Literature DB >> 35604674

Corrosion of orthodontic brackets: qualitative and quantitative surface analysis.

Romy A Doomen, Ivana Nedeljkovic, Reinder B Kuitert, Cornelis J Kleverlaan, Burcu Aydin.   

Abstract

OBJECTIVES: To determine and compare surface characteristics and presence of corrosion in new and used brackets with optical light microscopy (OLM) and scanning electron microscopy (SEM), and with elemental chemical analysis with energy-dispersive X-ray spectroscopy (EDS).
MATERIALS AND METHODS: OLM and SEM were used to analyze 24 new and 24 used conventional premolar brackets. EDS analysis was performed in six used brackets and four new brackets with corrosion-suspected spots.
RESULTS: OLM and SEM images showed wear/abfraction signs, striations, pits/crevices, and adherent material. Used brackets showed more deterioration than new brackets. SEM images disclosed more morphological features than OLM images. EDS analysis revealed a significantly higher phosphorus (P = .001) and sodium (P < .005) weight fraction and significantly lower amounts of chromium (P < .001) in used brackets. The iron, chromium, and nickel weight fractions did not differ significantly between the clean and corrosion-suspected spots. Of the corrosion-suspected spots analyzed by combined SEM and EDS, 44.14% and 6.90% remained corrosion-suspected on used and new brackets, respectively.
CONCLUSIONS: Used brackets showed more signs of corrosion than new ones. Combined assessment of SEM and EDS indicates that the bracket surface is affected during orthodontic treatment as a result of corrosion. © 0000 by The EH Angle Education and Research Foundation, Inc.

Entities:  

Keywords:  Brackets; Corrosion

Year:  2022        PMID: 35604674      PMCID: PMC9374347          DOI: 10.2319/072321-584.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.684


  24 in total

Review 1.  In vivo aging of orthodontic alloys: implications for corrosion potential, nickel release, and biocompatibility.

Authors:  Theodore Eliades; Athanasios E Athanasiou
Journal:  Angle Orthod       Date:  2002-06       Impact factor: 2.079

2.  Galvanic corrosion of metal injection molded (MIM) and conventional brackets with nickel-titanium and copper-nickel-titanium archwires.

Authors:  Barbara Siargos; Thomas G Bradley; Myrsini Darabara; George Papadimitriou; Spiros Zinelis
Journal:  Angle Orthod       Date:  2007-03       Impact factor: 2.079

3.  Morphological characterization of as-received and in vivo orthodontic stainless steel archwires.

Authors:  Julie Daems; Jean-Pierre Celis; Guy Willems
Journal:  Eur J Orthod       Date:  2009-02-02       Impact factor: 3.075

Review 4.  Corrosion of orthodontic appliances--should we care?

Authors:  Kate House; Friedrich Sernetz; David Dymock; Jonathan R Sandy; Anthony J Ireland
Journal:  Am J Orthod Dentofacial Orthop       Date:  2008-04       Impact factor: 2.650

5.  Nickel in dental plaque and saliva in patients with and without orthodontic appliances.

Authors:  Ronny Fors; Maurits Persson
Journal:  Eur J Orthod       Date:  2006-01-13       Impact factor: 3.075

6.  Physical, mechanical, and flexural properties of 3 orthodontic wires: an in-vitro study.

Authors:  Shubhaker Rao Juvvadi; Vignesh Kailasam; Sridevi Padmanabhan; Arun B Chitharanjan
Journal:  Am J Orthod Dentofacial Orthop       Date:  2010-11       Impact factor: 2.650

7.  Metal ion release from fixed orthodontic appliances--an in vivo study.

Authors:  Fariborz Amini; Alireza Jafari; Parviz Amini; Sepehr Sepasi
Journal:  Eur J Orthod       Date:  2011-02-08       Impact factor: 3.075

8.  Nickel content of as-received, retrieved, and recycled stainless steel brackets.

Authors:  Theodore Eliades; Spiros Zinelis; George Eliades; Athanasios E Athanasiou
Journal:  Am J Orthod Dentofacial Orthop       Date:  2002-08       Impact factor: 2.650

9.  Nickel content of as-received and retrieved NiTi and stainless steel archwires: assessing the nickel release hypothesis.

Authors:  Theodore Eliades; Spiros Zinelis; Moschos A Papadopoulos; George Eliades; Athanasios E Athanasiou
Journal:  Angle Orthod       Date:  2004-04       Impact factor: 2.079

10.  Mapping chemical elements on the surface of orthodontic appliance by SEM-EDX.

Authors:  Marcin Mikulewicz; Paulina Wołowiec; Izabela Michalak; Katarzyna Chojnacka; Wojciech Czopor; Adam Berniczei-Royko; Andras Vegh; Thomas Gedrange
Journal:  Med Sci Monit       Date:  2014-05-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.