| Literature DB >> 35611212 |
Wei Chen1, Li-Xiang Fang1, Hai-Lan Chen1, Jian-Hua Zheng2.
Abstract
BACKGROUND: Several studies have reported the prognostic value of ultrasound elastography (UE) in patients receiving neoadjuvant chemotherapy (NACT) for breast cancer. However, the assessment of parameters differed between shear-wave elastography and strain elastography in terms of measured elasticity parameter and mode of imaging. It is important, therefore, to assess the accuracy of the two modes of elastography. AIM: To assess the accuracy of UE for predicting the pathologic complete response (pCR) in breast cancer patients following NACT.Entities:
Keywords: Breast cancer; Chemotherapy; Meta-analysis; Ultrasonography validation studies
Year: 2022 PMID: 35611212 PMCID: PMC9048541 DOI: 10.12998/wjcc.v10.i11.3436
Source DB: PubMed Journal: World J Clin Cases ISSN: 2307-8960 Impact factor: 1.534
Figure 1Search strategy.
Characteristics of the included studies (n = 14)
|
|
|
|
|
|
|
|
|
|
|
| 1 | Evans | United Kingdom | Prospective | 64 | Patients with breast cancer receiving NACT | Shear wave elastography | Mean stiffness = 50 kPA | Assessment of any invasive cancer cells in the tumour bed at surgical resection after 6 cycles of NACT and an assessment of nodal metastases at axillary surgery | 52 |
| 2 | Evans | United Kingdom | Prospective | 80 | Patients with breast cancer receiving NACT | Shear wave elastography | Mean stiffness = 83 kPA | Assessment of any invasive cancer cells in the tumour bed at surgical resection after 6 cycles of NACT and an assessment of nodal metastases at axillary surgery | 53 |
| 3 | Falou | Canada | Prospective | 15 | Locally advanced breast cancer patients receiving NACT | Strain wave elastography | Mean strain ratio = 81 | Histopathological examination following mastectomy | 45 |
| 4 | Fang | China | Prospective | 60 | Breast cancer patients with stage IIa-IIIc (T1-T4; N0-N3; M0) and underwent surgery after receiving NACT | Strain wave elastography | Mean strain ratio = 5.4 | Pathological examination after surgical resection | 39 |
| 5 | Fernandes | Canada | Prospective | 92 | Patients with biopsy confirmed locally advanced breast cancer receiving NACT | Strain wave elastography | Elastography score = 4 | Histopathological examination | 55 |
| 6 | Hayashi | Japan | Retrospective | 55 | Histologically confirmed invasive breast cancer before NACT, and they underwent surgery after completion of NACT | Strain wave elastography | Elastography score = 4 | Pathologic response was assessed in surgical specimens of the breast with reference to the standards of the Japanese Breast Cancer Society | 52 |
| 7 | Jing | China | Prospective | 62 | Patients with diagnosis of breast carcinoma by ultrasound-guided core needle biopsy who received neoadjuvant chemotherapy followed by surgical excision | Shear wave elastography | Stiffness threshold-36.1% | Pathologic assessments involved a 2-step process. First, samples from core needle biopsies were examined to record the histologic and biologic characteristics of the tumours. These findings were usually combined with the clinical features of the patients to predict the response to neoadjuvant chemotherapy. Second, pathologic responses to neoadjuvant chemotherapy were evaluated according to the Miller-Payne grading criteria | 49 |
| 8 | Katyan | India | Prospective | 86 | TNM stage III and T3N0 subset of stage IIb breast cancer patients receiving NACT | Strain wave elastography | Strain ratio = 0.1 | Histopathological examination | NA |
| 9 | Lee | Korea | Retrospective | 71 | Women with stage II-III invasive breast cancers who received NACT | Shear wave elastography | Mean stiffness = 98.1 kPA | Histopathological examination | NA |
| 10 | Ma | China | Prospective | 71 | Women confirmed with invasive breast cancer by ultrasound guided core needle biopsy and underwent NACT and subsequent surgical excision | Shear and strain wave eastography | Stiffness threshold-30.4%; Strain ratio = 6.7 | Histopathological examination | 47.3 |
| 11 | Ma | China | Prospective | 43 | Breast cancer patients who were confirmed to be HER-2 positive by biopsy and puncture and underwent NACT | Shear wave elastography | Mean stiffness = 30 kPA | Histopathological examination after surgical resection | NA |
| 12 | Maier | Germany | Prospective | 134 | Histologically confirmed unilateral or bilateral breast cancer and indication for NACT | Shear wave elastography | Shear wave velocity = 3.35 | Pathological examinations and immunohistochemistry from the core-cut biopsy before and from the surgical specimen after NACT | 52.1 |
| 13 | Wang | China | Prospective | 65 | Patients confirmed | Strain wave elastography | Strain ratio = 8 | Histopathology results of the lesion samples isolated in the surgery were compared with those of the biopsy specimens obtained prior to treatment to determine the response to NACT | 48.3 |
| 14 | Zhang | China | Prospective | 91 | Patients diagnosed with invasive breast cancer by ultrasound-guided core needle biopsy and received NACT and subsequent surgical intervention | Shear wave elastography | Stiffness threshold–41.4% | Histopathological examination | 46.9 |
HER: Human epidermal growth factor receptor; kPA: Kilopascals; NA: Not available; NACT: Neoadjuvant chemotherapy; TNM: Tumour node metastasis.
Figure 2Quality assessment of the included studies based on quality assessment of diagnostic accuracy studies-2 tool (n = 19).
Figure 3Forest plot showing pooled sensitivity and specificity of ultrasound elastography for predicting pathological complete response following neoadjuvant chemotherapy amongst breast cancer patients. Q: Q statistic; df: Degree of freedom; I2: I2 statistic for heterogeneity; CI: Confidence interval.
Figure 4Summary receiver operator characteristic curve of ultrasound elastography for predicting pathological complete response following neoadjuvant chemotherapy amongst breast cancer patients.
Figure 5Likelihood scattergram of ultrasound elastography.
Figure 6Fagan nomogram of ultrasound elastography.
Figure 7Bivariate boxplot of the sensitivity and specificity of ultrasound elastography.
Figure 8Funnel plot for publication bias.
Figure 9Univariable and multivariable meta-regression results for ultrasound elastography for predicting pathological complete response following neoadjuvant chemotherapy amongst breast cancer patients. CI: Confidence interval.