Marco Giurgiu1,2, Simon Kolb1, Carina Nigg1,3, Alexander Burchartz1, Irina Timm1, Marlissa Becker4, Ellen Rulf1, Ann-Kathrin Doster1, Elena Koch1, Johannes B J Bussmann5, Claudio Nigg6, Ulrich W Ebner-Priemer2,7, Alexander Woll1.
Abstract
Objectives: Studies that assess all three dimensions of the integrative 24-hour physical behaviour (PB) construct, namely, intensity, posture/activity type and biological state, are on the rise. However, reviews on validation studies that cover intensity, posture/activity type and biological state assessed via wearables are missing. Design: Systematic review. The risk of bias was evaluated by using the QUADAS-2 tool with nine signalling questions separated into four domains (ie, patient selection/study design, index measure, criterion measure, flow and time). Data sources: Peer-reviewed validation studies from electronic databases as well as backward and forward citation searches (1970-July 2021). Eligibility criteria for selecting studies: Wearable validation studies with children and adolescents (age <18 years). Required indicators: (1) study protocol must include real-life conditions; (2) validated device outcome must belong to one dimension of the 24-hour PB construct; (3) the study protocol must include a criterion measure; (4) study results must be published in peer-reviewed English language journals.Entities:
Keywords: accelerometer; physical activity; sedentary; sleep; validation
Year: 2022 PMID: 35646389 PMCID: PMC9109110 DOI: 10.1136/bmjsem-2021-001267
Source DB: PubMed Journal: BMJ Open Sport Exerc Med ISSN: 2055-7647
Figure 1Preferred Reporting Items for Systematic Reviews and Meta-Analyses flowchart illustrating the literature search and screening process.
Summary of data extraction: participant and study characteristics
| Category | Total (N=76) | Biological state (n=12) | Posture/activity type (n=12) | Intensity (n=52) | |
| Publication year | ≤1999 | 4 | 1 | 3 | |
| 2000–2010 | 18 | 1 | 17 | ||
| ≥2011 | 54 | 11 | 11 | 32 | |
| Study location | Africa | 1 | 1 | ||
| Asia | 7 | 1 | 1 | 5 | |
| Europe | 29 | 1 | 8 | 20 | |
| North America | 31 | 9 | 1 | 21 | |
| Australia/Oceania | 7 | 1 | 2 | 4 | |
| South America | 1 | 1 | |||
| Participants (N)* | ≤19 | 14 | 2 | 3 | 9 |
| 20–50 | 46 | 9 | 8 | 29 | |
| ≥51 | 17 | 1 | 1 | 15 | |
| Mean age (years)† | 0–3.9 | 12 | 4 | 2 | 6 |
| 4.0–7.9 | 16 | 1 | 3 | 12 | |
| 8.0–12.9 | 37 | 6 | 5 | 26 | |
| 13–18 | 9 | 2 | 7 | ||
| Sex (%, female)‡ | 0–25 | 3 | 1 | 2 | |
| 26–74 | 68 | 12 | 9 | 47 | |
| 75–100 | 2 | 2 | |||
| Measurement duration (days) | ≤1 | 34 | 7 | 7 | 20 |
| 2–6 | 15 | 2 | 2 | 11 | |
| ≥7 | 27 | 3 | 3 | 21 | |
| Criterion measure | Doubly labelled water | 14 | 14 | ||
| Heart telemetry | 1 | 1 | |||
| Indirect calorimetry | 4 | 4 | |||
| Observation (direct) | 11 | 11 | |||
| Observation (video) | 11 | 2 | 8 | 1 | |
| Polysomnography | 6 | 6 | |||
| Questionnaire/diary | 3 | 2 | 1 | ||
| Wearable | 26 | 2 | 4 | 20 | |
| Statistical analyses | Epoch-by-epoch | 14 | 6 | 3 | 5 |
| Person/study level | 67 | 8 | 8 | 51 | |
*One article reported two studies and was counted twice.
†One study reported two subgroups, and the subgroups were counted twice; three studies were not included in the summary statistics due to the lack of age information.
‡Three studies were not included in the summary statistics due to the lack of sex information.
Summary of data extraction: wearables
| Category | Total (N=76) | Biological state (n=12) | Posture/activity type (n=12) | Intensity (n=52) | |
| Type | Uniaxial accelerometer | 33 | 5 | 2 | 26 |
| Biaxial accelerometer | 8 | 3 | 5 | ||
| Triaxial accelerometer | 47 | 5 | 14 | 28 | |
| Pedometer | 9 | 9 | |||
| Outcome | Sleep time | 8 | 8 | ||
| Sleep–wake metrics | 4 | 4 | |||
| Different postures/types | 8 | 8 | |||
| Time in SB | 16 | 4 | 12 | ||
| Time in LPA | 10 | 10 | |||
| Time in MVPA | 19 | 19 | |||
| Energy expenditure | 21 | 21 | |||
| Steps | 16 | 16 | |||
| Counts | 10 | 1 | 9 | ||
| Wear position*† | Ankle | 5 | 4 | 1 | |
| Chest | 2 | 2 | |||
| Hip/waist | 55 | 5 | 7 | 43 | |
| Lower back | 2 | 2 | |||
| Thigh | 4 | 4 | |||
| Upper arm | 5 | 5 | |||
| Wrist | 30 | 9 | 7 | 14 | |
| Backpack/pockets | 3 | 2 | 1 | ||
*One study did not report any information about the sensor wearing position.
†If studies included multiple devices or different wearing positions, we counted each wearing position.
Criteria for the risk of bias assessment and the percentage of studies meeting these criteria
| Criteria items | Studies meeting criterion (N) | |||
| Total | Biological state (n=12) | Posture/activity type (n=12) | Intensity (n=52) | |
| Domain 1: patient selection/study design | ||||
| 1. Was the study conducted in different free-living settings (eg, school or home)?* | 43 (67.2%) | NA | 7 (58.3%) | 36 (69.2%) |
| 2. Did the study take place for at least 2 days? | 42 (55.3%) | 5 (41.6%) | 5 (41.6%) | 32 (61.5%) |
| 3. Did the study provide any information about the inclusion/exclusion of the recruiting process? | 45 (59.2%) | 5 (41.6%) | 3 (25%) | 37 (71.2%) |
| 4. Did the study include at least a sample of 20 participants? | 62 (81.6%) | 10 (83.3%) | 9 (75%) | 43 (82.7%) |
| Domain 2: index measure | ||||
| 5. Was the algorithm of the validated outcome reported (ie, formula) or at least further information cited? | 34 (44.7%) | 9 (75%) | 7 (58.3%) | 18 (34.6%) |
| 6. Did the participants wear the wearable for at least 8 hours per day?* | 46 (60.5%) | NA | 4 (33.3%) | 32 (61.5%) |
| Domain 3: criterion measure | ||||
| 7. Is the selected reference the gold standard? | 35 (46.1%) | 8 (66.6%) | 8 (66.6%) | 19 (36.5%) |
| Domain 4: flow and timing | ||||
| 8. Did they provide any information about data synchronisation?† | 39 (51.3%) | 8 (80%) | 9 (75%) | 20 (54.1%) |
| 9. Were all participants included in the analyses or any exclusion reasons provided? | 70 (92.1%) | 10 (83.3%) | 11 (91.7%) | 49 (94.2%) |
*Only relevant for n=64 studies.
†Only relevant for n=59 studies.
NA, not applicable.
Figure 2Overall risk of bias classification separated by different dimensions of the 24-hour physical behaviour construct. The number within the circles represents the study number, as listed in the full data extraction (see online supplemental appendices 5 and 8). Studies with a green circle were evaluated as ‘low risk’; the orange circle represents ‘some concerns’; and red circles represent ‘high risk’.
Validity of wearables separated by dimensions and age groups
| Wearable | Early years (infants, preschoolers; <6 years) | School-aged children (6–12 years) | Adolescents (≥13 years) | |||||||
| Bio | Pos/AT | Int | Bio | Pos/AT | Int | Bio | Pos/AT† | Int‡ | ||
| Uniaxial accelerometer | Actical |
| ||||||||
| ActiGraph AM7164 | ||||||||||
| ActiGraph GT1M | ↓ |
|
|
|
| |||||
| Actimaker EW4800P |
| |||||||||
| ActiTrainer |
| |||||||||
| Actiwatch activity monitor |
| |||||||||
| Actiwatch spectrum |
|
| ||||||||
| Actiwatch-L |
|
| ||||||||
| Actiwatch 64 | ↓ | |||||||||
| Caltrac | ||||||||||
| CSA Accelerometer | ||||||||||
| Motionlogger Sleepwatch |
| |||||||||
| New Lifestyle 1000 | ||||||||||
| Omron HJ-151 |
| |||||||||
| Polar Active Watch |
| |||||||||
| Biaxial accelerometer | Actiwatch-2 |
|
| |||||||
| Omron HJ-720IT-E2 |
| |||||||||
| SenseWear Pro2 |
| |||||||||
| SenseWear Pro3 |
| ↓ | ||||||||
| Triaxial accelerometer | 3dNX model v2 |
| ||||||||
| 3dNX model v3 |
| |||||||||
| ActiGraph GT3X |
| |||||||||
| ActiGraph GT3X+ |
|
| ↓ | |||||||
| ActiGraph GT9X | ||||||||||
| Actiheart |
|
| ||||||||
| ActivPAL | ||||||||||
| Axivity AX3 |
| |||||||||
| Dynaport ADL Monitor |
| |||||||||
| Fitbit Charge HR |
|
| ||||||||
| Fitbit Flex |
| |||||||||
| Fitbit Zip | ||||||||||
| Garmin Vivofit 1 |
| |||||||||
| GENEActiv |
| |||||||||
| Kenz Lifecorder |
| |||||||||
| MovBand Model 2 |
| |||||||||
| Omron HJA-350IT |
| |||||||||
| Polar Loop | ↓ | |||||||||
| RT3 |
| |||||||||
| SCA3000 |
| |||||||||
| SenseWear Mini |
| |||||||||
| Sqord |
| |||||||||
| Tracmor2 |
| |||||||||
| TracmorD |
| |||||||||
| Tritrac-R3D | ||||||||||
| Wristband |
| |||||||||
| Yamasa EX-200 |
| |||||||||
| Zamzee |
| |||||||||
| Accelerometer | Polar A370 |
|
| |||||||
| Pedometer | Walk4Life MVP | |||||||||
| Yamax Digi-Walker SW-200 | ||||||||||
| Yamax Digi-Walker SW-701 |
| |||||||||
↑ denotes moderate to strong validity; ↔ indicates mixed validity; ↓ indicates poor/weak validity.
bio., biological state; int, intensity; Pos/AT, posture/activity type.