| Literature DB >> 35621541 |
Jan D'haese1, Carine Matthys2, Hamed Sahak1, Jos Besseler3, Hugo De Bruyn1,2.
Abstract
Denture wearers often complain about jeopardized function and reduced quality of life due to lack of prosthesis' retention. Implant-retained mandibular overdentures, on two non-connected implants (2IOD) are well-proven solutions to overcome these issues. We prospectively assessed 69 patients and scrutinized clinical records until at least seven years of function. Thirty-six were retained on Locator® Abutments (LA) and thirty-tree on Ball Abutments (BA). Both systems were compared regarding the type, amount, and total cost of required maintenance. One implant was lost, yielding 98.7% survival after seven years. In total, 438 technical issues occurred: 121 (27.35%) in BA and 317 (72.4%) in LA. Out of these, 343 events (78%) were solved chairside: 191 (43.6%) were replacements of retention caps, 113 (25.8%) were minor acrylic repairs, 26 (5.9%) pressure ulcers had to be relieved, and 13 (3%) were related to abutments. LA required 179 insert replacements compared to 12 in the BA group. The overall initial treatment cost was EUR 3850 (base year of the analysis: 2003). The average total maintenance cost in relation to the initial cost for the LA and BA groups was 19.11 (range 0-82.24%) and 18.91% (range 0-113.26%) respectively (p = 0.540). Conclusions: The seven-year maintenance costs for a 2IOD is acceptable when the patient is regularly checked and professionally maintained. Most events are easily solvable chairside, but a few patients required more expensive interventions, regardless of the type of attachment used.Entities:
Keywords: edentulism; maintenance cost; mandibular overdentures; patient related outcome measurements; quality of life
Year: 2022 PMID: 35621541 PMCID: PMC9139480 DOI: 10.3390/dj10050088
Source DB: PubMed Journal: Dent J (Basel) ISSN: 2304-6767
Figure 1Radiographical and clinical example an overdenture retained on 2 non-connected implants on either 2 ball abutments (left) or 2 locator abutments (right).
Figure 2Decision tree used to select the cases to be assessed.
Overview of the different treatment groups regarding distribution, age, and smoking habits.
| Group 2: Ball Abutment | Group 1: Locator Abutment | |
|---|---|---|
| Total number of patients | 36 (20/16) | 33 (21/12) |
| Age at implant insertion | 65 (49-80) | 64 (46-83) |
| Number of smokers | 7 | 3 |
Detailed specification of all maintenance issues and repairs between the different treatment groups (B = Ball, L = Locator) up to 7 year after implant insertion.
| Minor Acrylic Repairs | Rebasing Overdenture | Mucosal Pressure Ulcera | Retention Issues | Abutment Loosening | Abutment Replacement | Overdenture Cleaning | Overdenture Replacement | Total | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| B | L | B | L | B | L | B | L | B | L | B | L | B | L | B | L | ||
| Year | 6 | 2 | 8 | 4 | 4 | 0 | 10 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 34 |
| Year | 7 | 8 | 8 | 7 | 4 | 2 | 3 | 3 | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 0 | 43 |
| Year | 8 | 14 | 5 | 4 | 3 | 0 | 27 | 3 | 0 | 0 | 1 | 1 | 0 | 0 | 0 | 2 | 68 |
| Year | 8 | 9 | 2 | 6 | 1 | 0 | 21 | 1 | 1 | 1 | 1 | 0 | 0 | 0 | 0 | 0 | 51 |
| Year | 11 | 9 | 6 | 5 | 4 | 1 | 32 | 1 | 0 | 0 | 0 | 0 | 1 | 1 | 3 | 0 | 74 |
| Year | 10 | 8 | 5 | 9 | 2 | 1 | 40 | 1 | 0 | 0 | 3 | 0 | 2 | 0 | 0 | 3 | 84 |
| Year | 10 | 3 | 3 | 5 | 3 | 1 | 46 | 3 | 0 | 0 | 4 | 1 | 0 | 0 | 3 | 2 | 84 |
| Total | 60 | 53 | 37 | 40 | 21 | 5 | 179 | 12 | 1 | 1 | 9 | 2 | 4 | 1 | 6 | 7 | 438 |
Figure 3Cumulative amount of maintenance costs in relation to the initial treatment costs. No significant difference observed between both treatment groups (p = 0.540). * and o represent the outliners.
Figure 4Maintenance costs up to seven years in function in relation to the initial treatment cost for both treatment groups. * and o represent the outliners.
Figure 5Cumulative percentage of maintenance costs compared to the initial treatment cost. For 50% of the total population, the amount of total maintenance cost is around 10% compared to the initial cost.