (20 μg Hb/g) with FITs. Similarly, for the detection of CRC, the summary sensitivity of gFOBTs, 39% (95% CI 25% to 55%), was significantly lower than FITs at 10 μg and 20 μg Hb/g cut-offs: 76% (95% CI 57% to 88%: P = 0.001) and 65% (95% CI 46% to 80%; P = 0.035), respectively. So, out of 100 participants with CRC, gFOBTs missed 61, and FITs missed 24 (10 μg Hb/g) and 35 (20 μg Hb/g). No significant differences in summary specificity for CRC were found between gFOBTs (94%; 95% CI 91% to 96%), and FITs at the 10 μg Hb/g cut-off (94%; 95% CI 87% to 97%) and 20 μg Hb/g cut-off (96%; 95% CI 91% to 98%). So, out of 9900 participants without CRC, 594 were offered (unnecessary) colonoscopy with gFOBTs versus 594 (10 μg Hb/g) and 396 (20 μg Hb/g) with FITs. In five studies that compared FITs and gFOBTs in the same population, FITs showed a higher discriminative ability for AN than gFOBTs (P = 0.003). We included a total of 30 "reference standard: positive" studies involving 3,664,934 participants. Of these, eight were gFOBT-only studies, 18 were FIT-only studies, and four studies combined both gFOBTs and FITs. The cut-off for positivity of FITs varied between 5 µg to 250 µg Hb/g faeces. For each QUADAS-2 domain, we assessed risk of bias as high in less than 20% of studies. The summary curve showed that FITs had a higher discriminative ability for detecting CRC than gFOBTs (P < 0.001). The summary sensitivity for CRC of gFOBTs, 59% (95% CI 55% to 64%), was significantly lower than FITs at the 10 μg Hb/g cut-off, 89% (95% CI 80% to 95%; P < 0.001) and the 20 μg Hb/g cut-off, 89% (95% CI 85% to 92%; P < 0.001). So, in the hypothetical cohort with 100 participants with CRC, gFOBTs missed 41, while FITs missed 11 (10 μg Hb/g) and 11 (20 μg Hb/g). The summary specificity of gFOBTs was 98% (95% CI 98% to 99%), which was higher than FITs at both 10 μg and 20 μg Hb/g cut-offs: 94% (95% CI 92% to 95%; P < 0.001) and 95% (95% CI 94% to 96%; P < 0.001), respectively. So, out of 9900 participants without CRC, 198 were offered (unnecessary) colonoscopy with gFOBTs compared to 594 (10 μg Hb/g) and 495 (20 μg Hb/g) with FITs. At a specificity of 90% and 95%, FITs had a higher sensitivity than gFOBTs. AUTHORS'
CONCLUSIONS: FITs are superior to gFOBTs in detecting AN and CRC in average-risk individuals. Specificity of both tests was similar in "reference standard: all" studies, whereas specificity was significantly higher for gFOBTs than FITs in "reference standard: positive" studies. However, at pre-specified specificities, the sensitivity of FITs was significantly higher than gFOBTs.
Copyright © 2022 The Cochrane Collaboration. Published by John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2022        PMID: 35665911      PMCID: PMC9169237          DOI: 10.1002/14651858.CD009276.pub2

Source DB:  PubMed          Journal:  Cochrane Database Syst Rev        ISSN: 1361-6137


  147 in total

1.  The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed.

Authors:  Jonathan J Deeks; Petra Macaskill; Les Irwig
Journal:  J Clin Epidemiol       Date:  2005-09       Impact factor: 6.437

Review 2.  Colorectal cancer screening: a global overview of existing programmes.

Authors:  Eline H Schreuders; Arlinda Ruco; Linda Rabeneck; Robert E Schoen; Joseph J Y Sung; Graeme P Young; Ernst J Kuipers
Journal:  Gut       Date:  2015-06-03       Impact factor: 23.059

3.  Evaluation of a desk top instrument for the automated development and immunochemical quantification of fecal occult blood.

Authors:  Paul Rozen; Amal Waked; Alex Vilkin; Zohar Levi; Yaron Niv
Journal:  Med Sci Monit       Date:  2006-05-29

4.  Choice of fecal occult blood tests for colorectal cancer screening: recommendations based on performance characteristics in population studies: a WHO (World Health Organization) and OMED (World Organization for Digestive Endoscopy) report.

Authors:  Graeme P Young; D James B St John; Sidney J Winawer; Paul Rozen
Journal:  Am J Gastroenterol       Date:  2002-10       Impact factor: 10.864

5.  A higher detection rate for colorectal cancer and advanced adenomatous polyp for screening with immunochemical fecal occult blood test than guaiac fecal occult blood test, despite lower compliance rate. A prospective, controlled, feasibility study.

Authors:  Zohar Levi; Shlomo Birkenfeld; Alex Vilkin; Micha Bar-Chana; Irena Lifshitz; Miri Chared; Eran Maoz; Yaron Niv
Journal:  Int J Cancer       Date:  2011-05-15       Impact factor: 7.396

6.  Randomised study of screening for colorectal cancer with faecal-occult-blood test.

Authors:  O Kronborg; C Fenger; J Olsen; O D Jørgensen; O Søndergaard
Journal:  Lancet       Date:  1996-11-30       Impact factor: 79.321

7.  Long-term mortality after screening for colorectal cancer.

Authors:  Aasma Shaukat; Steven J Mongin; Mindy S Geisser; Frank A Lederle; John H Bond; Jack S Mandel; Timothy R Church
Journal:  N Engl J Med       Date:  2013-09-19       Impact factor: 91.245

8.  Colonoscopy-controlled intra-individual comparisons to screen relevant neoplasia: faecal immunochemical test vs. guaiac-based faecal occult blood test.

Authors:  F A Oort; J S Terhaar Sive Droste; R W M Van Der Hulst; H A Van Heukelem; R J L F Loffeld; I C E Wesdorp; R L J Van Wanrooij; L De Baaij; E R Mutsaers; S van der Reijt; V M H Coupe; J Berkhof; A A Bouman; G A Meijer; C J J Mulder
Journal:  Aliment Pharmacol Ther       Date:  2009-10-29       Impact factor: 8.171

9.  QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies.

Authors:  Penny F Whiting; Anne W S Rutjes; Marie E Westwood; Susan Mallett; Jonathan J Deeks; Johannes B Reitsma; Mariska M G Leeflang; Jonathan A C Sterne; Patrick M M Bossuyt
Journal:  Ann Intern Med       Date:  2011-10-18       Impact factor: 25.391

10.  Fecal immunochemical test for colorectal cancer from a prospective cohort with 513,283 individuals: Providing detailed number needed to scope (NNS) before colonoscopy.

Authors:  Chien Hua Chen; Chi Pang Wen; Min Kuang Tsai
Journal:  Medicine (Baltimore)       Date:  2016-09       Impact factor: 1.889

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.