Literature DB >> 29525458

Ultrasound-Guided Percutaneous Needle Biopsy for Peripheral Pulmonary Lesions: Diagnostic Accuracy and Influencing Factors.

Yu-Qing Guo1, Xin-Hong Liao1, Zhi-Xian Li2, Yuan-Yuan Chen1, Si-Da Wang1, Ji-Han Wang1, Xian-Shan Liao1, Yuan Luo1.   

Abstract

A retrospective study was carried out to evaluate the diagnostic accuracy and the factors influencing the diagnostic accuracy of 648 procedures of ultrasound-guided percutaneous needle biopsy (PNB) for peripheral pulmonary lesions (PPLs). We reviewed the histopathology results, the clinical records and the procedure reports of these 648 biopsies and the final diagnoses of 637 PPLs to determine the diagnostic accuracy of ultrasound-guided PNB. Factors that influenced the diagnostic accuracy were assessed by analysis of the biopsy procedures, which were classified as diagnostic cases (true-positive and true-negative) and non-diagnostic cases (false-positive, false-negative and indeterminate). Statistical analyses of factors that related to patient demographic characteristics, lesion characteristics and biopsy details were performed to determine possible effects on diagnostic accuracy. Biopsies were successfully performed in all cases, and 11 patients underwent second biopsies for the same lesions. Among the 637 PPLs, there were 326 (51.2%) malignant lesions, 272 (42.7%) benign lesions and 39 (6.1%) indeterminate lesions. Of the 272 benign lesions, 114 (41.9%) were found to be tuberculous. The overall diagnostic accuracy was 81.8%, and the rates of hemoptysis, symptomatic pneumothorax and chest-tube insertion were 8.0%, 1.7% and 0.9%, respectively. Lesions sizes were divided into 3 groups according to the measurement by ultrasound. For lesions that measured ≤20 mm, 21-49 mm and ≥50 mm, the diagnostic accuracy was 72.0%, 86.8% and 79.7%, while sensitivity and specificity were 54.3%-79.2%, 88.3%-90.7% and 79.4%-89.5% and 77.3%-100%, 96.8%-100% and 58.6%-100%, respectively. Diagnostic accuracy was significantly affected by lesion size when lesion size was measured by ultrasound (p = 0.006) and computed tomography (CT) (p = 0.001). In the 3 lesion groups of ≤20 mm, 21-49 mm or ≥50 mm, diagnostic accuracy among each group was significantly different (p <0.001). When lesion size was measured by ultrasound (p <0.001) and CT (p <0.001) and the 3 groups were analyzed (p <0.001), there was a statistically significant relationship between lesion size and the presence of necrosis. The rates of the presence of necrosis in lesions that measured ≤20 mm, 21-49 mm and ≥50 mm were 3.9%, 11.7% and 28.8%, respectively. No significance was found for age (p = 0.119), gender (p = 0.25), lesion location (p = 0.55), the presence of necrosis (p = 0.226), patient position (p = 0.25), needle size (p = 0.26), puncture angle (p = 0.34) and needle passes (p = 0.21). Ultrasound-guided PNB is an effective and safe diagnostic method for PPLs; the diagnostic accuracy is significantly affected by lesion size and decreases in smaller (≤20 mm) and larger (≥50 mm) lesions.
Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Percutaneous needle biopsy; Peripheral pulmonary lesions; Ultrasound

Mesh:

Year:  2018        PMID: 29525458     DOI: 10.1016/j.ultrasmedbio.2018.01.016

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  8 in total

1.  Safety and efficacy of vacuum bottle plus catheter for drainage of iatrogenic pneumothorax.

Authors:  Shih-Yu Chen; Yao-Wen Kuo; Chao-Chi Ho; Huey-Dong Wu; Hao-Chien Wang
Journal:  BMC Pulm Med       Date:  2022-06-07       Impact factor: 3.320

2.  Comparison of the Value of Conventional Ultrasound and Contrast-Enhanced Ultrasound-Guided Puncture Biopsy in Different Sizes of Peripheral Pulmonary Lesions.

Authors:  Qi-Qin You; Shi-Yi Peng; Zhi-Ying Zhou; Xing-Li Tan; Xian-Sheng Miao
Journal:  Contrast Media Mol Imaging       Date:  2022-05-09       Impact factor: 3.009

3.  Hemoptysis complicating ultrasound-guided transthoracic needle lung biopsy: air bronchial sign is a risk predictor.

Authors:  Yuxin Zhang; Liantu He; Xinghua Zhou; Dazhi Zhou; Jiaxin Tang; Qing Tang
Journal:  J Thorac Dis       Date:  2020-06       Impact factor: 2.895

4.  Propensity-score-matching analysis to compare efficacy and safety between 16-gauge and 18-gauge needle in ultrasound-guided biopsy for peripheral pulmonary lesions.

Authors:  Weijun Huang; Jieyi Ye; Yide Qiu; Weiwei Peng; Ninghui Lan; Weizhen Cui; Ting Huang; Yinghui Ou; Yingjia Li
Journal:  BMC Cancer       Date:  2021-04-09       Impact factor: 4.430

5.  Ultrasound-guided lung biopsy with coaxial technique: pleural contact length affects the occurrence of pneumothorax after first puncture.

Authors:  Rinpei Imamine; Takeshi Kubo; Keizo Akuta; Hisato Kobayashi; Yoshiharu Yamamoto; Ayako Saito; Naoki Sakai; Tomoyuki Shirase
Journal:  Jpn J Radiol       Date:  2021-11-05       Impact factor: 2.374

6.  Application value of contrast-enhanced ultrasound in the diagnosis of peripheral pulmonary focal lesions.

Authors:  Zina Bai; Tong Liu; Wei Liu; Zhensheng Li; Hao Zheng; Xingbin Li
Journal:  Medicine (Baltimore)       Date:  2022-07-22       Impact factor: 1.817

7.  Septic pulmonary embolism in China: clinical features and analysis of prognostic factors for mortality in 98 cases.

Authors:  Jing Jiang; Qiu-Li Liang; Li-Hua Liu; Shuang-Qi Cai; Zhong-Ye Du; Jin-Liang Kong; Yi-Qiang Chen
Journal:  BMC Infect Dis       Date:  2019-12-27       Impact factor: 3.090

8.  Ultrasound-Guided Percutaneous Core Needle Biopsy of Peripheral Pulmonary Nodules ≤ 2 cm: Diagnostic Performance, Safety and Influence Factors.

Authors:  Weijun Huang; Jieyi Ye; Yide Qiu; Weiwei Peng; Ninghui Lan; Ting Huang; Yinghui Ou; Xiaoyun Deng; Yingjia Li
Journal:  Front Oncol       Date:  2021-05-14       Impact factor: 6.244

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.