Objective: To compare the clinical value of contrast-enhanced ultrasound and conventional ultrasound-guided puncture biopsy in peripulmonary lesions of different sizes. Materials andEntities:
Mesh:
Year: 2022 PMID: 35615730 PMCID: PMC9110189 DOI: 10.1155/2022/6425145
Source DB: PubMed Journal: Contrast Media Mol Imaging ISSN: 1555-4309 Impact factor: 3.009
Figure 1A patient in the conventional ultrasound group, male, 56 years old. (a) Ultrasonography showed a hypoechoic mass in the middle lobe of the right lung, with a size of 51 mm∗38 mm, and the echo was still uniform. (b) Color Doppler displayed a little blood flow signal. (c) The needle was passed through the pleura, into the lesion, and cut for biopsy. (d) Five minutes after needle extraction, no obvious bleeding and pneumothorax and other complications were found.
Figure 2A patient in the contrast-enhanced ultrasound group. (a) Ultrasound examination showed a hypoechoic mass in the lower left lung, 43 mm ∗40 mm in size, with an uneven echo. (b) After injection of the contrast agent, it showed uneven enhancement. (c) The puncture needle was passed through the pleura, into the lesion, and cut for biopsy. (d) Five minutes after needle extraction, no obvious bleeding and pneumothorax and other complications were found.
Basic information of the conventional ultrasound group and contrast-enhanced ultrasound group.
| Group | Age | Maximum diameter | Location (lung) | Sexuality | ||
| Upper middle lobe | Lower lobe | Male | Female | |||
| Conventional ultrasound group | 68.7 ± 14.0 | 45.4 ± 22.4 | 38 | 17 | 35 | 20 |
| Contrast-enhanced ultrasound group | 67.8 ± 13.3 | 51.0 ± 26.5 | 42 | 13 | 38 | 17 |
| c2 value/ | 0.427 | 1.201 | 0.733 | 0.367 | ||
|
| 0.67 | 0.23 | 0.39 | 0.55 | ||
|
| ||||||
| Group | Success rate of single puncture | Success rate of puncture | Pneumothorax rate | |||
| Conventional ultrasound group | 72.7% (40/55) | 80.0% (44/55) | 16.4% (9/55) | |||
| Contrast-enhanced ultrasound group | 90.9% (50/55) | 94.6% (52/55) | 10.9% (6/55) | |||
|
| 6.111 | 4.01 | 0.695 | |||
|
| 0.013 | 0.045 | 0.405 | |||
Related indicators of biopsy for the <30 mm group.
| Group | Success rate of single puncture | Success rate of puncture | Needle bleeding rate | Pneumothorax rate |
|---|---|---|---|---|
| Conventional ultrasound group | 77.8% (14/18) | 83.3% (15/18) | 27.8% (5/18) | 27.8% (5/18) |
| Contrast-enhanced ultrasound group | 80.0% (16/20) | 90.0% (18/20) | 25.0% (5/20) | 20.0% (4/20) |
|
| 0.027 | 0.016 | 0.037 | 0.309 |
|
| 0.869 | 0.899 | 0.848 | 0.578 |
Related indicators of biopsy for the ≥30 mm group.
| Group | Success rate of single puncture | Success rate of puncture | Needle bleeding rate | Pneumothorax rate |
|---|---|---|---|---|
| Conventional ultrasound group | 70.3% (26/37) | 78.4% (29/37) | 10.8% (4/37) | 10.8% (4/37) |
| Contrast-enhanced ultrasound group | 97.1% (34/35) | 97.1% (34/35) | 2.9% (1/35) | 5.7% (2/35) |
|
| 7.517 | 4.202 | 0.745 | 0.126 |
|
| 0.006 | 0.04 | 0.388 | 0.722 |