Literature DB >> 31264259

Five-year study of mandibular overdentures on stud abutments: Clinical outcome, patient satisfaction and prosthetic maintenance-Influence of bone resorption and implant position.

Carine Matthys1, Stijn Vervaeke2, Jos Besseler3, Hugo De Bruyn4,5.   

Abstract

OBJECTIVES: This prospective study analyses the 5-year clinical outcome, patient satisfaction and the technical outcome of a 2-implant overdenture on stud abutments. In addition, the influence of mandibular resorption and implant position on these outcomes was assessed.
MATERIAL AND METHODS: Patients received two implants in a one-stage delayed protocol. Final prosthesis on stud abutments was finalized after 3 months. Implant survival, bone loss, plaque and sulcus bleeding index, OHIP-14, technical outcome and costs were assessed after 5 years. The Cawood-Howell classification defined the mandibular resorption. Inter-implant distances and angles (frontal, sagittal) were digitally measured. The significance level was p < .05.
RESULTS: Fifty-six patients, 23 female and 33 males (mean age = 66.3, range 41-82), completed the follow-up. No implants were lost. Radiographical crestal bone loss was on average 1.25 mm (standard deviation SD 1.06), bleeding index was 0.75 (SD 0.73), and plaque index was 1.15 (SD 0.75) and higher for low mandibles (p = .001). The OHIP-14 reduction post-connection and after 5 years was significant (p < .001). Five-year maintenance required on average 6.7 (SD 4.8, range 0-25) interventions per patient. A larger inter-implant distance was associated with fewer replacement of retention inserts (p = .034) and less interventions (p = .006). Larger frontal (p = .023) and sagittal (p = .046) inter-implant angles (non-parallelism) required more inserts. The maintenance cost negatively influences the patient satisfaction (p = .004). 83% of the stud abutments showed wear.
CONCLUSION: The implant overdenture on cylindrical stud abutments is a good and stable solution, irrespective of the resorption profile of the mandible. OHIP-14 improved permanently up to 5 years but is negatively influenced by complication cost. A small inter-implant distance, more frontal, sagittal inter-implant divergence increased maintenance.
© 2019 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  dental implants; implant position; maintenance; mandibular overdenture; patient outcome assessment

Mesh:

Substances:

Year:  2019        PMID: 31264259     DOI: 10.1111/clr.13501

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  2 in total

1.  Implant-Retained Mandibular Overdentures: Patient-Related Outcome Measurements after Seven Years of Function.

Authors:  Jan D'haese; Carine Matthys; Hamed Sahak; Jos Besseler; Hugo De Bruyn
Journal:  Dent J (Basel)       Date:  2022-05-16

Review 2.  Lateral Alveolar Ridge Augmentation with an Autogenous Bone Block Graft Alone with or without Barrier Membrane Coverage: a Systematic Review and Meta-Analysis.

Authors:  Romario Gorgis; Lianna Qazo; Niels Henrik Bruun; Thomas Starch-Jensen
Journal:  J Oral Maxillofac Res       Date:  2021-09-30
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.